Related papers: Positronium Imaging: History, Current Status, and …
Various concentrations (8{\div}300 mmol/L) of NaCl, KCl and NaCl + KCl aqueous solutions were investigated using the positron annihilation lifetime spectroscopy (PALS). A strong dependence of the o-Ps intensity as a function of solution…
The growing interest in human-grade total body positron emission tomography (PET) systems has also application in small animal research. Due to the existing limitations in human-based studies involving drug development and novel treatment…
We propose an innovative method for proton radiography based on nuclear emulsion film detectors, a technique in which images are obtained by measuring the position and the residual range of protons passing through the patient's body. For…
Positron emission tomography, like many other tomographic imaging modalities, relies on an image reconstruction step to produce cross-sectional images from projection data. Detection and localization of the back-to-back annihilation photons…
Theoretical positron lifetime values have been calculated systematically for most of the elements of the Periodic Table. Self-consistent and non-self-consistent schemes have been used for the calculation of the electronic structure in the…
Hyperfine spectroscopy of positronium formed in the presence of a static magnetic field is considered. Generalising the situation hitherto developed in the literature, the magnetic field is not assumed to be parallel to the momentum of…
Positron Annihilation Lifetime Spectroscopy (PALS) is a non-destructive radiological technique widely used in material science studies. PALS typically relies on an analog coincidence measurement setup and allows the estimate of the positron…
The scattering of ortho-positronium (Ps) by hydrogen atoms has been investigated in a five-state coupled-channel model allowing for Ps(1s)H(2s,2p) and Ps(2s,2p)H(1s) excitations using a recently proposed electron-exchange model potential.…
Enhanced-accuracy ion-range verification in real time shall enable a significant step forward in the use of therapeutic ion beams. Positron-emission tomography (PET) and prompt-gamma imaging (PGI) are two of the most promising and…
Positron Emission Tomography (PET) enables functional imaging of deep brain structures, but the bulk and weight of current systems preclude their use during many natural human activities, such as locomotion. The proposed long-term solution…
Single-shot positron annihilation lifetime spectroscopy (SSPALS) is an extremely useful tool for experiments involving the positronium atom (Ps). I examine some of the methods that are typically employed to analyze lifetime spectra, and use…
Diagrammatic many-body theory is used to calculate the scattering phase shifts, normalized annihilation rates $Z_{\rm eff}$ and annihilation gamma spectra for positron collisions with the hydrogen-like ions He$^+$, Li$^{2+}$, B$^{4+}$ and…
Positron emission tomography (PET) imaging is widely used in a number of clinical applications, including cancer and Alzheimer's disease (AD) diagnosis, monitoring of disease development, and treatment effect evaluation. Statistical…
In this paper we present prospects for using the J-PET detector to search for discrete symmetries violations in a purely leptonic system of the positronium atom. We discuss tests of CP and CPT symmetries by means of ortho-positronium decays…
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the…
Verification of patient specific proton stopping powers obtained in the patient treatment position can be used to reduce the distal margins needed in particle beam planning. Proton radiography can be used as a pre-treatment instrument to…
Time-of-Flight Positron Emission Tomography is a medical imaging technique, based on the detection of two back-to-back {\gamma}-photons generated from radiotracers injected in the body. Its limit is the ability of employed scintillation…
Treatment planning systems at proton-therapy centres generally use X-ray computed tomography (CT) as primary imaging technique to infer the proton treatment doses to tumour and healthy tissues. However, proton stopping powers in the body,…
Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance in the Universe. We report the most precise test of P, T and CP invariance in decays of ortho-positronium,…
Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and…