Related papers: High-Q non-invasive Glucose Sensor using Microstri…
Noninvasive, non-contact and \textit{in vivo} monitoring of blood glucose is a long needed pathology tool for saving patients from recurring pain and hassle that can accompany conventional blood glucose testing methods. Optical coherence…
Diabetes mellitus is a growing global health issue, with Type 1 Diabetes (T1D) requiring constant monitoring to avoid hypoglycemia. Although Continuous Glucose Monitors (CGMs) are effective, their cost and invasiveness limit access,…
Miniaturized spectrometers hold great promise for in situ, in vitro, and even in vivo sensing applications. However, their size reduction imposes vital performance constraints in meeting the rigorous demands of spectroscopy, including fine…
We developed a scalable, label-free all-electronic sensor for D-glucose based on a carbon nanotube transistor functionalized with pyrene-1-boronic acid. This sensor responds to glucose in the range 1 uM - 100 mM, which includes typical…
Devices based on photonic integrated circuits play a crucial role in the development of low-cost, high-performance, industry-scale manufacturable sensors. We report the design, fabrication, and application of a silicon nitride…
To best of the authors knowledge, this article presents the first-ever non-invasive glucometer that takes into account serum glucose for high accuracy. In case of blood glucose measurement, serum glucose value has always been considered…
We demonstrate novel instrumentation for spontaneous Raman spectroscopy in biofluids, enabling development of a portable, automated, reliable diagnostics technique requiring minimal operator expertise to quantify disease markers. Label-free…
Silicon nanochannel biological field effect transistors have been developed for glucose detection. The device is nanofabricated from a silicon-on-insulator wafer with a top-down approach and surface functionalized with glucose oxidase. The…
We propose a new label-free ultrasonic sensor, which comprises a slot wave-guide and double silicon-on-insulator (SOI) slot micro-ring resonators. The all-optical sensors do not suffer from electromagnetic interference. We choose to…
This work demonstrates a non-contact diffuse reflectance approach with a working distance of ~1.1 meters for the potential of glucose sensing. Non-contact diffuse reflectance over 1.1-1.3 micrometers was developed according to a…
Glucose monitoring plays a critical role in managing diabetes, one of the most prevalent diseases globally. The development of fast-responsive, cost-effective, and biocompatible glucose sensors is essential for improving patient care. In…
A multichannel thin-film sensor is implemented from a set of microstrip-coupled split-ring resonators (SRR's) with different dimensions. Each SRR exhibits a unique high-Q resonance that is sensitive to the presence of a sample in a…
Diabetes is a prevalent chronic condition that compromises the health of millions of people worldwide. Minimally invasive methods are needed to prevent and control diabetes but most devices for measuring glucose levels are invasive and not…
Several centimeters below the skin lie multiple biomarkers, such as glucose, oxygenation, and blood flow. Monitoring these biomarkers regularly and in a non-invasive manner would enable early insight into metabolic status and vascular…
In this work, the blood NIR absorbances are recorded using the FT-IR method. It is shown that when the absorbance curves are multiplied by the first derivative of the water absorbance spectrum as well as by the first derivative of the…
A highly sensitive refractive index sensor based on grating-assisted strip waveguide directional coupler is proposed. The sensor is designed using two coupled asymmetric strip waveguides with a top-loaded grating structure in one of the…
In the world today, diabetic complications are a major factor in the disease's high mortality rate. Diabetes mellitus has been a major source of concern for decades due to its global prevalence and the resulting rising costs to individuals,…
A new approach for continuous and non-invasive monitoring of the glucose concentration in human epidermis has been suggested recently. This method is based on photoacoustic (PA) analysis of human interstitial fluid. The measurement can be…
Diabetes is a serious chronic metabolic disease. In the recent years, more and more consumer technology enterprises focusing on human health are committed to implementing accurate and non-invasive blood glucose algorithm in their products.…
Diabetes is a chronicle disease where the body of a human is irregular to dissolve the blood glucose properly. The diabetes is due to lack of insulin in human body. The continuous monitoring of blood glucose is main important aspect for…