English
Related papers

Related papers: PICOSEC-Micromegas Detector, an innovative solutio…

200 papers

A muon tracking system consisting of four 9cm x 10cm sized bulk Micromegas detectors with 128um amplification-gap and two 10cm x 10cm triple GEM detectors is foreseen for high-precision tracking of 140GeV muons at the H8 beamline at CERN…

Instrumentation and Detectors · Physics 2015-06-03 Jonathan Bortfeldt , Otmar Biebel , David Heereman , Ralf Hertenberger

UV lasers for the calibration of gaseous detectors have seen newfound employment with current-generation micro-pattern gaseous detectors (MPGDs), especially those devices not suitable for tests with traditional sources (e.g. cosmic rays or…

Instrumentation and Detectors · Physics 2020-04-06 Antonello Pellecchia , Antonio Ranieri , Piet Verwilligen

Cosmic ray muon has strong penetrating power and no ionizing radiation hazards, which makes it an ideal probe for detecting special nuclear materials. In this paper, a high spatial resolution muon tomography system based on Micromegas…

Instrumentation and Detectors · Physics 2022-02-16 Yu Wang , Zhiyong Zhang , Shubin Liu , Zhongtao Shen , Changqing Feng , Jianguo Liu , Yulin Liu

We describe here various detectors designs: GEM type, MICROMEGAStype, PPACtype as well as cascaded detectors made of a resistive mesh manufactured from a resistive Kapton foil, (20 microns thick, resistivity a few MOhm per square) by a…

Instrumentation and Detectors · Physics 2017-10-11 R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi

For its physics program with a high-intensity hadron beam of up to 2e7 particles/s, the COMPASS experiment at CERN requires tracking of charged particles scattered by very small angles with respect to the incident beam direction. While good…

The concept of a small, single-layer water Cherenkov detector, with three photomultiplier tubes (PMTs), placed at its bottom in a $120^{\circ}$ star configuration (\emph{Mercedes} Water Cherenkov Detector) is presented. The PMTs are placed…

We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber ({\mu}PIC) coupled with a field-programmable-gate-array-based data acquisition system. Our…

The aim of the presented work is the development of single-stage amplification resistive Micro Pattern Gas Detectors (MPGD) based on Micromegas technology with the following characteristics: ability to efficiently operate up to 10…

The paper summarizes our latest progress in the development of newly introduced micro pattern gaseous detectors with resistive electrodes. These resistive electrodes protect the detector and the front-end electronics in case of occasional…

Instrumentation and Detectors · Physics 2008-11-26 A. Di Mauro , B. Lund-Jensen , P. Martinengo , E. Nappi , R. Oliveira , V. Peskov , L. Periale , P. Picchi , F. Pietropaolo , I. Rodionov , J. C. Santiard

A novel photodetector based on a MCP-PMT vacuum tube with encapsulated CMOS ASIC has been tested at the CERN SPS high energy hadron beam, allowing single photon Cherenkov detection operating at 10$^4$ gain and with timing resolution of…

Micromegas is presently in use by many experiments providing enhanced performance when used in high particle environment. Compared with other solid-state detectors or conventional gas counters Micromegas is robust and radiation hard. Recent…

Instrumentation and Detectors · Physics 2008-11-26 I. Giomataris

The Antarctic Muon And Neutrino Detector Array (Amanda) is a high-energy neutrino telescope. It is a lattice of optical modules (OM) installed in the clear ice below the South Pole Station. Each OM contains a photomultiplier tube (PMT) that…

Astrophysics · Physics 2012-08-03 AMANDA Collaboration , M. Ackermann

The design of a detector based on MICROMEGAS (MICRO MEsh GAseous Structure) technology is presented. Our detector is characterized by a large active area of 398(\times)281 mm(^{2}), a pad read-out with 20(\times)22 mm(^{2}) segmentation,…

Instrumentation and Detectors · Physics 2016-08-15 L. Aphecetche , H. Delagrange , D. G. d'Enterria , M. Le Guay , X. Li , G. Martínez , M. J. Mora , P. Pichot , D. Roy , Y. Schutz

Large-scale optical neutrino and dark-matter detectors rely on large-area photomultiplier tubes (PMTs) for cost-effective light detection. The new R14688-100 8-inch PMT developed by Hamamatsu provides state-of-the-art timing resolution of…

Gas time projection chambers (TPCs) with Micromegas pixelated readouts are being used in dark matter searches and other rare event searches, due to their potential in terms of low background levels, energy and spatial resolution, gain, and…

A high spatial resolution tracking system was setup with the Micro-mesh gaseous structure (Micromegas) detectors in order to study the muon tomographic imaging technique for nuclear threat detection. 6 layers of 90 mm $\times$ 90 mm…

Instrumentation and Detectors · Physics 2022-09-12 Liu Cheng-Ming , Wen Qun-Gang , Zhang Zhi-Yong , Huang Guang-Shun

Muon imaging technology is an innovative imaging technique that can be applied in volcano imaging, heavy nuclear material detection, and archaeological research. The Micromegas detector is a promising choice for muon imaging due to its high…

Instrumentation and Detectors · Physics 2024-10-28 Ting Wang , Yu Wang , Zhihang Yao , Yulin Liu , Changqing Feng , Zhiyong Zhang , Shubin Liu

Micromegas detector is a gas detector with parallel plate structure, and it consists of a conversion gap in which radiations liberate ionization electrons and a thin amplification gap. The signal of the micromegas detector consists of two…

Instrumentation and Detectors · Physics 2018-06-19 Shuang. Zhou , Shengquan. Liu , Peng. Miao , Xinxin. Wang , Feng. Li , Ge. Jin , Zhilei. Zhang , Tianru. Geng

We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in…