English
Related papers

Related papers: Alleviating the trade-off between coincidence time…

200 papers

In this paper we prove that the choice of a suitable treatment of the scintillator surfaces, along with suitable photodetectors electronics and specific algorithms for raw data analysis, allow to achieve an optimal tradeoff between energy,…

Medical Physics · Physics 2012-03-02 Luigi Cosentino , Paolo Finocchiaro , Alfio Pappalardo , Franco Garibaldi

We are exploring a scintillator-based detector with potential of high sensitivity, DOI capability and timing resolution in a single-side readout configuration. Our concept combines: 1) A design with 2+ crystal arrays stacked with relative…

Instrumentation and Detectors · Physics 2021-04-08 L. Bläckberg , S. Sajedi , G. El Fakhri , H. Sabet

The aim of this work is to show the potential capabilities of monolithic crystals coupled to large SiPM arrays, to be considered as detector blocks for PET scanners enabling Time Of Flight (TOF) capabilities. Monolithic blocks allow one to…

Current clinical PET systems utilize detectors where the scintillator typically contains single elements of 3 - 6 mm width and about 20 mm height. While providing good TOF performance, this design limits the spatial resolution and causes…

Instrumentation and Detectors · Physics 2022-11-17 Florian Mueller , Stephan Naunheim , Yannick Kuhl , David Schug , Torsten Solf , Volkmar Schulz

Accurate Time-of-Flight (TOF) measurement with sub-100 picosecond resolution is a critical requirement for particle identification in future high-energy physics experiments, such as the Belle II $K_{L}$ and Muon (KLM) detector upgrade.…

Instrumentation and Detectors · Physics 2026-05-14 Ziyi Yang , Xiyang Wang , Shiming Zou , Ting Wang , Kairui Huang , Wanyi Zhuang , Yicheng Pu , Xiaolong Wang

This work presents the 8-channel FastIC+, a low-power consumption and highly configurable multi-channel front-end ASIC with internal digitization, for the readout of photo-sensors with picosecond time resolution and intrinsic gain. This…

Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing…

Instrumentation and Detectors · Physics 2016-04-19 J. W. Zhao , B. H. Sun , I. Tanihata , S. Terashima , L. H. Zhu , A. Enomoto , D. Nagae , T. Nishimura , S. Omika , A. Ozawa , Y. Takeuchi , T. Yamaguchi

Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a…

In this paper we use detailed Monte Carlo simulations to demonstrate that liquid xenon (LXe) can be used to build a Cherenkov-based TOF-PET, with an intrinsic coincidence resolving time (CRT) in the vicinity of 10 ps. This extraordinary…

Instrumentation and Detectors · Physics 2017-10-11 Juan Jose Gomez-Cadenas , José María Benlloch-Rodríguez , Paola Ferrario

The measurement of the time of flight of the two 511 keV gammas recorded in coincidence in a PET scanner provides an effective way of reducing the random background and therefore increases the scanner sensitivity, provided that the…

Instrumentation and Detectors · Physics 2016-10-12 J. J Gomez-Cadenas , J. M. Benlloch-Rodríguez , P. Ferrario , F. Monrabal , J. Rodríguez , J. F. Toledo

The potential of photon detectors to achieve precise timing information is of increasing importance in many domains, PET and CT scanners in medical imaging and particle physics detectors, amongst others. The goal to increase by an order of…

Instrumentation and Detectors · Physics 2021-01-11 S. Enoch , A. Gola , P. Lecoq , A. Rivetti

The time resolution (TR) is one of the most important characteristic of a detector. For the case of a scintillator, the collection of light also is important, it depends of the effective area of the photo-sensor (\textit{Scorer}). The…

This work explores the combination of liquid xenon as a scintillating medium and silicon photomultipliers as a readout in Positron Emission Tomography (PET) for enhanced Time-Of-Flight resolution. We present the results of our first…

Artificial intelligence (AI) is entering medical imaging, mainly enhancing image reconstruction. Nevertheless, improvements throughout the entire processing, from signal detection to computation, potentially offer significant benefits. This…

Machine Learning · Computer Science 2023-10-27 Stephan Naunheim , Yannick Kuhl , David Schug , Volkmar Schulz , Florian Mueller

In recent years, SiPM photoelectric devices have drawn much attention in the domain of time-of-flight-based positron emission tomography (TOF-PET). Using them to construct PET detectors with excellent coincidence time resolution (CTR) is…

Instrumentation and Detectors · Physics 2018-06-08 Liwei Wang , Yonggang Wang , Qiang Cao , Yong Xiao , Chong Liu

Plastic scintillation detectors for Time-of-Flight (TOF) measurements are almost essential for event-by-event identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of 50 $\times$ 50 $\times$…

The barrel time-of-flight (TOF) detector for the PANDA experiment at FAIR in Darmstadt is planned as a scintillator tile hodoscope (SciTil) using 8000 small scintillator tiles. It will provide fast event timing for a software trigger in the…

Instrumentation and Detectors · Physics 2015-06-18 S. E. Brunner , L. Gruber , J. Marton , H. Orth , K. Suzuki

Balloon- and space-borne cosmic-ray experiments employ plastic scintillators read out by silicon photomultipliers (SiPMs) to achieve picosecond-level time resolutions for triggering and particle identification. The performance of these…

Instrumentation and Detectors · Physics 2025-11-14 José Reyes Castillo , Saúl Aguilar Salazar , Diego Mauricio Gomez Coral

A prototype of DIRC-like Time-of-Flight detector (DTOF), including a pico-second time measurement electronics, is developed and tested preliminarily. The basic structure of DTOF is composed of a fused silica radiator connected to fast…

Instrumentation and Detectors · Physics 2018-06-08 Qiang Cao , Xin Li , Liwei Wang , Jie Kuang , Yonggang Wang , Cheng Li

The accuracy of hadrontherapy treatment is currently limited by ion-range uncertainties. In order to fully exploit the potential of this technique, we propose the development of a novel system for online control of particle therapy, based…

‹ Prev 1 2 3 10 Next ›