Related papers: Broadband Optical Modulation and Control at Millik…
We investigate theoretically the possibility of using the cold-electron bolometer (CEB) as a counter for 1 cm wavelength (30 GHz) photons. To reduce the flux of photons from the environment, which interact with the detector, the bath…
Delivering on the revolutionary promise of a universal quantum computer will require processors with millions of quantum bits (qubits). In superconducting quantum processors, each qubit is individually addressed with microwave signal lines…
We present here a small-scale liquid Helium (LHe) immersion cryostat with an innovative optical setup suitable to work in long wavelength radiation ranges and under applied magnetic field. The cryostat is a multi stage device with several…
This paper presents the first experimental investigation and physical discussion of the cryogenic behavior of a commercial 28 nm bulk CMOS technology. Here we extract the fundamental physical parameters of this technology at 300, 77 and 4.2…
Current control techniques for cryogenically cooled qubits are realized with coaxial cables, posing multiple challenges in terms of cost, thermal load, size, and long-term scalability. Emerging approaches to tackle this issue include…
The electrical properties and performance characteristics of niobium dioxide (NbO$_\mathrm{2}$)-based memristive devices are examined at cryogenic temperatures. Sub-stoichiometric Nb$_\mathrm{2}$O$_\mathrm{5}$ was deposited via magnetron…
We consider mid-infrared (5 to 25 micrometers), optically cooled detectors based on a microcantilever sensor of the radiation pressure. A significant enhancement of sensitivity is achieved due the combination of low effective temperature…
Stimulated Brillouin scattering provides optical gain for efficient and narrow-linewidth lasers in high-Q microresonator systems. However, the thermal dependence of the Brillouin process, as well as the microresonator, impose strict…
A new instrument dedicated to the kinetic study of low-temperature gas phase neutral-neutral reactions, including clustering processes, is presented. It combines a supersonic flow reactor with Vacuum Ultra-Violet (VUV) synchrotron…
The temperature dependence of the pulse length was measured for an 18-fold segmented n-type germanium detector in the temperature range of 77-120 K. The interactions of 122 keV photons originating from a Europium-152 source were selected…
For low-temperature experiments such as liquid xenon dark matter detectors, it is crucial to read out detector signals from cryostats. Traditionally, photoelectrical signals are transmitted from the cryogenic region to the outside using…
We present an approach to fabrication and packaging of integrated photonic devices that utilizes waveguide and detector layers deposited at near-ambient temperature. All lithography is performed with a 365 nm i-line stepper, facilitating…
We have used a single-particle detector system, based on secondary electron emission, for counting low-energetic (~keV/u) massive products originating from atomic and molecular ion reactions in the electrostatic Cryogenic Storage Ring…
We report on a non-interacting technique for thermal characterization of fluids based on surface plasmon resonance interrogation. Using liquid volumes less than 20 micro liters we have determined the materials' thermo-optic coefficients…
We have developed a modular interconnect platform for the control and readout of multiple solid-state qubits at cryogenic temperatures. The setup provides 74 filtered dc-bias connections, 32 control and readout connections with a bandwidth…
To make precision measurements with a CsI(Tl) calorimeter in a high luminosity environment requires that the crystals are well calibrated and continually monitored for radiation damage. This should not effect the total integrated luminosity…
Displacement sensors have a variety of applications within gravitational wave detectors. The seismic isolation chain of the LIGO core optics utilises optical shadow sensors for their stabilisation. Future upgrades, such as LIGO Voyager,…
We report an experimental setup for simultaneously measuring specific heat and thermal conductivity in feedback-controlled pulsed magnetic fields of 50 msec duration at cryogenic temperatures. A stabilized magnetic field pulse obtained by…
A quasi-optical (QO) test bench was designed, simulated, and calibrated for characterizing S-parameters of devices in the 220-330 GHz (WR-3.4) frequency range, from room temperature down to 4.8 K. The devices were measured through vacuum…
A number of critical active and passive components of optical links have been tested at 77 K or lower temperatures, demonstrating potential development of optical links operating inside the liquid argon time projection chamber (LArTPC)…