English
Related papers

Related papers: The Sliding Flux Ramp Demodulation Algorithm with …

200 papers

A technological milestone for experiments employing Transition Edge Sensor (TES) bolometers operating at sub-kelvin temperature is the deployment of detector arrays with 100s--1000s of bolometers. One key technology for such arrays is…

Due to the periodic characteristics of SQUIDs, a suitable linearization technique is required for SQUID-based readout. Flux-ramp modulation is a common linearization technique and is typically applied for the readout of a…

Signal Processing · Electrical Eng. & Systems 2022-10-05 N. Karcher , T. Muscheid , T. Wolber , D. Richter , C. Enss , S. Kempf , O. Sander

The Microwave SQUID Multiplexer ({\mu}MUX) is the device of choice for the readout of a large number of Low-Temperature Detectors in a wide variety of experiments within the fields of astronomy and particle physics. While it offers large…

Digital Frequency-Domain Multiplexing (DfMux) is a technique that uses MHz superconducting resonators and Superconducting Quantum Interference Device (SQUID) arrays to read out sets of Transition Edge Sensors. DfMux has been used by several…

The deployment of large cryogenic detector arrays, comprising hundreds to thousands of individual detectors, is highly beneficial for various cutting-edge applications, requiring large statistics, angular resolution or imaging capabilities.…

Instrumentation and Detectors · Physics 2025-09-10 M. Neidig , T. Muscheid , R. Gartmann , L. E. Ardila Perez , M. Wegner , O. Sander , S. Kempf

The Transition-Edge Sensors (TES) is a mature, high-resolution x-ray spectrometer technology that provides a much higher efficiency than dispersive spectrometers such as gratings and crystal spectrometers. As larger arrays are developed,…

Instrumentation and Detectors · Physics 2018-06-08 K. D. Irwin , S. Chaudhuri , H. -M. Cho , C. Dawson , S. Kuenstner , D. Li , C. J. Titus , B. A. Young

We present a hybrid microwave SQUID multiplexer that combines two frequency-division multiplexing techniques to allow multiplexing a given number of cryogenic detectors with only a fraction of frequency encoding resonators. Similar to…

Instrumentation and Detectors · Physics 2022-05-04 Constantin Schuster , Mathias Wegner , Christian Enss , Sebastian Kempf

A digital frequency multiplexing (DfMUX) system has been developed and used to tune large arrays of transition edge sensor (TES) bolometers read out with SQUID arrays for mm-wavelength cosmology telescopes. The DfMUX system multiplexes the…

Instrumentation and Methods for Astrophysics · Physics 2015-05-14 K. MacDermid , P. Hyland , F. Aubin , E. Bissonnette , M. Dobbs , J. Hubmayr , G. Smecher , S. Warraich

The microwave SQUID multiplexer (umux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial…

In this work, we report the experimental readout results of a {\mu}MUX device using a Direct-RF SDR prototype based on the ZCU216 Radio-Frequency System-on-Chip (RFSoC) evaluation board. First, the analog performance of the SDR system was…

Frequency domain multiplexing (fMux) is an established technique for the readout of transition-edge sensor (TES) bolometers in millimeter-wavelength astrophysical instrumentation. In fMux, the signals from multiple detectors are read out on…

Digital frequency multiplexing (dfMux) is a readout architecture for transition edge sensor-based detector arrays and is used on telescopes including SPT-3G, POLARBEAR-2, and LiteBIRD. Here, we present recent progress and plans for…

Instrumentation and Methods for Astrophysics · Physics 2018-07-17 Amy E. Lowitz , Amy N. Bender , Matthew A. Dobbs , Adam J. Gilbert

At SRON we have been developing X-ray TES micro-calorimeters as backup technology for the X-ray Integral Field Unit (X-IFU) of the Athena mission, demonstrating excellent resolving powers both under DC and AC bias. We also developed a…

Instrumentation and Methods for Astrophysics · Physics 2025-06-04 D. Vaccaro , H. Akamatsu , L. Gottardi , M. de Wit , M. P. Bruijn , J. van der Kuur , K. Nagayoshi , E. Taralli , K. Ravensberg , J. R. Gao , J. W. A. den Herder

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at $\sim$10 mK, are usually…

The readout system with a high multiplexing ratio has become a bottleneck limiting the application of large-scale Transition Edge Sensor (TES) detector arrays. In recent years, the microwave superconducting quantum interference device…

We report on the development and demonstration of a MHz frequency domain multiplexing (FDM) technology to read out arrays of cryogenic transition edge sensor (TES) X-ray microcalorimeters. In our FDM scheme, TESs are AC-biased at different…

Large arrays of cryogenic detectors, including transition-edge sensors (TESs) or magnetic micro-calorimeters (MMCs), are needed for future experiments across a wide range of applications. Complexities in integration and cryogenic wiring…

Instrumentation and Detectors · Physics 2020-01-10 C. Yu , A. Ames , S. Chaudhuri , C. Dawson , K. D. Irwin , S. E. Kuenstner , D. Li , C. J. Titus

Arrays of low-temperature microcalorimeters provide a promising technology for X-ray astrophysics: the imaging spectrometer. A camera with at least several thousand pixels, each of which has an energy-resolving power ($E/\Delta…

Instrumentation and Methods for Astrophysics · Physics 2022-09-14 H. Akamatsu , W. B. Doriese , J. A. B. Mates , B. D. Jackson

Microwave frequency domain multiplexing is a suitable technique to read out a large number of detector channels using only a few connecting lines. In the HOLMES experiment this is based on inductively coupled rf-SQUIDs (Superconducting…

Instrumentation and Detectors · Physics 2018-02-28 P. Carniti , L. Cassina , M. Faverzani , E. Ferri , A. Giachero , C. Gotti , M. Maino , A. Nucciotti , G. Pessina , A. Puiu

Recent advances in the development of cryogenic particle detectors such as magnetic microcalorimeters (MMCs) allow the fabrication of sensor arrays with an increasing number of pixels. Since these detectors must be operated at the lowest…

Instrumentation and Detectors · Physics 2025-10-22 T. Muscheid , R. Gartmann , N. Karcher , F. Schuderer , M. Neidig , L. E. Ardila-Perez , M. Balzer , S. Kempf , O. Sander
‹ Prev 1 2 3 10 Next ›