Related papers: Characterization of the SiPiC Payload for Photon D…
AstroPix is a high-voltage CMOS (HV-CMOS) monolithic active pixel sensor originally developed to enable precision gamma-ray imaging and spectroscopy in the medium-energy regime (approximately 100 keV-100 MeV) based on the groundwork laid by…
The use of silicon photomultipliers (SiPMs) in imaging atmospheric Cherenkov telescopes is expected to extend the observation times of very-high-energy gamma-ray sources, particularly within the highest energy domain of 50-300 TeV, where…
Balloon- and space-borne cosmic-ray experiments employ plastic scintillators read out by silicon photomultipliers (SiPMs) to achieve picosecond-level time resolutions for triggering and particle identification. The performance of these…
Silicon photomultipliers (SiPMs) have a low radioactivity, compact geometry, low operation voltage, and reasonable photo-detection efficiency for vacuum ultraviolet light (VUV). Therefore it has the potential to replace photomultiplier…
We present the development of a novel 11328 pixel silicon photomultiplier (SiPM) camera for use with a ground-based Cherenkov telescope with Schwarzschild-Couder optics as a possible medium-sized telescope for the Cherenkov Telescope Array…
A Cosmic Muon Veto (CMV) detector using extruded scintillators is being designed around the mini-Iron Calorimeter detector at the transit campus of the India-based Neutrino Observatory at Madurai for measuring its efficiency at shallow…
Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle…
Single Photon Emission Computed Tomography (SPECT) scanners based on photomultiplier tubes (PMTs) are still largely employed in the clinical environment. A standard camera for full-body SPECT employs $\sim50$-100 PMTs of 4-8~cm diameter and…
A prototype of a position sensitive photo-detector with 5.6 x 5.6 cm2 detection area readout with 64 Hamamatsu MPPCs (S10931-100P) with 3 x 3 mm2 active area each has been built and tested. The photo-sensors are arranged in a 8 x 8 array…
Silicon-based photosensors (SiPMs) working in the Geiger-mode represent an elegant solution for the readout of particle detectors working at low-light levels like Cherenkov detectors. Especially the insensitivity to magnetic fields makes…
The observation of the low-energy $\gamma$-ray (0.1-30 MeV) sky has been significantly limited since the COMPTEL instrument was decommissioned aboard the Compton Gamma-ray Observer (CGRO) satellite in 2000. The exploration of $\gamma$-ray…
The CMS Outer Hadron Calorimeter (HO) is the first large-scale hadron collider detector to use Silicon Photomultipliers (SiPMs). To build the system we installed and characterized 3000 SiPMs of which 1656 channels of SiPMs with 40MHz…
Large-area silicon photomultipliers (SiPMs) are desired in many applications where large surfaces have to be covered. For instance, a large area SiPM has been developed by Hamamatsu Photonics in collaboration with the University of Geneva,…
This study investigates the characteristics of Silicon Photomultipliers (SiPMs) with different pixel densities, focusing on their response across a wide dynamic range. Using an experimental setup that combines laser source and…
Silicon photo-multipliers (SiPM) have been replacing traditional photomultiplier tubes in most light sensing applications. However, when large detection surface coverage is needed, photomultipliers (PMTs) are still the preferred choice. The…
Silicon photomultipliers (SiPMs) are photosensors widely used for imaging in a variety of high energy and nuclear physics experiments. In noble-gas detectors for double-beta decay and dark matter experiments, SiPMs are attractive…
Silicon PhotoMultipliers (SiPM) are an excellent choice for the scintillator light readout at hadron calorimeters due to their insensitivity to magnetic fields, low operating voltages, low cost, compactness and mechanical endurance. They…
The Space Interferometry Mission PlanetQuest Light (or SIM-Lite) is a new concept for a space borne astrometric instrument, to be located in a solar Earth-trailing orbit. SIM-Lite utilizes technology developed over the past ten years for…
The Solar Diameter Imager and Surface Mapper (SODISM) on board the PICARD space mission provides wide-field images of the photosphere and chromosphere of the Sun in five narrow pass bands (centered at 215.0, 393.37, 535.7, 607.1, and 782.2…
The possibility to build a SiPM-readout muon detector (SiRO), using plastic scintillators with optical fibers as sensitive volume and readout by SiPM photo-diodes, is investigated. SiRO shall be used for tracking cosmic muons based on…