English
Related papers

Related papers: First experimental proof of PET imaging based on m…

200 papers

The 64-channel Multianode Photo Multiplier (MaPMT) has been evaluated as a candidate for the LHCb Ring Imaging Cherenkov (RICH) photo detectors. We present result from data taken with a 3x3 array of closely packed MaPMTs mounted onto the…

High Energy Physics - Experiment · Physics 2009-11-10 F. Muheim

In positron emission tomography (PET), time-of-flight (TOF) information localizes source positions along lines of response. Cherenkov-radiator-integrated microchannel-plate photomultiplier tubes have achieved 30 ps TOF resolution,…

The aim of this work is to develop high precision Time-of-Flight (TOF) devices based on high refractive index solid Cherenkov radiators read out by silicon photomultipliers (SiPMs). Cherenkov light is prompt and therefore ideal for reaching…

We study the possibility to use the Cherenkov light for the efficient detection of 511 keV photons with the goal to use it in TOF-PET. We designed and tested two detection modules consisting of PbF$_2$ crystals attached to Planacon MCP-PMT…

Instrumentation and Detectors · Physics 2020-03-24 C. Canot , M. Alokhina , P. Abbon , J. P. Bard , D. Breton , E. Delagnes , J. Maalmi , G. Tauzin , D. Yvon , V. Sharyy

Positron emission tomography (PET) is the most sensitive biomedical imaging modality for non-invasively detecting and visualizing positron-emitting radiopharmaceuticals within a subject. In PET, measuring the time-of-flight (TOF)…

Instrumentation and Detectors · Physics 2024-10-17 Minseok Yi , Daehee Lee , Alberto Gola , Stefano Merzi , Michele Penna , Jae Sung Lee , Simon R. Cherry , Sun Il Kwon

Photosensitive gaseous detectors with a simple photoelectron multiplication mechanism as resistive plate chambers are expected to offer both large photo coverage and excellent time resolution while keeping costs low. We have developed a…

Instrumentation and Detectors · Physics 2025-02-25 R. Okubo , K. Matsuoka , T. Iijima , K. Inami , Y. Horii , K. Suzuki , K. Sumi , T. Ichikawa , K. Ueda , S. Koji , A. Kondo , K. Chiba

Time-of-flight positron emission tomography (TOF-PET) detectors exhibiting multiple coincidence time resolution (CTR) components, such as those induced by the mixing of Cherenkov and scintillation photons, have attracted increasing…

Medical Physics · Physics 2026-05-29 Kibo Ote , Fumio Hashimoto , Yuya Onishi , Ryosuke Ota , Maxime Toussaint , Francis Loignon-Houle

In the present work we describe the design, construction, and testing of the optical prototype developed for the BOLDPET project, with the objective of creating a PET detection module with high spatial and time resolution. The BOLDPET…

With the newly gained interest in the time of flight method for positron emission tomography (TOF-PET), many options for pushing the time resolution to its borders have been investigated. As one of these options the exploitation of the…

Instrumentation and Detectors · Physics 2015-06-16 S. E. Brunner , L. Gruber , J. Marton , K. Suzuki , A. Hirtl

The multi-Photomultiplier Tube (mPMT) photosensors will be used in the Water Cherenkov Test Experiment (WCTE) to efficiently detect the photons produced in the whole detector. One of the aims behind the development of WCTE is to test the…

Due to their very fast signal rise time in the order of 1 ns, Silicon-Photomultipliers have become of increasing interest for many experiments that require very good timing resolution. With the prospect of an application in medical imaging…

Instrumentation and Detectors · Physics 2019-05-01 Reimund Bayerlein , Ivor Fleck , Todd Peterson , Albert H. Walenta

In this work, we present a novel compact particle identification (PID) detector concept based on Silicon Photomultipliers (SiPMs) optimized to perform combined Ring-Imaging Cherenkov (RICH) and Time-of-Flight (TOF) measurements using a…

Instrumentation and Detectors · Physics 2026-01-22 M. N. Mazziotta , L. Congedo , G. De Robertis , M. Giliberti , F. Licciulli , A. Liguori , L. Lorusso , N. Nicassio , G. Panzarini , R. Pillera

A first experimental test of tracking relativistic charged particles by `drifting' Cherenkov photons in a water-based optical time-projection chamber (OTPC) has been performed at the Fermilab Test Beam Facility. The prototype OTPC detector…

Instrumentation and Detectors · Physics 2016-02-17 E. Oberla , H. J. Frisch

A novel photodetector based on a MCP-PMT vacuum tube with encapsulated CMOS ASIC has been tested at the CERN SPS high energy hadron beam, allowing single photon Cherenkov detection operating at 10$^4$ gain and with timing resolution of…

We have developed an accurate simulation model of the large 9 inch photomultiplier tubes (PMT) used in water-Cherenkov detectors of cosmic-ray induced extensive air-showers. This work was carried out as part of the development of the…

Instrumentation and Detectors · Physics 2014-11-20 Alexandre Creusot , Darko Veberic

Dedicated R&D efforts are currently underway to couple a thin Cherenkov radiator to Silicon Photomultiplier (SiPM) arrays for precise charged particle Time-of-Flight (ToF) measurements. The prompt nature of Cherenkov radiation makes it an…

Instrumentation and Detectors · Physics 2026-01-22 M. N. Mazziotta , A. Di Mauro , M. Giliberti , A. Liguori , L. Lorusso , E. Nappi , N. Nicassio , G. Panzarini , R. Pillera , G. Volpe

Modeling the timing performance of light-based radiation detectors accurately is essential for optimizing time-of-flight positron emission tomography (TOF-PET). We present an analytic framework that combines existing models to predict the…

Instrumentation and Detectors · Physics 2025-10-08 Nicolaus Kratochwil , Emilie Roncali , Gerard Arino-Estrada

The performance of a prototype Ring Imaging Cherenkov Detector is studied using a charged particle beam. The detector performance, using CF4 and air as radiators, is described. Cherenkov angle precision and photoelectron yield using hybrid…

Silicon photomultipliers are very versatile photo detectors due to their high photon detection efficiency, fast response, single photon counting capability, high amplification, and their insensitivity to magnetic fields. At our institute we…

Nuclear Experiment · Physics 2015-05-18 G. S. M. Ahmed , P. Bühler , J. Marton , K. Suzuki

Currently the standard light sensors for imaging atmospheric Cherenkov telescopes are the classical photo multiplier tubes that are using bialkali photo cathodes. About eight years ago we initiated an improvement program with the Photo…

‹ Prev 1 2 3 10 Next ›