Related papers: Radon emanation rate measurements using liquid sci…
The XENONnT experiment has achieved an exceptionally low $^\text{222}$Rn activity concentration within its inner 5.9$\,$tonne liquid xenon detector of (0.90$\,\pm\,$0.01$\,$stat.$\,\pm\,$0.07 sys.)$\,\mu$Bq/kg, equivalent to about 430…
A high-flow radon removal system based on cryogenic distillation was developed and constructed to reduce radon-induced backgrounds in liquid xenon detectors for rare event searches such as XENONnT. A continuous purification of the XENONnT…
Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly…
We classify Radon stationary measures for a random walk on $\mathbb{T}^d \times \mathbb{R}$. This walk is realised by a random action of $SL_{d}(\mathbb{Z})$ on the $\mathbb{T}^d$ component, coupled with a translation on the $\mathbb{R}$…
Radon is the main background source of dark matter and neutrino experiments. Radon concentration ($\rm mBq/m^3$) measurement by liquid scintillation detector is a highly sensitive method at low temperatures using silicon photomultipliers…
To precisely measure radon concentrations in purified air supplied to the Super-Kamiokande detector as a buffer gas, we have developed a highly sensitive radon detector with an intrinsic background as low as 0.33$\pm$0.07 mBq/m$^{3}$. In…
In the evaluation of novel scintillators, it is important to ensure that the spectrum of the light emitted by the scintillator is well matched to the response of the photomultiplier. In attempting to measure this spectrum using radioactive…
A simple model for the estimation of the light yield of a scintillation detector is developed under general assumptions and relying exclusively on the knowledge of its optical properties. The model allows to easily incorporate effects…
The removal of Radon induced Lead from liquid scintillator was extensively studied in preparation for KamLAND's low background phase. This work presents the results from laboratory experiments performed at the University of Alabama and…
The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron…
The amount of radioactive impurities contaminated in the detector gases is required to be kept at a very low level for rare event particle physics such as dark matter and neutrino observation experiments. Zeolite is a well-known class of…
Radon is a naturally occurring radioactive gas that contributes significantly to human radiation exposure and must be controlled to avoid concentrations harmful to health. The paper presents an impulse-proportional ionization chamber that…
The activity of $^{222}$Rn and its daughter isotopes was measured in the air of several underground laboratories of the Baksan Neutrino Observatory at various distances from the entrance. The measurements were carried out with the help of…
The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities.…
We developed a highly sensitive, reliable and portable automatic system (H$^{3}$) to monitor the radon concentration of the underground experimental halls of the Daya Bay Reactor Neutrino Experiment. H$^{3}$ is able to measure radon…
The selection of low-radioactive construction materials is of utmost importance for the success of low-energy rare event search experiments. Besides radioactive contaminants in the bulk, the emanation of radioactive radon atoms from…
We developed a 12-liter volume neutron detector filled with the liquid scintillator EJ301 that measures neutrons in an underground laboratory where dark matter and neutrino experiments are located. The detector target is a cylindrical…
An active device for radon detection in the air was developed. The monitor operates in pulse counting mode for real-time continuous measurements. The presented prototype has a relatively simple design made of low-price and easy to acquire…
Liquid argon is being employed as a detector medium in neutrino physics and Dark Matter searches. A recent push to expand the applications of scintillation light in Liquid Argon Time Projection Chamber neutrino detectors has necessitated…
We present a measurement of scintillation efficiency for a few tens of keV nuclear recoils (NR) with a liquid argon time projection chamber under electric fields ranging from $0$ to $3\ {\rm kV/cm}$. The calibration data are taken with…