Related papers

Related papers: Synergistic PET/CT Reconstruction Using a Joint Ge…

200 papers

Positron Emission Tomography (PET) image reconstruction is inherently challenged by Poisson noise and physical degradation factors, which are further exacerbated in limited-angle acquisitions. While deep learning methods demonstrate…

Computer Vision and Pattern Recognition · Computer Science 2026-05-11 Rüveyda Yilmaz , Yuli Wu , Johannes Stegmaier , Volkmar Schulz

PET suffers from a low signal-to-noise ratio. Meanwhile, the k-space data acquisition process in MRI is time-consuming by PET-MRI systems. We aim to accelerate MRI and improve PET image quality. This paper proposed a novel joint…

Computer Vision and Pattern Recognition · Computer Science 2024-08-23 Taofeng Xie , Zhuoxu Cui , Congcong Liu , Chen Luo , Huayu Wang , Yuanzhi Zhang , Xuemei Wang , Yihang Zhou , Qiyu Jin , Guoqing Chen , Dong Liang , Haifeng Wang

We developed a positron emission tomography (PET) system for multiple-isotope imaging. Our PET system, named multiple-isotope PET (MI-PET), can distinguish between different tracer nuclides using coincidence measurement of prompt…

Computed tomography (CT) uses X-ray measurements taken from sensors around the body to generate tomographic images of the human body. Conventional reconstruction algorithms can be used if the X-ray data are adequately sampled and of high…

Image and Video Processing · Electrical Eng. & Systems 2021-12-28 Ruiwen Xing , Thomas Humphries , Dong Si

Computed tomography (CT) can provide a 3D view of the patient's internal organs, facilitating disease diagnosis, but it incurs more radiation dose to a patient and a CT scanner is much more cost prohibitive than an X-ray machine too.…

Image and Video Processing · Electrical Eng. & Systems 2019-05-17 Xingde Ying , Heng Guo , Kai Ma , Jian Wu , Zhengxin Weng , Yefeng Zheng

Convolutional neural networks (CNNs) have recently achieved remarkable performance in positron emission tomography (PET) image reconstruction. In particular, CNN-based direct PET image reconstruction, which directly generates the…

Medical Physics · Physics 2024-10-28 Fumio Hashimoto , Kibo Ote

The ability to synthesise Computed Tomography images - commonly known as pseudo CT, or pCT - from MRI input data is commonly assessed using an intensity-wise similarity, such as an L2-norm between the ground truth CT and the pCT. However,…

Image and Video Processing · Electrical Eng. & Systems 2020-04-15 Kerstin Kläser , Thomas Varsavsky , Pawel Markiewicz , Tom Vercauteren , David Atkinson , Kris Thielemans , Brian Hutton , M Jorge Cardoso , Sebastien Ourselin

Dose reduction in computed tomography (CT) is essential for decreasing radiation risk in clinical applications. Iterative reconstruction is one of the most promising ways to compensate for the increased noise due to reduction of photon…

Image and Video Processing · Electrical Eng. & Systems 2021-03-24 Zhuonan He , Yikun Zhang , Yu Guan , Shanzhou Niu , Yi Zhang , Yang Chen , Qiegen Liu

In this paper, we study the generative models of sequential discrete data. To tackle the exposure bias problem inherent in maximum likelihood estimation (MLE), generative adversarial networks (GANs) are introduced to penalize the…

Machine Learning · Computer Science 2019-05-14 Sidi Lu , Lantao Yu , Siyuan Feng , Yaoming Zhu , Weinan Zhang , Yong Yu

Positron emission tomography (PET) imaging is an imaging modality for diagnosing a number of neurological diseases. In contrast to Magnetic Resonance Imaging (MRI), PET is costly and involves injecting a radioactive substance into the…

Image and Video Processing · Electrical Eng. & Systems 2019-08-23 Haoliang Sun , Ronak Mehta , Hao H. Zhou , Zhichun Huang , Sterling C. Johnson , Vivek Prabhakaran , Vikas Singh

Combined use of PET and dual-energy CT provides complementary information for multi-parametric imaging. PETenabled dual-energy CT combines a low-energy x-ray CT image with a high-energy &\gamma&-ray CT (GCT) image reconstructed from…

Medical Physics · Physics 2021-08-04 Siqi Li , Guobao Wang

Positron emission tomography (PET) is widely used for clinical diagnosis. As PET suffers from low resolution and high noise, numerous efforts try to incorporate anatomical priors into PET image reconstruction, especially with the…

Medical Physics · Physics 2019-12-17 Nuobei Xie , Kuang Gong , Ning Guo , Zhixin Qin , Zhifang Wu , Huafeng Liu , Quanzheng Li

To obtain high-quality positron emission tomography (PET) scans while reducing radiation exposure to the human body, various approaches have been proposed to reconstruct standard-dose PET (SPET) images from low-dose PET (LPET) images. One…

Image and Video Processing · Electrical Eng. & Systems 2023-08-22 Zeyu Han , Yuhan Wang , Luping Zhou , Peng Wang , Binyu Yan , Jiliu Zhou , Yan Wang , Dinggang Shen

Positron Emission Tomography (PET) imaging requires accurate attenuation correction (AC) to account for photon loss due to tissue density variations. In PET/MR systems, computed tomography (CT), which offers a straightforward estimation of…

Image and Video Processing · Electrical Eng. & Systems 2025-04-11 Weijie Chen , James Wang , Alan McMillan

Dynamic total body positron emission tomography (TB-PET) makes it feasible to measure the kinetics of all organs in the body simultaneously which may lead to important applications in multi-organ disease and systems physiology. Since…

Medical Physics · Physics 2026-01-14 Yun Zhao , Qinlin Gu , Georgios I. Angelis , Andrew J. Reader , Yanan Fan , Steven R. Meikle

Computed tomography (CT) equivalent information is needed for attenuation correction in PET imaging and for dose planning in radiotherapy. Prior work has shown that Gaussian mixture models can be used to generate a substitute CT (s-CT)…

Applications · Statistics 2016-09-29 Anders Hildeman , David Bolin , Jonas Wallin , Adam Johansson , Tufve Nyholm , Thomas Asklund , Jun Yu

The radiation dose in computed tomography (CT) examinations is harmful for patients but can be significantly reduced by intuitively decreasing the number of projection views. Reducing projection views usually leads to severe aliasing…

Image and Video Processing · Electrical Eng. & Systems 2022-11-28 Bing Guan , Cailian Yang , Liu Zhang , Shanzhou Niu , Minghui Zhang , Yuhao Wang , Weiwen Wu , Qiegen Liu

Attenuation correction (AC) is necessary for accurate activity quantification in positron emission tomography (PET). Conventional reconstruction methods typically rely on attenuation maps derived from a co-registered computed tomography…

Our aim was to enhance visual quality and quantitative accuracy of dynamic positron emission tomography (PET)uptake images by improved image reconstruction, using sophisticated sparse penalty models that incorporate both 2D spatial+1D…

Computer Vision and Pattern Recognition · Computer Science 2019-06-17 Ida Häggström , Yizun Lin , Si Li , Andrzej Krol , Yuesheng Xu , C. Ross Schmidtlein

The aim of this paper is to test and analyze a novel technique for image reconstruction in positron emission tomography, which is based on (total variation) regularization on both the image space and the projection space. We formulate our…

Numerical Analysis · Mathematics 2014-07-24 Martin Burger , Jahn Müller , Evangelos Papoutsellis , Carola-Bibiane Schönlieb