English
Related papers

Related papers: Characterization of Multiple Channels Room Tempera…

200 papers

Recent advances in the development of cryogenic particle detectors such as magnetic microcalorimeters (MMCs) allow the fabrication of sensor arrays with an increasing number of pixels. Since these detectors must be operated at the lowest…

Instrumentation and Detectors · Physics 2025-10-22 T. Muscheid , R. Gartmann , N. Karcher , F. Schuderer , M. Neidig , L. E. Ardila-Perez , M. Balzer , S. Kempf , O. Sander

We present a method for precise monitoring of the loop gain of transition edge sensors (TES) under electrothermal feedback. The measurement is implemented on the ICE DfMux electronics and operates simultaneously with Digital Active Nulling…

Instrumentation and Methods for Astrophysics · Physics 2024-07-08 T. de Haan , T. Adkins , M. Hazumi , D. Kaneko , J. Montgomery , G. Smecher , A. Suzuki , Y. Zhou

The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final…

With applications in cosmology, infrared astronomy and CMB survey, frequency-division multiplexing (FDM) proved to be a viable readout for transition-edge sensors (TES). We investigate the occurrence of out-of-band resonances (OBR) which…

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS…

Instrumentation and Detectors · Physics 2021-09-03 H. Sun , D. Gong , W. Zhang , C. Edwards , c G. Huang , X. Huang , C. Liu , T. Liu , T. Liu , J. Olsen , Q. Sun , J. Wu , J. Ye , L. Zhang

We report on the design, commissioning, and initial measurements of a Transition-edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at the National Institute of Standards and Technology (NIST). Over the past few…

We present a readout chip prototype for future pixel detectors with timing capabilities. The prototype is intended for characterizing 4D pixel arrays with a pixel size of $100\times100~\mu \text{m}^2$, where the sensors are Low Gain…

Instrumentation and Detectors · Physics 2023-02-15 Matias Senger , Lea Caminada , Benjamin Kilminster , Anna Macchiolo , Beat Meier , Stephan Wiederkehr

A new readout technique was developed with the primary aim of keeping the number of channels in the front-end electronics as low as possible when scaling up the sensitive area of a Resistive Plate Chamber (RPC). The readout method here…

Instrumentation and Detectors · Physics 2024-07-16 João Pedro de Carvalho Saraiva , Alberto Blanco Castro

Large arrays of cryogenic detectors, including transition-edge sensors (TESs) or magnetic micro-calorimeters (MMCs), are needed for future experiments across a wide range of applications. Complexities in integration and cryogenic wiring…

Instrumentation and Detectors · Physics 2020-01-10 C. Yu , A. Ames , S. Chaudhuri , C. Dawson , K. D. Irwin , S. E. Kuenstner , D. Li , C. J. Titus

The Short Baseline Near Detector (SBND) is one of three liquid argon (LAr) neutrino detectors sitting in the Booster Neutrino Beam (BNB) at Fermilab as part of the Short Baseline Neutrino (SBN) program. The detector is in a cryostat holding…

Instrumentation and Detectors · Physics 2019-10-16 Shanshan Gao

A well-balanced detector with high sensitivity and low noise is presented in this paper. The two-stage amplification structure is used to increase electronic gain while keeping an effective bandwidth of about 70 MHz. In order to further…

Instrumentation and Detectors · Physics 2018-06-13 Qi-Ming Lu , Qi Shen , Yuan Cao , Sheng-Kai Liao , Cheng-Zhi Peng

We describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a Transition Edge Sensor based two-channel silicon athermal phonon detector with 375…

A large Time Projection Chamber (TPC) is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019-2020, the LHC will deliver Pb beams colliding at an…

Instrumentation and Detectors · Physics 2019-10-09 Piotr Gasik

We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition-edge-sensor…

In this paper we present a new measurement setup, where a transitionedge sensor detector array is used to detect X-rays in particle induced X-ray emission measurements with a 2 MeV proton beam. Transition-edge sensors offer orders of…

Quantitative electron magnetic circular dichroism (EMCD) in transmission electron microscopy (TEM) enables the measurement of magnetic moments with elemental and atomic site sensitivity, but its practical application is fundamentally…

Materials Science · Physics 2025-10-29 Hitoshi Makino , Bernd Rellinghaus , Sebastian Schneider , Axel Lubk , Darius Pohl

We present results on phonon quasidiffusion and Transition Edge Sensor (TES) studies in a large, 3 inch diameter, 1 inch thick [100] high purity germanium crystal, cooled to 50 mK in the vacuum of a dilution refrigerator, and exposed with…

Quantum computing technology is maturing at a relentless pace, yet individual quantum bits are wired one by one. As quantum processors become more complex, they require efficient interfaces to deliver signals for control and readout while…

Mesoscale and Nanoscale Physics · Physics 2019-06-18 S. Schaal , A. Rossi , S. Barraud , J. J. L. Morton , M. F. Gonzalez-Zalba

A high accuracy and high sensitivity system architecture is proposed for the read-out circuit of electrical impedance tomography system-on-chip. The switched ratiometric technique is applied in the proposed architecture. The proposed system…

Medical Physics · Physics 2018-10-24 Hui Li , Boxiao Liu , Yongfu Li , Guoxing Wang , Yong Lian

Microcalorimeter instruments aboard future X-ray observatories will require an anti-coincidence (anti-co) detector to veto charged particle events and reduce the non-X-ray background. We have developed a large-format, TES-based prototype…