Related papers: FPGA-based digitizer for BGO-based time-of-flight …
Intraoperative Gamma Probe (IPG) remains the current gold standard modality for sentinel lymph node identification and tumor removal in cancer patients. However, even alongside the optical dyes they do not meet with <5% false negative rates…
Long-distance depth imaging holds great promise for applications such as autonomous driving and robotics. Direct time-of-flight (dToF) imaging offers high-precision, long-distance depth sensing, yet demands ultra-short pulse light sources…
Small animal Positron Emission Tomography (PET) is dedicated to small animal imaging, which requires high position and energy precision, as well as good flexibility and efficiency of the electronics. This paper presents the design of a…
Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified…
Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…
A novel detector based on a polycrystalline diamond sensor is here employed in an advanced Time-Of-Flight scheme for the characterization of energetic ions accelerated during laser-matter interactions. The optimization of the detector and…
We present a Time-to-Digital Converter (TDC) implemented on a 16 nm Xilinx UltraScale Plus FPGA that achieves a resolution of 1.15 ps, RMS precision of 3.38 ps, a differential nonlinearity (DNL) of [-0.43, 0.24] LSB, and an integral…
The TRIDENT (Tropical Deep-sea Neutrino Telescope) experiment is a next-generation underwater neutrino observatory planned for deployment in the West Pacific Ocean, designed to detect astrophysical neutrinos through Cherenkov radiation. The…
The barrel time-of-flight (TOF) detector for the PANDA experiment at FAIR in Darmstadt is planned as a scintillator tile hodoscope (SciTil) using 8000 small scintillator tiles. It will provide fast event timing for a software trigger in the…
Transparent conducting oxides (TCO) such as indium-tin-oxide (ITO) exhibit strong optical nonlinearity in the frequency range where their permittivities are near zero. We leverage this nonlinear optical response to realize a sub-picosecond…
A readout electronic with high time and energy resolution performance is designed for the SDD (Silicon Drift Detector) signals readout, which is aimed for X-ray pulsar based navigation (XNAV). For time measurement, the input signal is fed…
Single-photon time-of-flight (TOF) non-line-of-sight (NLOS) imaging enables the high-resolution reconstruction of objects outside the field of view. The compactness of TOF NLOS imaging systems, entailing the miniaturization of key…
We describe here an efficient machine-learning based approach for the optimization of parameters used for extracting the arrival time of waveforms, in particular those generated by the detection of 511 keV annihilation gamma-rays by a 60…
We introduce pulsed correlation time-of-flight (PC-ToF) sensing, a new operation mode for correlation time-of-flight range sensors that combines a sub-nanosecond laser pulse source with a rectangular demodulation at the sensor side. In…
Inspired by Wilkinson ADC method, we implement a fast linear discharge method based on FPGA to digitize nuclear pulse signal. In this scheme, we use a constant current source to discharge the charge on capacitor which is integrated by the…
We constructed a new time-of-flight (TOF) detector consisting of resistive plate chambers (RPCs) to measure particle energy in the BGOegg experiment. The BGOegg-RPC has a unique feature which enables us to cover a large area with a small…
Time-bin encoded photon pairs enable robust, decoherence-resistant transmission through optical fibers for long-distance quantum communication, where phase noise poses a critical limitation to stable operation. Here, we implement an…
Small animal Positron Emission Tomography (PET) is dedicated to small animal imaging. Animals used in experiments, such as rats and monkeys, are often much smaller than human bodies, which requires higher position and energy precision of…
This paper describes the data acquisition and trigger system of the Thin Time-of-flight PET (TT-PET) scanner. The system is designed to read out in the order of 1000 pixel sensors used in the scanner and to provide a reference timing signal…
Here we describe an advanced multi functional, variable-energy positron beam system capable of measuring the energies of multiple positron-induced electrons in coincidence with the Doppler-shifted gamma photon resulting from the…