Related papers: On an Analytical Inversion Formula for the Modulo …
We find a new and simple inversion formula of the Radon transform RT with the only use of the shearlet system and of well-known properties of RT. No intertwining relation of differential operators in Euclidean space and Radon domain is…
Promoted by the advent of coherent synchrotron light sources, phase contrast tomography allows to resolve three-dimensional variations of an unknown sample's complex refractive index from scattering intensities recorded at different…
A new numerical method for X-ray tomography for a specific case of incomplete Radon data is proposed. Potential applications are in checking out bulky luggage in airports. This method is based on the analysis of the transport PDE governing…
Novel analysis of finite dimensional Hilbert space is outlined. The approach bypasses general, inherent, difficulties present in handling angular variables in finite dimensional problems: The finite dimensional, d, Hilbert space operators…
Ultrawideband radar is an attractive technology for a variety of applications including security systems. As such, it is essential to develop low-cost systems that produce clear target images. Electromagnetic inverse scattering with…
We give an exact inversion formula for the approximate discrete Radon transform introduced in [Brady, SIAM J. Comput., 27(1), 107--119] that is of cost $O(N \log N)$ for a square 2D image with $N$ pixels and requires only partial data.
Tomography is a central tool in medical applications, allowing doctors to investigate patients' interior features. The Radon transform (in two dimensions) is commonly used to model the measurement process in parallel-beam CT. Suitable…
The spherical means Radon transform $\mathcal{M}f(x,r)$ is defined by the integral of a function $f$ in $\mathbb{R}^{n}$ over the sphere $S(x,r)$ of radius $r$ centered at a $x$, normalized by the area of the sphere. The problem of…
The state-of-the-art automotive radars employ multidimensional discrete Fourier transforms (DFT) in order to estimate various target parameters. The DFT is implemented using the fast Fourier transform (FFT), at sample and computational…
Usual modal analysis techniques are based on the Fourier transform. Due to the Delta T . Delta f limitation, they perform poorly when the modal overlap mu exceeds 30%. A technique based on a high-resolution analysis algorithm and an…
Autoencoders have been recently used for encoding medical images. In this study, we design and validate a new framework for retrieving medical images by classifying Radon projections, compressed in the deepest layer of an autoencoder. As…
Magneto-Acousto-Electric Tomography (MAET), also known as the Lorentz force or Hall effect tomography, is a novel hybrid modality designed to be a high-resolution alternative to the unstable Electrical Impedance Tomography. In the present…
We give an algorithm for reversion of formal power series, based on an efficient way to implement the Lagrange inversion formula. Our algorithm requires $O(n^{1/2}(M(n) + MM(n^{1/2})))$ operations where $M(n)$ and $MM(n)$ are the costs of…
We present a new iterative rotation inversion technique based on the Simultaneous Algebraic Reconstruction Technique developed for image reconstruction. We describe in detail our algorithmic implementation and compare it to the classical…
In this paper we introduce and study a Bargmann-Radon transform on the real monogenic Bargmann module. This transform is defined as the projection of the real Bargmann module on the closed submodule of monogenic functions spanned by the…
Limited-angle computerized tomography stands for one of the most difficult challenges in imaging. Although it opens the way to faster data acquisition in industry and less dangerous scans in medicine, standard approaches, such as the…
Many known Radon-type transforms of symmetric (radial or zonal) functions are represented by one-dimensional Riemann-Liouville fractional integrals or their modifications. The present article contains new examples of such transforms in the…
The recent application of Fourier Based Iterative Reconstruction Method (FIRM) has made it possible to achieve high-quality 2D images from a fan beam Computed Tomography (CT) scan with a limited number of projections in a fast manner. The…
Proton radiography is an important diagnostic method for laser plasma experiments, and is particularly important in the analysis of magnetized plasmas. The theory of radiographic image analysis has heretofore only permitted somewhat limited…
This work characterizes the range of the single-quadrant approximate discrete Radon transform (ADRT) of square images. The characterization follows from a set of linear constraints on the codomain. We show that for data satisfying these…