English
Related papers

Related papers: Radon emanation rate measurements using liquid sci…

200 papers

There has been an increasing interest in the monitoring of nuclear fuel for power reactors by detecting the anti-neutrinos produced during operation. Small liquid scintillator detectors have already demonstrated sensitivity to operational…

Instrumentation and Detectors · Physics 2007-05-23 R. W. McKeown , D. E. Reyna

We present a new conceptual radiation detector, the Architected Multimaterial Scintillator System, that utilizes a scintillator composed of multiple materials arranged in architected structures to enable new capabilities. By structuring…

Instrumentation and Detectors · Physics 2021-03-11 Xianyi Zhang , Jason Philip Brodsky , Elaine Lee , Andrew Neil Mabe , Dominique Porcincula

A full simulation of a transition radiation detector (TRD) based on the GEANT, GARFIELD, MAGBOLTZ and HEED codes has been developed. This simulation can be used to study and develop TRD for high energy particle identification using either…

Computational Physics · Physics 2016-09-08 M. N. Mazziotta

Radiation detection is vital for space, medical imaging, homeland security, and environmental monitoring applications. In the past, the Monte Carlo radiation transport toolkit, Geant4, has been employed to enable the effective development…

Instrumentation and Detectors · Physics 2024-10-14 Lysander Miller , Airlie Chapman , Katie Auchettl , Jeremy M. C. Brown

We report measurement of reactor based electron anti-neutrinos from a prototype array of plastic scintillator bars ( mini-ISMRAN ) located inside Dhruva research reactor hall, BARC. The detector setup took data for 128 days for reactor on…

Nuclear Experiment · Physics 2021-12-30 P. K. Netrakanti , D. Mulmule , D. K. Mishra , S. P. Behera , R. Dey , R. Sehgal , S. K. Sinha , V. Jha , L. M. Pant

Purpose: To demonstrate a proton imaging system based on well-established fast scintillator technology to achieve high performance with low cost and complexity, with the potential of a straightforward translation into clinical use. Methods:…

We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column is integrated into the gas purification loop of the XENON100 detector for online radon…

Instrumentation and Detectors · Physics 2017-06-05 XENON Collaboration , E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , F. D. Amaro , M. Anthony , F. Arneodo , P. Barrow , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , L. Bütikofer , J. Calvén , J. M. R. Cardoso , M. Cervantes , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , P. de Perio , P. Di Gangi , A. Di Giovanni , S. Diglio , E. Duchovni , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , D. Franco , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , C. Geis , L. W. Goetzke , L. Grandi , Z. Greene , C. Grignon , C. Hasterok , E. Hogenbirk , R. Itay , B. Kaminsky , G. Kessler , A. Kish , H. Landsman , R. F. Lang , D. Lellouch , L. Levinson , M. Le Calloch , Q. Lin , S. Lindemann , M. Lindner , J. A. M. Lopes A. Manfredini , I. Maris , T. Marrodán Undagoitia , J. Masbou , F. V. Massoli , D. Masson , D. Mayani , Y. Meng , M. Messina , K. Micheneau , B. Miguez , A. Molinario , M. Murra , J. Naganoma , K. Ni , U. Oberlack , S. E. A. Orrigo , P. Pakarha , B. Pelssers , R. Persiani , F. Piastra , J. Pienaar , M. -C. Piro , V. Pizzella , G. Plante , N. Priel , L. Rauch , S. Reichard , C. Reuter , A. Rizzo , S. Rosendahl , N. Rupp , R. Saldanha , J. M. F. dos Santos , G. Sartorelli , M. Scheibelhut , S. Schindler , J. Schreiner , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , E. Shockley , M. Silva , H. Simgen , M. v. Sivers , A. Stein , D. Thers , A. Tiseni , G. Trinchero , C. Tunnell , N. Upole , H. Wang , Y. Wei , C. Weinheimer , J. Wulf , J. Ye , Y. Zhang , I. Cristescu

Neutron veto detector based on liquid scintillator containing hydrogen atoms is an integral part of any underground experiment for dark matter search. So far, a flammable mixture of liquid hydrocarbons was used as a liquid scintillator in…

Instrumentation and Detectors · Physics 2020-07-06 A. Bondar , E. Borisova , A. Buzulutskov , E. Frolov , V. Nosov , V. Oleynikov , A. Sokolov

A semiconductor tracker for muon scattering tomography is presented. The tracker contains silicon strip sensors with an $80\,\mu$m pitch, precision mechanics and integrated cooling. The electronic readout of the sensors is performed by a…

Instrumentation and Detectors · Physics 2018-10-30 F. Keizer , A. Gorbatch , M. A. Parker , C. Steer , S. A. Wotton

Scintillator doped with a high neutron-capture cross-section material can be used to detect neutrons via their resulting gamma rays. Examples of such detectors using liquid scintillator have been successfully used in high-energy physics…

Instrumentation and Detectors · Physics 2019-01-01 D. M. Poehlmann , D. Barker , H. Chagani , P. Cushman , G. Heuermann , A. Medved , H. E. Rogers , R. Schmitz

PETALO (a Positron Emission Tof Apparatus based on Liquid xenOn) is a new approach for Positron Emission Tomography scanners, based on liquid xenon. The PETALO detector aims at capturing the light produced by the scintillation in LXe taking…

We carried out a study of neutrino detection at the experimental fast reactor JOYO using a 0.76 tons gadolinium loaded liquid scintillator detector. The detector was set up on the ground level at 24.3m from the JOYO reactor core of 140MW…

We review the basic features of transition radiation and how they are used for the design of modern Transition Radiation Detectors (TRD). The discussion will include the various realizations of radiators as well as a discussion of the…

Instrumentation and Detectors · Physics 2015-06-03 A. Andronic , J. P. Wessels

In order to cope with increasing lifetime radiation damage expected at collider experiments, silicon sensors are becoming increasingly thin. To achieve adequate detection efficiency, the next generation of detectors may have to operate with…

Instrumentation and Detectors · Physics 2020-08-28 Patrick McCormack , Maurice Garcia-Sciveres , Timon Heim , Benjamin Nachman , Magne Lauritzen

The midsize single-phase liquid argon prototype detector, operating at the surface laboratory, is designed to measure scintillation light emitted by the liquid argon (LAr). The detector employs 42 8-inch photomultiplier tubes (PMT) to…

Instrumentation and Detectors · Physics 2023-08-22 K. K. Zhao , M. Y. Guan , J. C. Liu , C. G. Yang , S. T. Lin

We present new measurements of the scintillation and ionization yields in liquid xenon for low energy electronic (about 3--7 keV$_{ee}$) and nuclear recoils (about 8--20 keV$_{nr}$) at different drift fields from 236 V/cm to 3.93 kV/cm,…

Instrumentation and Detectors · Physics 2015-08-19 Qing Lin , Jialing Fei , Fei Gao , Jie Hu , Yuehuan Wei , Xiang Xiao , Hongwei Wang , Kaixuan Ni

The radioactive daughters isotope of 222Rn are one of the highest risk contaminants in liquid xenon detectors aiming for a small signal rate. The noble gas is permanently emanated from the detector surfaces and mixed with the xenon target.…

Instrumentation and Detectors · Physics 2018-03-14 Natascha Rupp

Proportional scintillation in liquid xenon has a promising application in the field of direct dark matter detection, potentially allowing for simpler, more sensitive detectors. However, knowledge of the basic properties of the phenomenon as…

Instrumentation and Detectors · Physics 2014-11-11 E. Aprile , H. Contreras , L. W. Goetzke , A. J. Melgarejo Fernandez , M. Messina , J. Naganoma , G. Plante , A. Rizzo , P. Shagin , R. Wall

The Jiangmen Underground Neutrino Observatory is building the world's largest liquid scintillator detector with a 20 kt target mass and about 700 m overburden. The total underground space of civil construction is about 300,000 m$^3$ with…

Instrumentation and Detectors · Physics 2026-03-05 Chenyang Cui , Jie Zhao , Gaosong Li , Yongpeng Zhang , Cong Guo , Zhenning Qu , Yifang Wang , Xiaonan Li , Liangjian Wen , Miao He , Monica Sisti

Air radon concentration measurement is useful for research on geophysical effects, but it is strongly sensitive to site geology and many geophysical and microclimatic processes such as wind, ventilation, air humidity and so on that induce…

‹ Prev 1 3 4 5 6 7 10 Next ›