Related papers: Statistical Reconstruction For Anisotropic X-ray D…
Anisotropic X-ray Dark-field Tomography (AXDT) is a recently developed imaging modality that enables the visualization of oriented microstructures using lab-based X-ray grating interferometer setups. While there are very promising…
Due to the merit of establishing volumetric data, X-ray computed tomography (XCT) is increasingly used as a non-destructive evaluation technique in the quality control of advanced manufactured parts with complex non-line-of-sight features.…
X-ray diffraction tomography (XDT) resolves spatially-variant XRD profiles within macroscopic objects, and provides improved material contrast compared to the conventional transmission-based computed tomography (CT). However, due to the…
We demonstrate dark-field x-ray microtomography in a compact, laboratory-based system capable of resolving attenuation, phase, and anisotropic scattering signals with micrometer-scale resolution across centimetre-scale samples. The method…
Materials' microstructure strongly influences its performance and is thus a critical aspect in design of functional materials. Previous efforts on microstructure mediated design mostly assume isotropy, which is not ideal when material…
We introduce a structured illumination technique for dark-field x-ray microscopy optimized for three-dimensional imaging of ordered materials at sub-micrometer length scales. Our method utilizes a coded aperture to spatially modulate the…
In this paper, we present XctDiff, an algorithm framework for reconstructing CT from a single radiograph, which decomposes the reconstruction process into two easily controllable tasks: feature extraction and CT reconstruction.…
Density reconstruction from X-ray projections is an important problem in radiography with key applications in scientific and industrial X-ray computed tomography (CT). Often, such projections are corrupted by unknown sources of noise and…
Non-destructive cross-sectional characterization of materials systems with a resolution in the nanometer range and the ability to allow for time-resolved in-situ studies is of great importance in material science. Here, we present such a…
Optical tomographic reconstruction of a 3D nanoscale specimen is hindered by the axial diffraction limit, which is 2-3 times worse than the focal plane resolution. We propose and experimentally demonstrate an axial super-resolution…
Biaxial anisotropy, arising from distinct optical responses along three principal directions, underlies the complex structure of many crystalline, polymeric, and biological materials. However, existing techniques such as X-ray diffraction…
In ultrasound nondestructive testing, a widespread approach is to take synthetic aperture measurements from the surface of a specimen to detect and locate defects within it. Based on these measurements, imaging is usually performed using…
This paper introduces an extended tensor decomposition (XTD) method for model reduction. The proposed method is based on a sparse non-separated enrichment to the conventional tensor decomposition, which is expected to improve the…
X-ray computed tomography (XCT) is an important tool for high-resolution non-destructive characterization of additively-manufactured metal components. XCT reconstructions of metal components may have beam hardening artifacts such as cupping…
Properties in crystalline and ordered materials tend to be anisotropic, with their orientation affecting the macroscopic behavior and functionality of materials. The ability to image the orientation of anisotropic material properties in…
Dark-field images are formed by small-angle scattering of x-ray photons. The small-angle scattering signal is particularly sensitive to structural variations and density fluctuation on a length scale of several ten to hundred nanometers,…
Advances in multi-spectral detectors are causing a paradigm shift in X-ray Computed Tomography (CT). Spectral information acquired from these detectors can be used to extract volumetric material composition maps of the object of interest.…
Fluorescence microscopy images usually show severe anisotropy in axial versus lateral resolution. This hampers downstream processing, i.e. the automatic extraction of quantitative biological data. While deconvolution methods and other…
X-ray tomography is a reliable tool for determining the inner structure of 3D object with penetrating X-rays. However, traditional reconstruction methods such as FDK require dense angular sampling in the data acquisition phase leading to…
X-ray computed tomography (XCT) is a key tool in non-destructive evaluation of additively manufactured (AM) parts, allowing for internal inspection and defect detection. Despite its widespread use, obtaining high-resolution CT scans can be…