Related papers: Quantum phase estimation and realistic detection s…
In this paper, we derive a general expression of the quantum Fisher information of an SU(1,1) interferometer with an arbitrary state and a Fock state as inputs by the phase-averaging method. Our results show that the same quantum Fisher…
The quantum Cram\'er-Rao bound sets a fundamental limit on the accuracy of unbiased parameter estimation in quantum systems, relating the uncertainty in determining a parameter to the inverse of the quantum Fisher information. We…
We study the multiparameter sensitivity bounds of a sensor made by an array of $d$ spatially-distributed Mach-Zehnder interferometers (MZIs). A generic single non-classical state is mixed with $d-1$ vacuums to create a $d$-modes entangled…
Mach-Zehnder interferometer is a common device in quantum phase estimation and the photon losses in it are an important issue for achieving a high phase accuracy. Here we thoroughly discuss the precision limit of the phase in the…
The attainability of the quantum Cram\'er-Rao bound [QCR], the ultimate limit in the precision of the estimation of a physical parameter, requires the saturation of the quantum information bound [QIB]. This occurs when the Fisher…
The quantum Fisher information matrix (QFIM) is central to multiparameter quantum metrology, dictating the attainable sensitivity via the quantum Cram\'er-Rao bound. In this work, we investigate the ultimate precision limits for…
The quantum Fisher information (QFI) in SU(2) and SU(1,1) interferometers was considered, and the QFI-only calculation was overestimated. In general, the phase estimation as a two-parameter estimation problem, and the quantum Fisher…
We consider an optical interferometer with coherent light in one input and a squeezed vacuum in another. Such an interferometer is known to beat the standard quantum limit of sensitivity to the difference of phase shifts in its arms. We…
By using the quantum Fisher information (QFI), we address the process of \textit{single}-parameter estimation in the presence of bosonic as well as fermionic environments and protection of information against the noise. In particular, the…
It is shown that the condition for achieving the quantum Cramer-Rao bound of phase estimation in conventional two-path interferometers is that the state is symmetric with regard to an (unphysical) exchange of the two paths. Since path…
Here we are investigating the enhancement in phase sensitivity and resolution in Mach-Zehnder interferometer (MZI) based quantum LiDAR. We are using multi-photonic state (MPS), superposition of four coherent states [1], as the input state…
Seeking the available precision limit of unknown parameters is a significant task in quantum parameter estimation. One often resorts to the widely utilized quantum Cramer-Rao bound (QCRB) based on unbiased estimators to finish this task.…
Since the initial discovery of the Wootters-Zurek no-cloning theorem, a wide variety of quantum cloning machines have been proposed aiming at imperfect but optimal cloning of quantum states within its own context. Remarkably, most previous…
Quantum effects like entanglement and coherent amplification can be used to drastically enhance the accuracy of quantum parameter estimation beyond classical limits. However, challenges such as decoherence and time-dependent errors hinder…
We present measurement schemes that do not rely on photon-number resolving detectors, but that are nevertheless optimal for estimating a differential phase shift in interferometry with either an entangled coherent state or a…
In this work, we discuss two phase-measurement methods for the Mach-Zehnder interferometer (MZI) in the presence of internal losses and give the corresponding optimum conditions. We find theoretically that when the core parameters…
It is shown that the maximal phase sensitivity of a two-path interferometer with high-intensity coherent light and squeezed vacuum in the input ports can be achieved by photon-number-resolving detection of only a small number of photons in…
Estimating multiple parameters simultaneously is of great importance to measurement science and application. For a single parameter, atomic Ramsey interferometry (or equivalently optical Mach-Zehnder interferometry) is capable of providing…
The double-slit interferometer and the Mach-Zehnder interferometer (MZI) with balanced beam splitters are prototypical setups for investigating the quantum wave-particle duality. These setups induced a quantitative association of…
Homodyne detection is often used for interferometers based on nonlinear optical gain media. For the configuration of a seeded, 'truncated SU(1,1)' interferometer Anderson et al. (Phys. Rev. A 95, 063843 (2017)) showed how to optimize the…