Related papers: Improved phase sensitivity of an SU(1,1) interfero…
To improve the phase sensitivity, multi-photon subtraction schemes within the SU(1,1) interferometer are proposed. The input states are the coherent state and the vacuum state, and the detection method is homodyne detection. The effects of…
By performing two local displacement operations (LDOs) inside an SU(1,1) interferometer, called as the displacement-assisted SU(1,1) [DSU(1,1)], both the phase sensitivity based on homodyne detection and quantum Fisher information (QFI)…
In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity…
We propose a theoretical scheme to improve the precision of phase measurement using intensity detection by implementing delocalized photon subtraction operation (D-PSO) inside the SU(1,1) interferometer, with the coherent state and the…
SU(1,1) interferometers, based on the usage of nonlinear elements, are superior to passive interferometers in phase sensitivity. However, the SU(1,1) interferometer cannot make full use of photons carrying phase information as the second…
Utilizing nonlinear elements, SU(1,1) interferometers demonstrate superior phase sensitivity compared to passive interferometers. However, the precision is significantly impacted by photon losses, particularly internal losses. We propose a…
We provide a general theoretical derivation of the phase sensitivity achieved by SU(1,1) interferometers under homodyne detection. The general expressions obtained accommodate arbitrary input states and include internal and external losses.…
Homodyne detection is often used for interferometers based on nonlinear optical gain media. For the configuration of a seeded, 'truncated SU(1,1)' interferometer Anderson et al. (Phys. Rev. A 95, 063843 (2017)) showed how to optimize the…
We propose a theoretical scheme to enhance the phase sensitivity by introducing a Kerr nonlinear phase shift into the traditional SU(1,1) interferometer with a coherent state input and homodyne detection. We investigate the realistic…
We study the phase sensitivity in the conventional $SU(2)$ and nonconventional $SU(1,1)$ interferometers with the coherent and squeezed vacuum input state via the quantum Cramer-Rao bound. We explicitly construct the detection scheme that…
Nonlinear SU(1,1) interferometers are fruitful and promising tools for spectral engineering and precise measurements with phase sensitivity below the classical bound. Such interferometers have been successfully realized in bulk and…
The success of quantum technologies is intimately connected to the possibility of using them in real-world applications. To this aim, we study the sensing capabilities of quantum SU(1,1) interferometers in the single-photon-pair regime and…
We theoretically study the phase sensitivity of the SU(1,1) interferometer with a coherent light together with a squeezed vacuum input case using the method of homodyne. We find that the homodyne detection has better sensitivity than the…
We consider an SU(1,1) interferometer employing four-wave mixers that is fed with two-mode states which are both coherent and intelligent states of the SU(1,1) Lie group. It is shown that the phase sensitivity of the interferometer can be…
We propose a novel method for enhancing phase estimation in the displacement-assisted SU(1,1) (DSU(1,1)) interferometer by incorporating the photon recycling technique, evaluated under single-intensity detection (SID) and homodyne detection…
We analyse a nonlinear interferometer, also known as an SU(1,1) interferometer, in the presence of internal losses and inefficient detectors. To overcome these limitations, we consider the effect of seeding one of the interferometer input…
Absolute sensitivity is measured for the phase measurement in an SU(1,1) type interferometer and the results are compared to that of a Mach-Zehnder interferometer operated under the condition of the same intra-interferometer intensity. The…
Nonlinear interferometers are promising tools for quantum metrology, as they are characterized by an improved phase sensitivity scaling compared to linear interferometers operating with classical light. However, the multimodeness of the…
An ${\rm SU(1,1)}$ interferometer uses a sequence of two optical parametric amplifiers for achieving sub-shot-noise sensitivity to a phase shift introduced in between. We present the first realization of a wide-field ${\rm SU(1,1)}$…
The SU(1,1) interferometer can be thought of as a Mach-Zehnder interferometer with its linear beamsplitters replaced with parametric nonlinear optical processes. We consider the cases of bright and vacuum-seeded SU(1,1) interferometers…