Related papers: Calorimetric Wire Detector for Measurement of Atom…
This paper deals with an analytical modeling of heat transfers simulating a new radiation calorimeter operating in a temperature range from -50 {\deg}C to 150 {\deg}C. The aim of this modeling is the evaluation of the feasibility and…
The CREAM calorimeter, designed to measure the spectra of cosmic-ray nuclei from under 1 TeV to 1000 TeV, is a 20 radiation length (X0) deep sampling calorimeter. The calorimeter is comprised of 20 layers of tungsten interleaved with 20…
A method of using vacuum calorimetry as a means of determining directly the energy deposited in an electrically exploded wire is presented. This energy determination is compared with that given by the time integral of the product of voltage…
A new approach to the technique of scanning by wires is developed. Novelty of the method is that the wire heating quantity is used as a source of information about the number of interacting particles. To increase the accuracy and…
In nuclear, particle and astroparticle physics experiments, calorimeters are used to measure the properties of particles with kinetic energies that range from a fraction of 1 eV to 10^20 eV or more. These properties are not necessarily…
In order to investigate the anomalous heat effect (AHE) in NiCu multilayer thin film, photon radiation calorimetry has been developed. Three types of photon detectors are employed to cover a wide range of wavelengths from 0.3 um to 5.5 um,…
In many situations, the dual-purpose heater/thermometer wires used in the three-omega method, one of the most precise and sensitive techniques for measuring the thermal conductivity of thin films and interfaces, must include bends and…
A silicon-tungsten (Si-W) sampling calorimeter, consisting of 19 alternate layers of silicon pad detectors (individual pad area of 1~cm$^2$) and tungsten absorbers (each of one radiation length), has been constructed for measurement of…
Chromatic calorimetry introduces a novel approach to calorimeter design in High Energy Physics (HEP) by integrating Quantum Dot (QD) technology into traditional homogeneous calorimeters. The tunable emission spectra of QDs provide new…
A novel calorimeter sensor for electron, photon and hadron energy measurement based on Secondary Emission(SE) to measure ionization is described, using sheet-dynodes directly as the active detection medium; the shower particles in an SE…
In particle physics, homogeneous calorimeters are used to measure the energy of particles as they interact with the detector material. Although not as precise as trackers or muon detectors, these calorimeters provide valuable insights into…
The measurement of cosmic rays at energies exceeding 100 TeV per nucleon is crucial for enhancing the understanding of high-energy particle propagation and acceleration models in the Galaxy. HERD is a space-borne calorimetric experiment…
Every time a chemical reaction occurs, an energy exchange between reactants and environment exists, which is defined as the enthalpy of the reaction. In the last decades, research has resulted in an increasing number of devices at the…
Molecular beam experiments that use low-temperature bolometers as (energy-) detectors are well suited to the study of physisorption and recombination of hydrogen on low-temperature surfaces. Experiments where this technique is combined with…
A calorimeter was built to measure the heat from a porous capacitive working electrode connected in a three-electrode configuration. This makes it possible to detect differences between cathodic and anodic heat production. The…
We report on the simulation results for the angular resolution of an electromagnetic (EM) sampling calorimeter with photons in the range of 100~MeV to 2~GeV. The simulation model of the EM calorimeter consists of alternating layers of a…
An imaging calorimeter has been designed and is being built for the PAMELA satellite-borne experiment. The physics goals of the experiment are the measurement of the flux of antiprotons, positrons and light isotopes in the cosmic radiation.…
The complex ac impedance of a bolometer or microcalorimeter detector is easily measured and can be used to determine thermal time constants, thermal resistances, heat capacities, and sensitivities. Accurately extracting this information…
A theoretical proposal that Coulomb-coupled quantum dots can be used as quantum probes to determine the temperature of a sample (i.e., an electronic reservoir) is proposed. Through the regulation of the positive or negative voltage bias in…
This study introduces chromatic calorimetry, a novel particle detection method that uses strategically layered scintillators with different emission wavelengths. This approach aims to enhance energy measurement by capturing particle…