Related papers: Multi-IMPT: a biologically equivalent approach to …

200 papers

Intensity modulated proton therapy (IMPT) provides highly conformal dose distributions through the application of multiple, angularly spaced fields, each applying an ad-hoc pattern of spatially varying particle fluences. In particular,…

Medical Physics · Physics 2017-03-10 F. Arcadu

We developed a novel method of creating intensity modulated proton arc therapy (IMPAT) plans that uses computing resources efficiently and may offer a dosimetric benefit for patients with ependymoma or similar tumor geometries. Our IMPAT…

Background and purpose: IMPT faces challenges in lung cancer treatment, like maintaining plan robustness for moving tumors against setup, range errors, and interplay effects. Proton Arc Therapy (PAT) is an alternative to maintain target…

Purpose: To demonstrate the feasibility of fast Monte Carlo (MC) based inverse biological planning for the treatment of head and neck tumors in spot-scanning proton therapy. Methods: Recently, a fast and accurate Graphics Processor Unit…

Medical Physics · Physics 2016-10-11 H. Wan Chan Tseung , J. Ma , C. R. Kreofsky , D. Ma , C. Beltran

Background: Multi-collimator proton minibeam radiation therapy (MC-pMBRT) has recently emerged as a versatile technique for dose shaping, enabling peak-valley dose patterns in organs-at-risk (OAR) while maintaining a uniform dose…

Medical Physics · Physics 2025-02-25 Nimita Shinde , Weijie Zhang , Yuting Lin , Hao Gao

Purpose: Patient-specific ridge filters can modulate proton energy to obtain a conformal dose. We describe a new framework for optimization of filter design and spot maps to meet the unique demands of FLASH radiotherapy. We demonstrate an…

Purpose:The recently proposed IPO-IMPT framework allows simultaneous optimization of dose, dose rate, and LET for FLASH treatment planning. Finding solutions to IPO-IMPT is difficult due to computational intensiveness. Nevertheless, an…

We summarize recent results and ongoing activities in mathematical algorithms and computer science methods related to proton computed tomography (pCT) and intensity-modulated particle therapy (IMPT) treatment planning. Proton therapy…

Medical Physics · Physics 2021-08-24 Yair Censor , Keith E. Schubert , Reinhard W. Schulte

Intensity-modulated proton therapy (IMPT) offers superior dose conformity with reduced exposure to surrounding healthy tissues compared to conventional photon therapy. Improving IMPT delivery efficiency reduces motion-related uncertainties,…

Medical Physics · Physics 2025-04-15 Ya-Nan Zhu , Nimita Shinde , Bowen Lin , Hao Gao

Background: Intensity-modulated proton therapy (IMPT) using pencil beam technique scans tumor in a layer by layer, then spot by spot manner. It can provide highly conformal dose to tumor targets and spare nearby organs-at-risk (OAR). Fast…

Medical Physics · Physics 2024-11-28 Aoxiang Wang , Ya-Nan Zhu , Jufri Setianegara , Yuting Lin , Peng Xiao , Qingguo Xie , Hao Gao

We present a method to include robustness into a multi-criteria optimization (MCO) framework for intensity-modulated proton therapy (IMPT). The approach allows one to simultaneously explore the trade-off between different objectives as well…

Medical Physics · Physics 2015-06-03 Wei Chen , Jan Unkelbach , Alexei Trofimov , Thomas Madden , Hanne Kooy , Thomas Bortfeld , David Craft

Purpose: To evaluate automated multicriteria optimization (MCO)-- designed for intensity modulated radiation therapy (IMRT), but invoked with limited segmentation -- to efficiently produce high quality 3D conformal treatment (3D-CRT) plans.…

Medical Physics · Physics 2014-02-03 Fazal Khan , David Craft

A central problem in the field of radiation therapy (RT) is how to optimally deliver dose to a patient in a way that fully accounts for anatomical position changes over time. As current RT is a static process, where beam intensities are…

Medical Physics · Physics 2019-09-04 Rodney D. Wiersma , Xinmin Liu

Purpose: Intensity-modulated proton therapy (IMPT) offers precise tumor coverage while sparing organs at risk (OARs) in head and neck (H&N) cancer. However, its sensitivity to anatomical changes requires frequent adaptation through online…

Stereotactic body radiotherapy (SBRT) is characterized by delivering a high amount of dose in a short period of time. In SBRT the dose is delivered using open fields (e.g., beam's-eye-view) known as "apertures". Mathematical methods can be…

Medical Physics · Physics 2015-06-15 Hamed Yarmand , David Craft

Purpose: We aims to examine the impact of different head tilt angles on the dose distribution in the whole-brain target area and organs at risk. It also aims to determine the head tilt angle to achieve optimal radiation therapy outcomes.…

Medical Physics · Physics 2024-06-03 Cuiyun Yuan , Sisi Xu , Yang Li , Enzhuo Quan , Dongjie Chen , Jun Liang , Chenbin Liu

Purpose: Proton therapy provides superior dose conformity compared to photon therapy, but its treatment planning is challenged by sensitivity to anatomical changes, setup/range uncertainties, and computational complexity. This review…

Objective. As proton arc therapy (PAT) approaches clinical implementation, optimizing treatment plans for this innovative delivery modality remains challenging, especially in addressing arc delivery time. Existing algorithms for minimizing…

Medical Physics · Physics 2024-10-11 S. Wuyckens , G. Janssens , M. Chocan Vera , J. Sundstrom , D. Di Perri , E. Sterpin , K. Souris , J. A. Lee

The purpose of this study was to use various dosimetrical indices to determine the best IMRT modality technique for treating patients with prostate cancer. Ten patients with prostate cancer were included in this study. Intensity modulated…

Robust optimization is a commonly employed method to mitigate uncertainties in the planning of intensity-modulated proton therapy (IMPT). In certain contexts, the large number of uncertainty scenarios makes the robust problem impractically…

Medical Physics · Physics 2025-04-22 Ivar Bengtsson