Related papers: A continuously-cooled 3He/4He phase separation ref…
In this article we summarize experimental work on cryogen-free 3He/4He dilution refrigerators which, in addition to the dilution refrigeration circuit, are equipped with a 4He-1K-stage. This type of DR becomes worth considering when high…
We present a 3He / 4He dilution refrigerator designed for cooling astronomical mm-wave telescope receivers to around 100 mK. Used in combination with a Gifford-McMahon closed-cycle refrigerator, 4He and 3He sorption-pumped refrigerators,…
We describe the preparation of ultra cold atomic clouds in a dilution refrigerator. The closed cycle 3He/4He cryostat was custom made to provide optical access for laser cooling, optical manipulation and detection of atoms. We show that the…
He-3/He-4 dilution refrigerators (DR) are very common in sub-Kelvin temperature research. We describe a pulse tube precooled DR where a separate He-4 circuit condenses the He-3 of the dilution loop. Whereas in our previous work the dilution…
At the Walther-Mei{\ss}ner-Institut (WMI), a new cryogen-free 3He/4He dilution refrigerator (DR) has been completed; the cryostat will be employed to cool experiments on superconducting quantum circuits for quantum information technology…
This paper presents a three-stage continuous adiabatic demagnetization refrigerator (CADR) simultaneously providing cooling platforms at two different temperatures. Unlike conventional CADR with two continuous stages, this system does not…
Experiments performed at a temperature of a few millikelvin require effective thermalization schemes, low-pass filtering of the measurement lines and low-noise electronics. Here, we report on the modifications to a commercial dilution…
We propose a solid state refrigeration technique based on repeated adiabatic magnetization/demagnetization cycles of a superconductor which acts as the working substance. The gradual cooling down of a substrate (normal metal) in contact…
We report on the development of a versatile cryogen-free laboratory cryostat based upon a commercial pulse tube cryocooler. It provides enough cooling power for continuous recondensation of circulating $^4$He gas at a condensation pressure…
An unconventional method of continuous solid-state cryogenic cooling utilizing the electron subband degeneracy of semiconductor heterostructures is proposed in this Letter. An electrostatic heat pump is modeled, which employs subband…
We have developed low temperature part of an ultra high vacuum scanning probe microscope (UHV-SPM) working at variable temperature within the range from 20 K to 700 K. To achieve the required temperature range, a flow cooling system using…
We developed a cryogenic system on a rotating table that achieves sub-Kelvin conditions. The cryogenic system consists of a helium sorption cooler and a pulse tube cooler in a cryostat mounted on a rotating table. Two rotary-joint…
We present a simple layout of a fast cooling system for liquids in sealed containers utilizing the large temperature gradients of cold nitrogen gas. Our system is optimized for about 20 cylindrical containers of 500 cm3 but the setup allows…
A two-stage Stirling-type U-shape pulse tube cryocooler driven by a 10 kW-class linear compressor was designed, built and tested. A special feature of the cold head is the absence of a heat exchanger at the cold end of the first stage,…
We studied a novel cooling method, in which $^3$He and $^4$He are mixed at the $^4$He crystallization pressure at temperatures below $0.5\,\mathrm{mK}$. We describe the experimental setup in detail, and present an analysis of its…
Access to lower temperatures has consistently enabled scientific breakthroughs. Pushing the limits of \emph{on-chip} temperatures deep into the microkelvin regime would open the door to unprecedented quantum coherence, novel quantum states…
A 3He sorption cooler produced the operational temperature of 285mK for the bolometer arrays of the Photodetector Array Camera and Spectrometer (PACS) instrument of the Herschel Space Observatory. This cooler provided a stable hold time…
We describe a helium evaporation refrigerator used to cool dynamically polarized proton and deuteron targets for electron-scattering experiments using the CEBAF Large Acceptance Spectrometer CLAS12 at Jefferson Lab. The geometry of the…
A Kelvinox 400 dilution refrigerator with the ability to load samples onto the mixing chamber from the bottom of the cryostat has been combined with an ultrahigh-vacuum (UHV) deposition chamber equipped with molecular beam sources. The…
We report experimental demonstration of the feasibility of reaching temperatures below 1 mK using cryogen-free technology. Our prototype system comprises an adiabatic nuclear demagnetisation stage, based on hyperfine-enhanced nuclear…