English
Related papers

Related papers: YSO implantation detector for beta-delayed neutron…

200 papers

A newly developed segmented YSO scintillator detector was implemented for the first time at the RI-beam Factory at RIKEN Nishina Center as an implantation-decay counter. The results from the experiment demonstrate that the detector is a…

Organic scintillators are widely used for fast neutron detection and spectroscopy. Several effects complicate the interpretation of results from detectors based upon these materials. First, fast neutrons will often leave a detector before…

Instrumentation and Detectors · Physics 2009-10-29 N. S. Bowden , P. Marleau , J. T. Steele , S. Mrowka , G. Aigeldinger , W. Mengesha

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…

The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator…

The $\beta$-delayed neutron emission in the $^{85, 86}$As $\beta$-decays has been measured at the Ion Guide Isotope Separator On Line facility of the Accelerator Laboratory of the University of Jyv\"askyl\"a. The complete $\beta$-decays…

To study the dependence of the equation of state of high density nuclear matter on the term characterizing the isospin (proton-neutron) asymmetry of nuclear matter, it is necessary to measure azimuthal flow of neutrons as well as azimuthal…

High Energy Physics - Experiment · Physics 2023-10-10 F. Guber , A. Ivashkin , N. Karpushkin , A. Makhnev , S. Morozov , D. Serebryakov , V. Baskov , V. Polyansky

An efficient neutron detection system with good energy resolution is required to correctly characterize decays of neutron-rich nuclei where $\beta-$delayed neutron emission is a dominant decay mode. The Neutron dEtector with Xn Tracking…

Plastic scintillation detectors for Time-of-Flight (TOF) measurements are almost essential for event-by-event identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of 50 $\times$ 50 $\times$…

We have developed a photon counting detector system for combined neutron and gamma radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator…

Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified…

A new high-precision detector for studying neutrons from beta-delayed neutron emission and direct reaction studies is proposed. The Neutron dEtector with Xn Tracking (NEXT) array is designed to maintain high intrinsic neutron detection…

The decays of the $\beta$-delayed neutron emitters $^{137}$I and $^{95}$Rb have been studied with the total absorption $\gamma$-ray spectroscopy technique. The purity of the beams provided by the JYFLTRAP Penning trap at the ion guide…

Calibration of three scintillators (EJ232Q, BC422Q and EJ410) in a time-of-flight (TOF) arrangement using a laser drive-neutron source is presented. The three plastic scintillator detectors were calibrated with gamma insensitive bubble…

This letter explains a new, highly sensitive method for the detection of neutrons, which uses the T$_{1/2}=845$ ns delay in the decay of $^{128}$I at the 137.8 keV energy level, resulting from the capture of thermal neutrons by iodine…

Instrumentation and Detectors · Physics 2017-03-08 E. Yakushev , S. Rozov , A. Drokhlyansky , D. Filosofov , Z. Kalaninova , V. Timkin , D. Ponomarev

Position sensitive detectors based on gaseous scintillation proportional counters with Anger-type readout are being used in several research areas such as neutron detection, search for dark matter and neutrinoless double beta decay. Design…

Instrumentation and Detectors · Physics 2016-01-20 L. Pereira , L. M. S. Margato , A. Morozov , V. Solovov , F. A. F. Fraga

A neutron spectrometer, the European Low-Energy Neutron Spectrometer (ELENS), has been constructed to study exotic nuclei in inverse-kinematics experiments. The spectrometer, which consists of plastic scintillator bars, can be operated in…

This paper presents the model-based design and evaluation of an instrument that estimates incident neutron direction using the kinematics of neutron scattering by hydrogen-1 nuclei in an organic scintillator. The instrument design uses a…

Instrumentation and Detectors · Physics 2017-12-13 Kyle Weinfurther , John Mattingly , Erik Brubaker , John Steele

The neutron long counter NERO was built at the National Superconducting Cyclotron Laboratory (NSCL), Michigan State University, for measuring beta-delayed neutron-emission probabilities. The detector was designed to work in conjunction with…

This study presents a new concept of segmented antineutrino detector based on hexagonal plastic scintillator bars for detecting antineutrinos from a nuclear reactor core. The choice of hexagonal scintillator bars is original and provides…

Instrumentation and Detectors · Physics 2019-12-18 Mustafa Kandemir , Altan Cakir

We have developed image intensifier tubes with delay-anode read-out for time- and position-sensitive photon counting. The timing precision is better than 1 ns with 1000x1000 pixels position resolution and up to one megacounts/s processing…

Instrumentation and Detectors · Physics 2009-11-13 O. Jagutzki , V. Dangendorf , R. Lauck , A. Czasch , J. Milnes
‹ Prev 1 2 3 10 Next ›