English
Related papers

Related papers: A compact unshielded optically-pumped magnetic gra…

200 papers

We realise an intrinsic optically pumped magnetic gradiometer based on non-linear magneto-optical rotation. We show that our sensor can reach a gradiometric sensitivity of 18 $\text{fT}/\text{cm}/\sqrt{\text{Hz}}$ and can reject common mode…

In this work, we report the development of a rubidium-based single-beam scalar optically pumped magnetometer (OPM) and demonstrate its application in measuring human cardiac magnetic fields in an unshielded environment. The developed…

Statistical Mechanics · Physics 2026-02-17 Kushal Patel , Kesavaraja C , Pranab Dutta , Korak Biswas

To address the demands in healthcare and industrial settings for spatially resolved magnetic imaging, we present a modular optically pumped magnetometer (OPM) system comprising a multi-sensor array of highly sensitive quantum magnetometers.…

We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60…

Instrumentation and Detectors · Physics 2017-02-14 Dong Sheng , Abigail R. Perry , Sean P. Krzyzewski , Shawn Geller , John Kitching , Svenja Knappe

We demonstrate the sensitivity of a sensor based on an optically-pumped radio-frequency (RF) atomic magnetometer to the polarization state of the detected RF magnetic field, and measure $>$36 dB difference in amplitude sensitivity for…

Atomic Physics · Physics 2019-02-13 Vladislav Gerginov

We demonstrate a portable all-optical intrinsic scalar magnetic gradiometer composed of miniaturized cesium vapor cells and vertical-cavity surface-emitting lasers (VCSELs). Two cells, with an inner dimension of 5 mm x 5 mm x 5 mm and…

Atomic Physics · Physics 2020-04-10 Rui Zhang , Rahul Mhaskar , Ken Smith , Mark Prouty

Optically pumped atomic magnetometers (OPMs) offer highly sensitive magnetic measurements using compact hardware, offering new possibilities for practical precision sensors. Double-resonance OPM operation is well suited to unshielded…

We present a novel approach allowing an optically pumped magnetometer (OPM) to be operated within Earth's magnetic field as a vector magnetometer whose sensitive axis can be freely defined. This approach enables the measurement of any…

Instrumentation and Detectors · Physics 2024-08-20 Thomas Schönau , Theo Scholtes , Florian Wittkämper , Alexander Sekels , Stefan Hiebel , Gregor Oelsner , Ronny Stolz

Electrically conductive objects can be detected using the principle of electromagnetic induction where a primary oscillating magnetic field induces eddy currents in the object, which in turn produce a secondary magnetic field that can be…

Applied Physics · Physics 2022-12-06 L. M. Rushton , T. Pyragius , A. Meraki , L. Elson , K. Jensen

Optically detected magnetic resonance (ODMR) is an efficient mechanism to readout the spin of solid-state color centers at room temperature, thus enabling spin-based quantum sensors of magnetic field, electric field, and temperature with…

Materials Science · Physics 2023-06-22 Jialun Luo , Yifei Geng , Farhan Rana , Gregory D. Fuchs

Optically pumped magnetometers (OPMs) are compact and lightweight sensors that can measure magnetic fields generated by current flow in neuronal assemblies in the brain. Such sensors enable construction of magnetoencephalography (MEG)…

Optically detected magnetic resonance (ODMR) provides ultrasensitive means to detect and image a small number of electron and nuclear spins, down to the single spin level with nanoscale resolution. Despite the significant recent progress in…

Mesoscale and Nanoscale Physics · Physics 2015-06-23 Aharon Blank , Guy Shapiro , Ran Fischer , Paz London , David Gershoni

Cardiomagnetometry is a growing field of noninvasive medical diagnostics that has triggered a need for affordable high-sensitivity magnetometers. Optical pumping magnetometers are promising candidates satisfying that need since it was…

Medical Physics · Physics 2009-11-10 Georg Bison , Robert Wynands , Antoine Weis

We present a method for absolute calibration of received radio-frequency in the ultra low frequency (ULF), and very low frequency (VLF) range. This is achieved with the use of a radio frequency optically pumped magnetometer (RF-OPM). We…

Optically pumped magnetometers (OPMs) have demonstrated significant potential in weak magnetic field detection due to their high sensitivity. In this study, we developed an Mz-type optically pumped rubidium magnetometer using a…

Atomic Physics · Physics 2026-04-06 Zhengyu Su , Yang Li , Yongbiao Yang , Yanhua Wang , Jun He , Junmin Wang

Combined microwave-optical pump-probe methods are emerging to study the quantum state of spin qubit centers and the charge dynamics in semiconductors. A major hindrance is the limited bandwidth of microwave irradiation/detection circuitry…

Applied Physics · Physics 2020-10-27 S. Kollarics , A. Bojtor , K. Koltai , B. G. Márkus , K. Holczer , J. Volk , G. Klujber , M. Szieberth , F. Simon

Damage in infrastructure is often hidden until it becomes costly or dangerous. Common examples include corrosion under insulation, early fatigue damage in steel, corrosion of embedded reinforcement, and abnormal current flow in batteries…

Applied Physics · Physics 2026-04-07 Muhammad Mahmudul Hasan , Ingrid Torres , Alex Krasnok

We describe an array of spin-exchange relaxation free optical magnetometers designed for detection of fetal magnetocardiography (fMCG) signals. The individual magnetometers are configured with a small volume with intense optical pumping,…

Atomic Physics · Physics 2012-07-25 Robert Wyllie , Matthew Kauer , Ronald T. Wakai , Thad G. Walker

We present the development and performance of an optically detected magnetic resonance (ODMR) spectrometer. The spectrometer represents advances over similar instruments in three areas: i) the exciting light is a tunable laser source which…

Instrumentation and Detectors · Physics 2017-02-07 M. Negyedi , J. Palotás , B. Gyüre , S. Dzsaber , S. Kollarics , P. Rohringer , T. Pichler , F. Simon

Atomic magnetometers (AMs) offer many advantages over superconducting quantum interference devices (SQUIDs) due to, among other things, having comparable sensitivity while not requiring cryogenics. One of the major limitations of AMs is the…

Instrumentation and Detectors · Physics 2019-09-04 I. A. Sulai , Z. J. DeLand , M. D. Bulatowicz , C. P. Wahl , R. T. Wakai , T. G. Walker
‹ Prev 1 2 3 10 Next ›