English
Related papers

Related papers: Development and Performance Analysis of Glass-Base…

200 papers

This paper reports the latest developmental efforts for a position-sensitive glass-based Resistive Plate Chamber (RPC) and a multi-channel Data AcQuisition (DAQ) system tailored for muon tracking in muography applications. The designed…

Instrumentation and Detectors · Physics 2024-02-26 V. Kumar , S. Basnet , E. Cortina Gil , P. Demin , R. M. I. D. Gamage , A. Giammanco , R. Karnam , M. Moussawi , A. Samalan , M. Tytgat , A. Youssef

Muography is finding applications in various domains such as volcanology, archaeology, civil engineering, industry, mining, and nuclear waste surveys. To simplify transportation and installation in remote locations after laboratory testing,…

The use of conventional imaging techniques becomes problematic when faced with challenging logistics and confined environments. In particular, such scenarios are not unusual in the field of archaeological and mining explorations as well as…

Instrumentation and Detectors · Physics 2022-02-03 S. Basnet , E. Cortina Gil , P. Demin , R. M. I. D. Gamage , A. Giammanco , R. Karnam , M. Moussawi , A. Samalan , M. Tytgat

Muography (or muon radiography) is an imaging technique that relies on the use of cosmogenic muons as a free and safe radiation source. It can be applied in various fields such as archaeology, civil engineering, geology, nuclear reactor…

Resistive Plate Chambers (RPCs) are essential active media of large-scale experiments as part of the muon systems and (semi-)digital hadron calorimeters. Among the several outstanding issues associated with the RPCs, the loss of efficiency…

Instrumentation and Detectors · Physics 2023-07-19 Mehmet Tosun , Burak Bilki , Kutlu Kagan Sahbaz

Muon tomography or muography is an emerging imaging technique that uses cosmogenic muons as the radiation source. Due to its diverse range of applications and the use of natural radiation, muography is being applied across many fields such…

Instrumentation and Detectors · Physics 2022-02-02 R. M. I. D Gamage , S. Basnet , E. Cortina Gil , P. Demin , A. Giammanco , R. Karnam , M. Moussawi , M. Tytgat , .

Imaging techniques that use atmospheric muons, collectively named under the neologism "muography", have seen a tremendous growth in recent times, mainly due to their diverse range of applications. The most well-known ones include but are…

Instrumentation and Detectors · Physics 2020-12-09 S. Basnet , E. Cortina Gil , P. Demin , R. M. I. D. Gamage , A. Giammanco , M. Moussawi , M. Tytgat , S. Wuyckens

We report on the behaviour of Resistive Plate Chambers (RPC) developed for muon detection in ultra-high energy cosmic ray (UHECR) experiments. The RPCs were developed for the MARTA project and were tested on field conditions. These RPCs…

The phase-out of hydro-fluorocarbons, owing to their high Global Warming Power, affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluoroethane C$_2$H$_2$F$_4$, has increased operational difficulties on existing systems…

Instrumentation and Detectors · Physics 2024-03-01 A. Blanco , P. Fonte , L. Lopes , M. Pimenta

A new type of resistive plate chamber (RPC) is under development using thin-film resistive electrodes based on diamond-like carbon (DLC). Planned to be put on the path of high-intensity low-momentum muon beam of the MEG II experiment, this…

Instrumentation and Detectors · Physics 2022-12-21 Atsushi Oya , Kei Ieki , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Kensuke Yamamoto

This work reports a cost-effective, multi-parameter readout and data-acquisition system for a muon scattering tomography system based on Resistive Plate Chambers (RPCs). Initial test measurements with a prototype Resistive Plate Chamber…

Instrumentation and Detectors · Physics 2022-06-01 Subhendu Das , Sridhar Tripathy , Sandip Sarkar , Nayana Majumdar , Supratik Mukhopadhyay

We report on the first steps in the development of a small-size muon telescope based on glass Resistive Plate Chambers with small active area ($16\times 16~{\rm cm}^2$). The long-term goal of this project is to focus on applications of…

Instrumentation and Detectors · Physics 2018-12-19 Sophie Wuyckens , Andrea Giammanco , Pavel Demin , Eduardo Cortina Gil

Optimization of spacer and gas distribution inside glass resistive plate chamber (RPC) is reported. Simulation studies demonstrate improvements on the gas flow velocity homogeneity and lower vorticity inside the gas chamber. The optimized…

Instrumentation and Detectors · Physics 2022-01-05 L. Mao , F. Lagarde , J. Guo , X. Wang , J. Li , Q. Shen , J. Zhu , H. Yang

The Gas Gain Monitoring (GGM) system of the Resistive Plate Chamber (RPC) muon detector in the Compact Muon Solenoid (CMS) experiment provides fast and accurate determination of the stability in the working point conditions due to gas…

Large Resistive Plate Chamber systems have their roots in High Energy Physics experiments at the European Organization for Nuclear Research: ATLAS, CMS and ALICE, where hundreds of square meters of both trigger and timing RPCs have been…

Instrumentation and Detectors · Physics 2022-11-30 João Saraiva , Carlos Alemparte , Daniel Belver , Alberto Blanco , Juan Callón , Jose Collazo , Alfredo Iglesias , Luís Lopes

Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred picoseconds, along with spatial resolution on the order of a…

As part of the Compact Muon Solenoid experiment Phase-II upgrade program, new Resistive Plate Chambers will be installed in the forward region. High background conditions are expected in this region during the high-luminosity phase of the…

Instrumentation and Detectors · Physics 2020-06-02 Sabino Meola

The CMS experiment, located at the Large Hadron Collider (LHC) in CERN, has a redundant muon system composed by three different gaseous detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central…

Instrumentation and Detectors · Physics 2020-01-29 M. A. Shah , R. Hadjiska

The Multigap Resistive Plate Chambers (MRPCs) are gas ionization detectors with multiple gas sub-gaps made of resistive electrodes. The high voltage (HV) is applied on the outer surfaces of outermost resistive plates only, while the…

Instrumentation and Detectors · Physics 2016-12-16 Moon Moon Devi , Naba K. Mondal , B. Satyanarayana , R. R. Shinde

Primary cosmic rays when interact with our atmosphere, produce a cascade of lighter secondary particles namely pion, kaon, neutrons, muons, electrons, positrons and neutrinos. Muons are one of the most abundant and easily detectable…