English
Related papers

Related papers: An Open Source Validation System for Continuous Ar…

200 papers

Blood pressure (BP) monitoring is vital in daily healthcare, especially for cardiovascular diseases. However, BP values are mainly acquired through the contact sensing method, which is inconvenient and unfriendly to continuous BP…

Image and Video Processing · Electrical Eng. & Systems 2022-06-24 Jialiang Zhuang , Bin Li , Yun Zhang , Yuheng Chen , Xiujuan Zheng

Oscillometric monitors are the most common automated blood pressure (BP) measurement devices used in non-specialist settings. However, their accuracy and reliability vary under different settings and for different age groups and health…

Signal Processing · Electrical Eng. & Systems 2023-01-25 Niloufar Delfan , Mohamad Forouzanfar

Computational fluid dynamics (CFD) based simulation of coronary blood flow provides valuable hemodynamic markers, such as pressure gradients, for diagnosing coronary artery disease (CAD). However, CFD is computationally expensive,…

Computer Vision and Pattern Recognition · Computer Science 2025-12-12 Rene Lisasi , Michele Esposito , Chen Zhao

Cardiovascular disease (CVD) is a leading cause of morbidity and mortality worldwide, and sustained hypertension is an often silent risk factor, making cuffless continuous blood pressure (BP) monitoring with wearable devices important for…

Signal Processing · Electrical Eng. & Systems 2025-12-02 Yiqiao Chen , Fazheng Xu , Zijian Huang , Juchi He , Zhenghui Feng

Bladder pressure monitoring systems are increasingly vital in diagnosing and managing urinary tract dysfunction. Existing solutions rely heavily on hand-crafted features and shallow classifiers, limiting their adaptability to complex signal…

Signal Processing · Electrical Eng. & Systems 2025-09-30 Chengwei Zhou , Steve Majerus , Gourav Datta

In the case of breast cancer, as with most cancers, early detection can significantly improve a person's chances of survival. This makes it important for there to be an effective and accessible means of regularly checking for manifestations…

Image and Video Processing · Electrical Eng. & Systems 2019-08-28 John Anthony C. Jose , Phoebe Mae L. Ching , Melvin K. Cabatuan

The paper proposes accurate Blood Pressure Monitoring (BPM) based on a single-site Photoplethysmographic (PPG) sensor and provides an energy-efficient solution on edge cuffless wearable devices. Continuous PPG signal preprocessed and used…

Signal Processing · Electrical Eng. & Systems 2021-08-03 Wenrui Lin , Berken Utku Demirel , Mohammad Abdullah Al Faruque , G. P. Li

CoronaryHemodynamics is a comprehensive simulation package developed on the OpenFOAM platform, designed specifically for coronary artery hemodynamics analysis. The package integrates a complete suite of tools for simulation preparation,…

Fluid Dynamics · Physics 2025-01-16 Yijin Mao , Yuwen Zhang

With the development of additive manufacturing, 3D printing technology has become more common nowadays. We designed and 3D printed a cost-effective liquid fluid pressure measurement device that can convert liquid pressure to air pressure.…

Medical Physics · Physics 2019-10-25 Yuqi Jin , Akansha Rao , William Brinkman , Tae-Youl Choi

Pulse wave analysis is an important method used to gather information about the cardiovascular system. Instead of detecting the pulse wave via pressure sensors, bioimpedance measurements can be performed to acquire minuscule changes in the…

Medical Physics · Physics 2019-02-26 Roman Kusche , Paula Klimach , Martin Ryschka

Cardiopulmonary resuscitation (CPR) is one of the essential tools to ensure oxygen supply during cardiac arrest. However, the precise effects of chest compression are not quantifiable to this day. This often results in a low quality of…

Palpation of human tissue during Minimally Invasive Surgery is hampered due to restricted access. In this extended abstract, we present a variable stiffness and dynamic force range sensor that has the potential to address this challenge.…

Medical Physics · Physics 2024-12-16 Abu Bakar Dawood , Zhenyu Zhang , Martin Angelmahr , Alberto Arezzo , Kaspar Althoefer

Magnetic resonance imaging (MRI) can estimate three-dimensional (3D) time-resolved relative pressure fields using 4D-flow MRI, thereby providing rich pressure field information. Clinical alternatives include catheterization and Doppler…

Accurate pressure measurements in micrometric channels are essential for a wide range of microfluidic applications. Existing approaches rely on a variety of sensing mechanisms, but generally require the integration of additional probes or…

Pulse wave measurements provide vital information in medical diagnosis. For this reason, a measurement system is developed for determining the transient time of the pulse wave between the heart and the ear. To detect pressure variations in…

Medical Physics · Physics 2020-08-06 Roman Kusche , Paula Klimach , Ankit Malhotra , Steffen Kaufmann , Martin Ryschka

Today's diagnostics include devices such as pulse oximeters, blood pressure monitors, and temperature measurements. These devices provide vital information to medical personnel when making treatment decisions. Drawing inspiration from the…

Image and Video Processing · Electrical Eng. & Systems 2022-08-26 Akhil Kallepalli , David B James , Mark A Richardson

Continuum robots are advancing bronchoscopy procedures by accessing complex lung airways and enabling targeted interventions. However, their development is limited by the lack of realistic training and test environments: Real data is…

We develop and evaluate two novel purpose-built deep learning (DL) models for synthesis of the arterial blood pressure (ABP) waveform in a cuff-less manner, using a single-site photoplethysmography (PPG) signal. We train and evaluate our DL…

Signal Processing · Electrical Eng. & Systems 2024-06-11 Muhammad Wasim Nawaz , Muhammad Ahmad Tahir , Ahsan Mehmood , Muhammad Mahboob Ur Rahman , Kashif Riaz , Qammer H. Abbasi

BPClip is an ultra-low-cost cuffless blood pressure monitor. As a universal smartphone attachment, BPClip leverages the computational imaging power of smartphones to perform oscillometry based blood pressure measurements. This paper…

Signal Processing · Electrical Eng. & Systems 2023-08-14 Yinan Xuan , Ava J. Fascetti , Colin Barry , Edward J. Wang

Fluid flow simulation is a highly active area with applications in a wide range of engineering problems and interactive systems. Meshless methods like the Moving Particle Semi-implicit (MPS) are a great alternative to deal efficiently with…