English
Related papers

Related papers: High count rate effects in event processing for XR…

200 papers

The spectroscopic performance of x-ray instruments can be affected at high count rates. The effects and mitigation in the optical chain, such as x-ray attenuation filters or de-focusing mirrors, are widely discussed, but those in the signal…

The Resolve instrument on the X-ray Imaging and Spectroscopy Mission (XRISM) uses a 36-pixel microcalorimeter designed to deliver high-resolution, non-dispersive X-ray spectroscopy. Although it is optimized for extended sources with low…

The analysis of data from x-ray microcalorimeters requires great care; their excellent intrinsic energy resolution cannot usually be achieved in practice without a statistically near-optimal pulse analysis and corrections for important…

Instrumentation and Detectors · Physics 2017-02-03 J. W. Fowler , B. K. Alpert , W. B. Doriese , Y. -I. Joe , G. C. O'Neil , J. N. Ullom , D. S. Swetz

Electromagnetic interference (EMI) for low-temperature detectors is a serious concern in many missions. We investigate the EMI caused by the spacecraft components to the x-ray microcalorimeter of the Resolve instrument onboard the X-Ray…

Resolve is a payload hosting an X-ray microcalorimeter detector operated at 50 mK in the X-Ray Imaging and Spectroscopy Mission (XRISM). It is currently under development as part of an international collaboration and is planned to be…

The effective bandwidth of an energy dispersive x-ray fluorescence spectroscopy system is limited by the timing of incident photons. When multiple photons strike the detector within the processing time of the detector photon pile-up occurs…

Instrumentation and Detectors · Physics 2016-12-02 Benjamin A Lucas

The XRISM (X-Ray Imaging and Spectroscopy Mission) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an x-ray microcalorimeter detector, which was…

The Resolve soft X-ray spectrometer is the high spectral resolution microcalorimeter spectrometer for the XRISM mission. In the beam of Resolve there is a filter wheel containing \xray{} filters. In the beam also is an active calibration…

Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each…

Instrumentation and Methods for Astrophysics · Physics 2017-02-03 J. W. Fowler , B. K. Alpert , W. B. Doriese , D. A. Fischer , C. Jaye , Y. I. Joe , G. C. O'Neil , D. S. Swetz , J. N. Ullom

When processing large amounts of data, the rate at which reading and writing can take place is a critical factor. High energy physics data processing relying on ROOT is no exception. The recent parallelisation of LHC experiments' software…

Distributed, Parallel, and Cluster Computing · Computer Science 2018-04-11 Guilherme Amadio , Brian Bockelman , Philippe Canal , Danilo Piparo , Enric Tejedor , Zhe Zhang

Low-temperature detectors often use mechanical coolers as part of the cooling chain in order to reach sub-Kelvin operating temperatures. The microphonics noise caused by the mechanical coolers is a general and inherent issue for these…

Instrumentation and Methods for Astrophysics · Physics 2023-03-03 R. Imamura , H. Awaki , M. Tsujimoto , S. Yamada , F. S. Porter , C. A. Kilbourne , R. L. Kelley , Y. Takei

Accurate X-ray spectroscopic measurements are fundamental for deriving basic physical parameters of the most abundant baryon components in the Universe. The plethora of X-ray observatories currently operational enables a panchromatic view…

High Energy Astrophysical Phenomena · Physics 2025-10-15 XRISM collaboration

We present the results of a study on the impact of particles of galactic (GCR) and solar origin for the X-ray Microcalorimeter Spectrometer (XMS) aboard an astronomical satellite flying in an orbit at the second Lagrangian point (L2). The…

Instrumentation and Methods for Astrophysics · Physics 2012-07-10 S. Lotti , E. Perinati , L. Natalucci , L. Piro , T. Mineo , L. Colasanti , C. Macculi

To take advantage of high-resolution optics sensitive to a broad energy range, future X-ray imaging instruments will require thick detectors with small pixels. This pixel aspect ratio affects spectral response in the soft X-ray band, vital…

Exotic atom experiments place transition-edge-sensor (TES) microcalorimeter arrays in a high-energy charged particle rich environment. When a high-energy charged particle passes through the silicon substrate of a TES array, a large amount…

A formalism for treating the pile-up produced in solid-state detectors by laser-driven pulsed x-ray sources has been developed. It allows the direct use of x-ray spectroscopy without artificially decreasing the number of counts in the…

Instrumentation and Detectors · Physics 2018-06-01 Guillermo Hernández , Francisco Fernández

Using simultaneous observations in X-rays and optical, we have performed a homogeneous analysis of the cross-correlation behaviours of four X-ray binaries: SWIFT J1753.5-0127, GX 339-4, Sco X-1, and Cyg X-2. With high time-resolution…

The CG-2 beamline at the High Flux Isotope Reactor (HFIR) exhibits a notable discrepancy between observed count rates and the count rates we would expect based on a Monte-Carlo neutron ray-trace simulation. These simulations consistently…

Instrumentation and Detectors · Physics 2024-04-16 James M. Rogers , Matthew J. Frost , Lisa DeBeer-Schmitt

Certain radiation detectors are 'paralyzed' with high input count rates. When applied to count rates close to the event discriminator working rate the one-parameter dead time model fails. Here we present a corrected paralyzable detector…

Instrumentation and Detectors · Physics 2026-03-27 Yueyun Chen , Matthew Mecklenburg
‹ Prev 1 2 3 10 Next ›