English
Related papers

Related papers: HC$^3$L-Diff: Hybrid conditional latent diffusion …

200 papers

Cone-beam computed tomography (CBCT) is widely used for image-guided radiotherapy (IGRT). It provides real time visualization at low cost and dose. However, photon scattering and beam hindrance cause artifacts in CBCT. These include…

Medical Physics · Physics 2025-09-29 Alzahra Altalib , Chunhui Li , Alessandro Perelli

Cone-beam CT (CBCT) is routinely acquired during radiotherapy for patient setup, but its quantitative reliability is degraded by scatter, noise, and reconstruction artifacts, limiting Hounsfield Unit (HU) accuracy. We propose EPC-3D-Diff, a…

Computer Vision and Pattern Recognition · Computer Science 2026-05-21 Alzahra Altalib , Chunhui Li , Haytham Al Ewaidat , Khaled Alawneh , Ahmad Qendel , Alessandro Perelli

Background: Daily or weekly cone-beam computed tomography (CBCT) scans are commonly used for accurate patient positioning during the image-guided radiotherapy (IGRT) process, making it an ideal option for adaptive radiotherapy (ART)…

Objective: Cone-beam computed tomography (CBCT) provides a low-dose imaging alternative to conventional CT, but suffers from noise, scatter, and artifacts that degrade image quality. Synthetic CT (sCT) aims to translate CBCT to high-quality…

Medical Physics · Physics 2025-09-23 Alzahra Altalib , Chunhui Li , Alessandro Perelli

Cone-beam computed tomography (CBCT) images are problematic in clinical medicine because of their low contrast and high artifact content compared with conventional CT images. Although there are some studies to improve image quality, in…

Image and Video Processing · Electrical Eng. & Systems 2026-03-30 Naruki Murahashi , Mitsuhiro Nakamura , Megumi Nakao

Image compression under ultra-low bitrates remains challenging for both conventional learned image compression (LIC) and generative vector-quantized (VQ) modeling. Conventional LIC suffers from severe artifacts due to heavy quantization,…

Computer Vision and Pattern Recognition · Computer Science 2025-11-24 Lei Lu , Yize Li , Yanzhi Wang , Wei Wang , Wei Jiang

Diffusion models have significant impact on wide range of generative tasks, especially on image inpainting and restoration. Although the improvements on aiming for decreasing number of function evaluations (NFE), the iterative results are…

Image and Video Processing · Electrical Eng. & Systems 2024-11-20 Mahmut S. Gokmen , Jie Zhang , Ge Wang , Jin Chen , Cody Bumgardner

Low-dose computed tomography (LDCT) reduces radiation exposure but suffers from image artifacts and loss of detail due to quantum and electronic noise, potentially impacting diagnostic accuracy. Transformer combined with diffusion models…

Image and Video Processing · Electrical Eng. & Systems 2025-07-01 Qiqing Liu , Guoquan Wei , Zekun Zhou , Yiyang Wen , Liu Shi , Qiegen Liu

Non-contrast CT (NCCT) imaging may reduce image contrast and anatomical visibility, potentially increasing diagnostic uncertainty. In contrast, contrast-enhanced CT (CECT) facilitates the observation of regions of interest (ROI). Leading…

Image and Video Processing · Electrical Eng. & Systems 2024-11-18 Tingyi Lin , Pengju Lyu , Jie Zhang , Yuqing Wang , Cheng Wang , Jianjun Zhu

Cone Beam CT (CBCT) plays a crucial role in Adaptive Radiation Therapy (ART) by accurately providing radiation treatment when organ anatomy changes occur. However, CBCT images suffer from scatter noise and artifacts, making relying solely…

Image and Video Processing · Electrical Eng. & Systems 2023-08-08 Linjie Fu , Xia Li , Xiuding Cai , Dong Miao , Yu Yao , Yali Shen

In radiation therapy (RT), the reliance on pre-treatment computed tomography (CT) images encounter challenges due to anatomical changes, necessitating adaptive planning. Daily cone-beam CT (CBCT) imaging, pivotal for therapy adjustment,…

Computer Vision and Pattern Recognition · Computer Science 2024-09-20 Joonil Hwang , Sangjoon Park , NaHyeon Park , Seungryong Cho , Jin Sung Kim

Low dose computed tomography (LDCT) has attracted more and more attention in routine clinical diagnosis assessment, therapy planning, etc., which can reduce the dose of X-ray radiation to patients. However, the noise caused by low X-ray…

Image and Video Processing · Electrical Eng. & Systems 2021-07-06 Zhicheng Zhang , Lequan Yu , Xiaokun Liang , Wei Zhao , Lei Xing

Background: Cone-beam computed tomography (CBCT) scans, performed fractionally (e.g., daily or weekly), are widely utilized for patient alignment in the image-guided radiotherapy (IGRT) process, thereby making it a potential imaging…

Spectral computed tomography (CT) with photon-counting detectors holds immense potential for material discrimination and tissue characterization. However, under ultra-low-dose conditions, the sharply degraded signal-to-noise ratio (SNR) in…

Computer Vision and Pattern Recognition · Computer Science 2026-02-10 Peng Peng , Xinrui Zhang , Junlin Wang , Lei Li , Shaoyu Wang , Qiegen Liu

Computed Tomography (CT) scans are the standard-of-care for the visualization and diagnosis of many clinical ailments, and are needed for the treatment planning of external beam radiotherapy. Unfortunately, the availability of CT scanners…

Image and Video Processing · Electrical Eng. & Systems 2024-08-28 Yiran Sun , Hana Baroudi , Tucker Netherton , Laurence Court , Osama Mawlawi , Ashok Veeraraghavan , Guha Balakrishnan

While diffusion models have set a new benchmark for quality in Low-Dose Computed Tomography (LDCT) denoising, their clinical adoption is critically hindered by extreme computational costs, with inference times often exceeding thousands of…

Computer Vision and Pattern Recognition · Computer Science 2025-09-30 Tangtangfang Fang , Jingxi Hu , Xiangjian He , Jiaqi Yang

Computed tomography (CT) is one of the modalities for effective lung cancer screening, diagnosis, treatment, and prognosis. The features extracted from CT images are now used to quantify spatial and temporal variations in tumors. However,…

Image and Video Processing · Electrical Eng. & Systems 2023-03-28 Md Selim , Jie Zhang , Michael A. Brooks , Ge Wang , Jin Chen

Low-dose computed tomography (CT) images suffer from noise and artifacts due to photon starvation and electronic noise. Recently, some works have attempted to use diffusion models to address the over-smoothness and training instability…

Image and Video Processing · Electrical Eng. & Systems 2024-01-10 Qi Gao , Zilong Li , Junping Zhang , Yi Zhang , Hongming Shan

Limited-angle computed tomography (LACT) reconstruction is an inverse problem with severe ill-posedness arising from missing projection angles, and it is difficult to restore high-precision images without sufficient prior knowledge. In…

Image and Video Processing · Electrical Eng. & Systems 2026-03-06 Hinako Isogai , Naruki Murahashi , Mitsuhiro Nakamura , Megumi Nakao

By decomposing the image formation process into a sequential application of denoising autoencoders, diffusion models (DMs) achieve state-of-the-art synthesis results on image data and beyond. Additionally, their formulation allows for a…

Computer Vision and Pattern Recognition · Computer Science 2022-04-14 Robin Rombach , Andreas Blattmann , Dominik Lorenz , Patrick Esser , Björn Ommer
‹ Prev 1 2 3 10 Next ›