English
Related papers

Related papers: Performance Optimizations and Evaluations for the …

200 papers

Various applications of quantum devices call for an accurate calibration of cryogenic amplification chains. To this end, we present a convenient calibration scheme and use it to accurately measure the total gain and noise temperature of an…

Continuous-time measurements are instrumental for a multitude of tasks in quantum engineering and quantum control, including the estimation of dynamical parameters of open quantum systems monitored through the environment. However, such…

Quantum Physics · Physics 2023-04-12 Alfred Godley , Madalin Guta

The Multiple Amplifier Sensing Charge-Coupled Device (MAS-CCD) has emerged as a promising technology for astronomical observation, quantum imaging, and low-energy particle detection due to its ability to reduce the readout noise without…

An ionization chamber with gaseous samples has been designed. It has been tested on the beam of the pulsed reactor IBR-30 of FLNP, JINR-Dubna. The experiment has been carried out with resonance neutrons. The exposed gas volume serves as a…

Nuclear Experiment · Physics 2007-05-23 R. Machrafi , G. Kim , D. Son , Yu. M. Gledenov , V. I. Salatski , P. V. Sedyshev , J. Andrzejewski , P. Szalanski

The ICARUS liquid argon time projection chamber (LArTPC) neutrino detector has been taking physics data since 2022 as part of the Short-Baseline Neutrino (SBN) Program. This paper details the equalization of the response to charge in the…

High Energy Physics - Experiment · Physics 2024-08-06 ICARUS collaboration , P. Abratenko , N. Abrego-Martinez , A. Aduszkiewic , F. Akbar , L. Aliaga Soplin , M. Artero Pons , J. Asaadi , W. F. Badgett , B. Baibussinov , B. Behera , V. Bellini , R. Benocci , J. Berger , S. Berkman , S. Bertolucci , M. Betancourt , M. Bonesini , T. Boone , B. Bottino , A. Braggiotti , D. Brailsford , S. J. Brice , V. Brio , C. Brizzolari , H. S. Budd , A. Campani , A. Campos , D. Carber , M. Carneiro , I. Caro Terrazas , H. Carranza , F. Castillo Fernandez , A. Castro , S. Centro , G. Cerati , A. Chatterjee , D. Cherdack , S. Cherubini , N. Chitirasreemadam , M. Cicerchia , T. E. Coan , A. Cocco , M. R. Convery , L. Cooper-Troendle , S. Copello , A. A. Dange , A. de Roeck , S. Di Domizio , L. Di Noto , C. Di Stefano , D. Di Ferdinando , M. Diwan , S. Dolan , L. Domine , S. Donati , F. Drielsma , J. Dyer , S. Dytman , A. Falcone , C. Farnese , A. Fava , A. Ferrari , N. Gallice , F. G. Garcia , C. Gatto , D. Gibin , A. Gioiosa , W. Gu , A. Guglielmi , G. Gurung , H. Hausner , A. Heggestuen , B. Howard , R. Howell , I. Ingratta , C. James , W. Jang , Y. -J. Jwa , L. Kashur , W. Ketchum , J. S. Kim , D. -H. Koh , J. Larkin , Y. Li , C. Mariani , C. M. Marshall , S. Martynenko , N. Mauri , K. S. McFarland , D. P. Méndez , A. Menegolli , G. Meng , O. G. Miranda , A. Mogan , N. Moggi , E. Montagna , C. Montanari , A. Montanari , M. Mooney , G. Moreno-Granados , J. Mueller , M. Murphy , D. Naples , V. C. L. Nguyen , S. Palestini , M. Pallavicini , V. Paolone , R. Papaleo , L. Pasqualini , L. Patrizii , L. Paudel , G. Petrillo , C. Petta , V. Pia , F. Pietropaolo , F. Poppi , M. Pozzato , G. Putnam , X. Qian , A. Rappoldi , G. L. Raselli , S. Repetto , F. Resnati , A. M. Ricci , G. Riccobene , E. Richards , M. Rosenberg , M. Rossella , P. Roy , C. Rubbia , M. Saad , S. Saha , P. Sala , S. Samanta , P. Sapienza , A. Scaramelli , A. Scarpelli , D. Schmitz , A. Schukraft , D. Senadheera , S-H. Seo , F. Sergiampietri , G. Sirri , J. S. Smedley , J. Smith , L. Stanco , J. Stewart , H. A. Tanaka , F. Tapia , M. Tenti , K. Terao , F. Terranova , V. Togo , D. Torretta , M. Torti , F. Tortorici , R. Triozzi , Y. -T. Tsai , S. Tufanli , T. Usher , F. Varanini , S. Ventura , M. Vicenzi , C. Vignoli , B. Viren , Z. Williams , R. J. Wilson , P. Wilson , J. Wolfs , T. Wongjirad , A. Wood , E. Worcester , M. Wospakrik , H. Yu , J. Yu , A. Zani , J. Zennamo , J. Zettlemoyer , C. Zhang , S. Zucchelli

Applications of inertial measurement units are extremely diverse, and are expected to see a further increase in number due to current trends in robotics as well as recent advances in Micro Electromechanical sensors (MEMS). The traditional…

Robotics · Computer Science 2017-08-16 William T. Conlin

We present a compact, ionization-based detector for the state-selective and spatially resolved measurement of individual Rydberg atoms trapped in the vicinity of an atom chip. The system combines an electrostatic lens system for guiding…

Quantum Physics · Physics 2025-07-08 Conny Glaser , Dominik Jakab , Florian Jessen , Manuel Kaiser , Jozsef Fortagh , Andreas Günther

Inertial measurement units (IMUs) are used in medical applications for many different purposes. However, an IMU's measurement accuracy can degrade over time, entailing re-calibration. In their 2014 paper, Tedaldi et al. presented an IMU…

Signal Processing · Electrical Eng. & Systems 2022-07-12 Fritz Webering , Sarah Kleinjohann , Nils Stanislawski , Holger Blume

The formation of a submicron optical cavity on one side of a metal-insulator-metal (MIM) tunneling device induces a measurable electrical current between the two metal layers with no applied voltage. Reducing the cavity thickness increases…

Mesoscale and Nanoscale Physics · Physics 2021-04-06 Garret Moddel , Ayendra Weerakkody , David Doroski , Dylan Bartusiak

The design, construction, and characterization of the Multi-Sampling Ionization Chamber, MuSIC@Indiana, are described. This detector provides efficient and accurate measurement of the fusion cross-section at near-barrier energies. The…

An inertial sensor design is proposed in this paper to achieve high sensitivity and large dynamic range in the sub-Hz frequency regime. High acceleration sensitivity is obtained by combining optical cavity readout systems with…

Quantum Physics · Physics 2022-09-23 Yanqi Zhang , Adam Hines , Dalziel Wilson , Felipe Guzman

Deformation analyses of tailings dams under dynamic conditions require using earthquake records as input loading. Moreover, these records must represent the local seismicity, expressed by ground motion power indicators denominated intensity…

Geophysics · Physics 2022-11-21 Nicolas A. Labanda , Roberto J. Cier , Mauro G. Sottile

We have constructed and tested a 2d position sensitive parallel-plate gas ionization chamber with scanned charge transfer readout. The scan readout method described here is based on the development of a new position dependent charge…

Instrumentation and Detectors · Physics 2009-11-10 F. Gomez , A. Iglesias , R. Lobato , J. Mosquera , J. Pardo , J. Pena , A. Pazos , M. Pombar , A. Rodriguez

The design, construction and performance characteristics of a simple axial-field ionization chamber suitable for identifying ions in a radioactive beam are presented. Optimized for use with low-energy radioactive beams (< 5 MeV/A) the…

Instrumentation and Detectors · Physics 2016-10-12 J. Vadas , Varinderjit Singh , G. Visser , A. Alexander , S. Hudan , J. Huston , B. B. Wiggins , A. Chbihi , M. Famiano , M. M. Bischak , R. T. deSouza

The use of an interferometer to perform an ultra-precise parameter estimation under noisy conditions is a challenging task. Here we discuss nearly optimal measurement schemes for a well known,sensitive input state, squeezed vacuum and…

The kinetic analyses are quite important when it comes to understand the particle behavior in any device as they start to deviate from continuum nature. In the present study, kinetic simulations are performed using Particle-in-Cell (PIC)…

Plasma Physics · Physics 2020-12-15 D. Bhattacharjee , S. Adhikari , N. Buzarbaruah , S. R. Mohanty

Nanopores that exhibit ionic current rectification (ICR) behave like diodes, such that they transport ions more efficiently in one direction than the other. Conical nanopores have been shown to rectify ionic current, but only those with at…

Chemical Physics · Physics 2022-06-08 Long Ma , Zhongwu Li , Zhishan Yuan , Chuanzhen Huang , Zuzanna S. Siwy , Yinghua Qiu

We demonstrate how the presence of gain-loss contrast between two coupled identical resonators can be used as a new degree of freedom to enhance the modulation frequency response of laser diodes. An electrically pumped microring laser…

The idea of a hermetic quartz chamber in a dual-phase xenon time projection chamber (TPC) has the potential to improve the detector sensitivity for direct dark matter searches in the future. A major challenge facing TPC detectors in future…

During the scheduled high luminosity upgrade of LHC, the world's largest particle physics accelerator at CERN, the position sensitive silicon detectors installed in the vertex and tracking part of the CMS experiment will face more intense…

Instrumentation and Detectors · Physics 2015-01-21 T. Peltola
‹ Prev 1 4 5 6 7 8 10 Next ›