Related papers: The Timepix4 Beam Telescope
The ZEUS Central Tracking Detector utilizes a time difference measurement to provide a fast determination of the z-coordinate of each hit. The z-by-timing measurement is achieved by using a Time-to-Amplitude Converter which has an intrinsic…
This paper reports results on a detailed study of charge collection and signal-to-noise performance of CMOS monolithic pixel sensors before and after back-thinning and their application in a pixel beam telescope for the ALS 1.5 GeV $e^-$…
The next generation of collider experiments require tracking detectors with extreme performance capabilities in terms of spatial resolution (tens of $\mu \text{m}$), radiation hardness ($10^{17}~1~$MeV n$_{eq}/$cm$^2$) and timing resolution…
The detective quantum efficiency (DQE) and normalised noise power spectrum (NNPS) of the Timepix4 hybrid pixel detector in event-driven mode in TEM have been measured at 100 kV and 200 kV. In a raw data readout mode, the zero-frequency DQE…
The sPHENIX detector to be installed at RHIC in 2022 is designed to precisely measure jets, jet correlations, and dilepton pairs in heavy-ion collisions. With these measurements in mind, sPHENIX will employ a compact TPC covering 20cm < r <…
Time-resolved photon-counting plays an indispensable role in precision metrology in both classical and quantum regimes. In particular, time-correlated single-photon counting (TCSPC) has been the key enabling technology for applications such…
We demonstrate temporal measurements of subpicosecond optical pulses via time-to-frequency conversion in a 45cm long CMOS compatible high index glass spiral waveguide. The measurements are based on efficient four wave mixing in the C-band,…
The combination of a Cherenkov radiator with a semi-transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolution of better than 15ps. While tileable prototypes with…
For the first time, a small dual-phase (liquid/gas) xenon time projection chamber was equipped with a top array of silicon photomultipliers for light and charge readout. Here we describe the instrument in detail, as well as the data…
The multi-sensory setups consisting of the laser scanners and cameras are popular as the measurements complement each other and provide necessary robustness for applications. Under dynamic conditions or when in motion, a direct…
We present the recent development of a lightweight detector capable of accurate spatial, timing, and amplitude resolution of charged particles. The technology is based on double-sided double-metal p+\,--\,n\,--\,n+ micro-strip silicon…
This article presents the timing performance of materials with fast light emission, tested as Minimum Ionizing Particle detectors using 150 GeV hadron beams in Monte Carlo simulations and at the CERN SPS North Area. Pixels of cross-section…
Beam tests using tracking telescopes are a standard method for determining the spatial resolution of detectors. This requires the precise knowledge of the position resolution of beam tracks reconstructed at the Device Under Test (DUT). A…
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget…
The time-resolved electron beam envelope parameters including sectional distribution and position are important and necessary for the study of beam transmission characteristics in the magnetic field and verifying the magnetic field setup…
3D silicon detectors are characterized by cylindrical electrodes perpendicular to the surface and penetrating into the bulk material in contrast to standard Si detectors with planar electrodes on its top and bottom. This geometry renders…
Thin planar pixel modules are promising candidates to instrument the inner layers of the new ATLAS pixel detector for HL-LHC, thanks to the reduced contribution to the material budget and their high charge collection efficiency after…
We present a detailed exposition of the design for time- and angle-resolved photoemission spectroscopy using a UV probe laser source that combines the nonlinear effects of \b{eta}-BaB2O4 and KBe2BO3F2 optical crystals. The photon energy of…
The time resolution for a charged particle detection is reported for a typical scintillating fiber detector instrumented with Rockwell HISTE-IV Visible Light Photon Counters. The resolution measurements are shown to agree with a simple…
A new, compact beam position monitor based on segmented a toroidal coil surrounding the charged particle beam has been investigated. It makes use of the induced voltages in the windings instead of the induced charge imbalance on capacitor…