English
Related papers

Related papers: Geant4-based technical simulation study of plastic…

200 papers

Positron Annihilation Lifetime Spectroscopy (PALS) is a powerful technique for detecting microstructural defects in various material classes. In a commonly used 180{\deg} detector configuration equipped with plastic scintillators,…

Instrumentation and Detectors · Physics 2025-05-06 Dominik Boras , Danny Petschke , Torsten Staab

Positron Annihilation Lifetime Spectroscopy (PALS) is a non-destructive radiological technique widely used in material science studies. PALS typically relies on an analog coincidence measurement setup and allows the estimate of the positron…

Instrumentation and Detectors · Physics 2019-08-14 Ming Fang , Nathan Bartholomew , Angela Di Fulvio

Plastic scintillators are widely used as particle detectors in many fields, mainly, medicine, particle physics and astrophysics. Traditionally, they are coupled to a photo-multplier (PMT) but now silicon photo-multipliers (SiPM) are…

Instrumentation and Methods for Astrophysics · Physics 2018-09-28 G. Ros , G. Sáez-Cano , G. A. Medina-Tanco , A. D. Supanitsky

Incorrect choice of measuring geometry and signal discrimination thresholds for the BaF2 PAL spectrometer can lead to a significant distortion in the measured spectrum of positron lifetime. The contribution of the distorted events for…

Instrumentation and Detectors · Physics 2015-06-18 L. Yu. Dubov , V. I. Grafutin , Yu. V. Funtikov , Yu. V. Shtotsky , L. V. Elnikova

A systematic study is conducted to understand the coincident resolving time (CRT) for a pair of Lutetium-yttrium oxyorthosilicate (LYSO) and the plastic scintillation detector bars under the Geant4 framework. Crystals are coupled to a…

Instrumentation and Detectors · Physics 2025-10-17 Davinder Siwal , P. K. Mohanty , D. Bose , A. Jain

Positron Annihilation Lifetime Spectroscopy (PALS) allows examining structure of materials in nano and sub-nanometer scale. This technique is based on the lifetime and intensity of ortho-positronium atoms in free volumes of given…

Medical Physics · Physics 2020-01-29 Ewelina Kubicz

Radiation detection is vital for space, medical imaging, homeland security, and environmental monitoring applications. In the past, the Monte Carlo radiation transport toolkit, Geant4, has been employed to enable the effective development…

Instrumentation and Detectors · Physics 2024-10-14 Lysander Miller , Airlie Chapman , Katie Auchettl , Jeremy M. C. Brown

Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a…

In this work, the simulation of optical photons is carried out in an antineutrino detector module consisting of a plastic scintillator connected to light guides and photomultipliers on both ends, which is considered to be used for remote…

Instrumentation and Detectors · Physics 2018-05-23 Mustafa Kandemir , Altan Cakir

A new type of neutron detector, named Stack Structure Solid organic Scintillator (S$^4$), consisting of multi-layer plastic scintillators with capability to suppress low-energy $\gamma$ rays under high-counting rate has been constructed and…

Positron Annihilation Lifetime Spectroscopy (PALS) is a well-established non-destructive technique used for nanostructural characterization of porous materials. It is based on the annihilation of a positron and an electron. Mean positron…

We are designing an all-scintillator Compton gamma imager for use in security investigations and remediation actions involving radioactive threat material. To satisfy requirements for a rugged and portable instrument, we have chosen solid…

Instrumentation and Detectors · Physics 2009-06-28 L. E. Sinclair , D. S. Hanna , A. M. L. MacLeod , P. R. B. Saull

Simulations of photon propagation in scintillation detectors were performed with the aim to find the optimal scintillator geometry, surface treatment, and shape of external reflector in order to achieve maximum light collection efficiency…

Instrumentation and Detectors · Physics 2014-11-25 F. A. Danevich , V. V. Kobychev , R. V. Kobychev , H. Kraus , V. B. Mikhailik , V. M. Mokina , I. M. Solsky

Imaging the features of a sample using Positron Annihilation Spectroscopy (PAS) is currently achieved by rastering, i.e. by scanning the sample surface with a sharply focused positron beam. However, a beam of arbitrary shape (sculpted beam)…

Instrumentation and Detectors · Physics 2024-02-05 Francesco Guatieri

Positron Emission Tomography (PET) is a Nuclear Medicine technique that creates images that allow the study of metabolic activity and organ function using radiopharmaceuticals. Continuous improvement of scintillation detectors for radiation…

Samples of uterine leiomyomatis and normal tissues taken from patients after surgery were investigated using the Positron Annihilation Lifetime Spectroscopy (PALS). Significant differences in all PALS parameters between normal and diseased…

In this contribution we describe a novel solution for the construction of Positron Emission Tomograph. We present the device allowing for determination of the impact position as well as time and deph of interaction of the annihilation gamma…

Medical Physics · Physics 2013-10-15 P. Moskal , P. Salabura , M. Silarski , J. Smyrski , J. Zdebik , M. Zieliński

Proportional scintillation counters (PSCs), both single- and dual-phase, can measure the scintillation (S1) and ionization (S2) channels from particle interactions within the detector volume. The signal obtained from these detectors depends…

Instrumentation and Detectors · Physics 2016-03-23 Kareem Kazkaz , Tenzing Henry Yatish Joshi

Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpose of the performed measurements is to compare the…

Detailed characterization of the newly available plastic scintillator (EJ-299-33A) having the pulse shape discrimination (PSD) property has been carried out in case of a large-sized detector (5 in.$\times$5 in.). The pulse height response…

Instrumentation and Detectors · Physics 2020-12-08 Pratap Roy , K. Banerjee , A. K. Saha , C. Bhattacharya , J. K. Meenaa , P. Bhaskar , S. Mukhopadhyay , S. Bhattacharya
‹ Prev 1 2 3 10 Next ›