English
Related papers

Related papers: Exploring Scintillators and Cherenkov Radiators fo…

200 papers

Slow liquid scintillator Cherenkov detectors have been proposed as part of several future neutrino experiments because they can provide both directionality and energy measurements. This feature is expected to enhance the sensitivities for…

Instrumentation and Detectors · Physics 2019-02-18 Ziyi Guo , Minfang Yeh , Rui Zhang , De-Wen Cao , Ming Qi , Zhe Wang , Shaomin Chen

The fast scintillation decay time and the high scintillation yield of liquid xenon makes it an appropriate material for nuclear medicine. Moreover, being a continuous medium with a uniform response, liquid xenon allows one to avoid most of…

A hybrid dual-readout calorimeter concept, comprising both electromagnetic and hadronic sections, has recently been proposed to meet the performance requirements of experiments at future e$^{+}$e$^{-}$ colliders. The front compartment…

Instrumentation and Detectors · Physics 2026-03-20 Andrea Benaglia , Flavia Cetorelli , Marco Toliman Lucchini , Etiennette Auffray , Louis Roux , Julie Delenne

We have developed particle detectors based on fused silica (quartz) Cherenkov radiators read out with micro-channel plate photomultipliers (MCP-PMTs) or silicon photomultipliers (SiPMs) for high precision timing (Sigma(t) about 10-15 ps).…

Instrumentation and Detectors · Physics 2015-06-05 M. G. Albrow , Heejong Kim , S. Los , E. Ramberg , A. Ronzhin , V. Samoylenko , H. Wenzel , A. Zatserklyaniy

The aim of this work is to develop high precision Time-of-Flight (TOF) devices based on high refractive index solid Cherenkov radiators read out by silicon photomultipliers (SiPMs). Cherenkov light is prompt and therefore ideal for reaching…

A compact gamma-ray detector module was developed and characterized for spectroscopic applications across a wide energy range. The detector comprises a 4x4 array of silicon photomultipliers (SiPMs, Hamamatsu MPPC S13360-3050) coupled with…

Instrumentation and Detectors · Physics 2025-10-01 S. Nuruyev , G. Ahmadov , D. Berikov , M. Holik , F. Ahmadov , A. Sadigov , R. Akbarov , J. Naghiyev , I. Nuruyev , A. Mammadli

We report on the separation of Cherenkov and scintillation light in BGO and BSO crystals read out with silicon photomultipliers (SiPMs). The two light components are disentangled on an event-by-event basis by combining optical filtering…

Plastic scintillators are widely used in particle detectors when precise timing information is required. As a basis for comparing different detectors we use such a characteristic as the time resolution per 1MeV detected energy, i.e. the…

Instrumentation and Detectors · Physics 2021-09-08 Alexey Stoykov , Tigran Rostomyan

Halide perovskite semiconductors such as CsPbBr3 (CLB) are emerging gamma-ray detectors for applications requiring very high energy resolution and potential for fine detector segmentation. Semiconductor detectors typically offer poor time…

Dedicated R&D efforts are currently underway to couple a thin Cherenkov radiator to Silicon Photomultiplier (SiPM) arrays for precise charged particle Time-of-Flight (ToF) measurements. The prompt nature of Cherenkov radiation makes it an…

Instrumentation and Detectors · Physics 2026-01-22 M. N. Mazziotta , A. Di Mauro , M. Giliberti , A. Liguori , L. Lorusso , E. Nappi , N. Nicassio , G. Panzarini , R. Pillera , G. Volpe

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…

First of its kind, the barrel section of the MIP Timing Detector is a large area timing detector based on LYSO:Ce crystals and SiPMs which are required to operate in an unprecedentedly harsh radiation environment (up to an integrated…

Instrumentation and Detectors · Physics 2025-08-14 F. Addesa , P. Akrap , A. Albert , B. Allmond , T. Anderson , J. Babbar , D. Baranyai , P. Barria , C. Basile , A. Benaglia , A. Benato , M. Benettoni , M. Besancon , N. Bez , S. Bhattacharya , R. Bianco , D. Blend , A. Boletti , A. Bornheim , R. Bugalho , A. Bulla , B. Cardwell , R. Carlin , M. Casarsa , F. Cetorelli , F. Cossutti , B. Cox , G. Da Molin , F. De Guio , K. De Leo , F. De Riggi , P. Debbins , D. Del Re , R. Delli Gatti , J. Dervan , P. Devouge , K. Dreimanis , O. M. Eberlins , F. Errico , E. Fernandez , W. Funk , A. Gaile , M. Gallinaro , R. Gargiulo , R. Gerosa , A. Ghezzi , B. Gyongyosi , Z. Hao , A. H. Heering , Z. Hu , R. Isocrate , M. Jose , A. Karneyeu , M. S. Kim , A. Krishna , B. Kronheim , O. K. Köseyan , A. Ledovskoy , L. Li , Z. Li , V. Lohezic , F. Lombardi , M. T. Lucchini , M. Malberti , Y. Mao , Y. Maravin , B. Marzocchi , D. Mazzaro , R. Menon Raghunandanan , P. Meridiani , C. Munoz Diaz , Y. Musienko , S. Nargelas , L. L. Narváez , C. Neu , G. Organtini , T. Orimoto , D. Osite , M. Paganoni , S. Palluotto , C. Palmer , N. Palmeri , F. Pandolfi , R. Paramatti , T. Pauletto , A. Perego , G. Pikurs , G. Pizzati , R. Plese , C. Quaranta , G. Reales Gutiérrez , N. Redaelli , S. Ronchi , R. Rossin , M. Ö. Sahin , F. Santanastasio , I. Schmidt , D. Sidiropoulos Kontos , T. Sievert , R. Silva , P. Simmerling , L. Soffi , P. Solanki , G. Sorrentino , M. Spiropulu , N. R. Strautnieks , X. Sun , D. D. Szabo , T. Tabarelli de Fatis , G. Tamulaitis , R. Taylor , M. Titov , M. Tosi , G. Trabucco , A. Tsirou , C. Tully , M. Turcato , B. Ujvari , J. Varela , F. Veronese , V. Vladimirov , J. Wang , M. Wayne , S. White , Z. Wu , J. W. Wulff , R. A. Wynne , L. Zhang , M. Zhang , G. Zilizi

We study the possibility to use the Cherenkov light for the efficient detection of 511 keV photons with the goal to use it in TOF-PET. We designed and tested two detection modules consisting of PbF$_2$ crystals attached to Planacon MCP-PMT…

Instrumentation and Detectors · Physics 2020-03-24 C. Canot , M. Alokhina , P. Abbon , J. P. Bard , D. Breton , E. Delagnes , J. Maalmi , G. Tauzin , D. Yvon , V. Sharyy

In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6 cm x 1…

Instrumentation and Detectors · Physics 2017-12-19 C. Betancourt , A. Blondel , R. Brundler , A. Datwyler , Y. Favre , D. Gascon , S. Gomez , A. Korzenev , P. Mermod , E. Noah , N. Serra , D. Sgalaberna , B. Storaci

Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing…

Instrumentation and Detectors · Physics 2016-04-19 J. W. Zhao , B. H. Sun , I. Tanihata , S. Terashima , L. H. Zhu , A. Enomoto , D. Nagae , T. Nishimura , S. Omika , A. Ozawa , Y. Takeuchi , T. Yamaguchi

Liquid xenon offers several features, which make it suitable for applications in nuclear medicine, such as high scintillation yield and fast scintillation decay time. Moreover, being a continuous medium with a uniform response, liquid xenon…

Instrumentation and Detectors · Physics 2021-03-02 Carmen Romo-Luque

The ability to separately identify the Cherenkov and scintillation light components produced in scintillating mediums holds the potential for a major breakthrough in neutrino detection technology, allowing development of a large,…

Instrumentation and Detectors · Physics 2017-10-10 J. Caravaca , F. B. Descamps , B. J. Land , J. Wallig , M. Yeh , G. D. Orebi Gann

The timing and spectral characteristics of four highly efficient, slow fluors are presented for liquid scintillator solutions using linear alkylbenzene (LAB) as the primary solvent. The mixtures exhibit high light yields, but with rise…

Instrumentation and Detectors · Physics 2020-05-26 Steven D. Biller , Edward J. Leming , Josephine L. Paton

The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of…

Instrumentation and Detectors · Physics 2021-07-19 R. Abbott , A. Abreu , F. Addesa , M. Alhusseini , T. Anderson , Y. Andreev , A. Apresyan , R. Arcidiacono , M. Arenton , E. Auffray , D. Bastos , L. A. T. Bauerdick , R. Bellan , M. Bellato , A. Benaglia , M. Benettoni , R. Bertoni , M. Besancon , S. Bharthuar , A. Bornheim , E. Brücken , J. N. Butler , C. Campagnari , M. Campana , R. Carlin , P. Carniti , N. Cartiglia , M. Casarsa , O. Cerri , P. Checchia , H. Chen , S. Chidzik , F. Chlebana , F. Cossutti , M. Costa , B. Cox , I. Dafinei , F. De Guio , P. Debbins , D. del Re , A. Dermenev , E. Di Marco , K. Dilsiz , K. F. Di Petrillo , G. Dissertori , S. Dogra , U. Dosselli , I. Dutta , F. Caleb , C. Fernandez Madrazo , M. Fernandez , M. Ferrero , Z. Flowers , W. Funk , M. Gallinaro , S. Ganjour , M. Gardner , F. Geurts , A. Ghezzi , S. Gninenko , F. Golf , J. Gonzalez , C. Gotti , L. Gray , F. Guilloux , S. Gundacker , E. Hazen , S. Hedia , A. Heering , R. Heller , T. Isidori , R. Isocrate , R. Jaramillo , M. Joyce , K. Kaadze , A. Karneyeu , H. Kim , J. King , G. Kopp , M. Korjik , O. K. Koseyan , A. Kozyrev , N. Kratochwil , M. Lazarovits , A. Ledovskoy , H. Lee , J. Lee , A. Li , S. Li , W. Li , T. Liu , N. Lu , M. Lucchini , W. Lustermann , C. Madrid , M. Malberti , I. Mandjavize , J. Mao , Y. Maravin , D. Marlow , B. Marsh , P. Martinez del Arbol , B. Marzocchi , R. Mazza , C. McMahon , V. Mechinsky , P. Meridiani , A. Mestvirishvili , N. Minafra , A. Mohammadi , F. Monti , C. S. Moon , R. Mulargia , M. Murray , Y. Musienko , J. Nachtman , S. Nargelas , L. Narvaez , O. Neogi , C. Neu , T. Niknejad , M. Obertino , H. Ogul , G. Oh , I. Ojalvo , Y. Onel , G. Organtini , T. Orimoto , J. Ott , I. Ovtin , M. Paganoni , F. Pandolfi , R. Paramatti , A. Peck , C. Perez , G. Pessina , C. Pena , S. Pigazzini , O. Radchenko , N. Redaelli , D. Rigoni , E. Robutti , C. Rogan , R. Rossin , C. Rovelli , C. Royon , M. Ö. Sahin , W. Sands , F. Santanastasio , U. Sarica , I. Schmidt , R. Schmitz , J. Sheplock , J. C. Silva , F. Siviero , L. Soffi , V. Sola , G. Sorrentino , M. Spiropulu , D. Spitzbart , A. G. Stahl Leiton , A. Staiano , D. Stuart , I. Suarez , T. Tabarelli de Fatis , G. Tamulaitis , Y. Tang , B. Tannenwald , R. Taylor , E. Tiras , M. Titov , S. Tkaczyk , D. Tlisov , I. Tlisova , M. Tornago , M. Tosi , R. Tramontano , J. Trevor , C. G. Tully , B. Ujvari , J. Varela , S. Ventura , I. Vila , T. Wamorkar , C. Wang , X. Wang , M. Wayne , J. Wetzel , S. White , D. Winn , S. Wu , S. Xie , Z. Ye , G. B. Yu , G. Zhang , L. Zhang , Y. Zhang , Z. Zhang , R. Zhu

We study the light output, light collection efficiency and signal timing of a variety of organic scintillators that are being considered for the upgrade of the hadronic calorimeter of the CMS detector. The experimental data are collected at…

Instrumentation and Detectors · Physics 2018-02-14 HCAL collaboration
‹ Prev 1 2 3 10 Next ›