English
Related papers

Related papers: FPGA-based digitizer for BGO-based time-of-flight …

200 papers

A prototype of DIRC-like Time-of-Flight detector (DTOF), including a pico-second time measurement electronics, is developed and tested preliminarily. The basic structure of DTOF is composed of a fused silica radiator connected to fast…

Instrumentation and Detectors · Physics 2018-06-08 Qiang Cao , Xin Li , Liwei Wang , Jie Kuang , Yonggang Wang , Cheng Li

Bismuth germanate (BGO) is gaining renewed attention as a viable material for hybrid Cherenkov/scintillation time-of-flight positron emission tomography (TOF-PET) detectors. While single-crystal studies have demonstrated excellent timing…

Instrumentation and Detectors · Physics 2025-11-27 Minseok Yi , Daehee Lee , Alberto Gola , Stefano Merzi , Michele Penna , Simon R. Cherry , Jae Sung Lee , Sun Il Kwon

Positron emission tomography (PET) is the most sensitive biomedical imaging modality for non-invasively detecting and visualizing positron-emitting radiopharmaceuticals within a subject. In PET, measuring the time-of-flight (TOF)…

Instrumentation and Detectors · Physics 2024-10-17 Minseok Yi , Daehee Lee , Alberto Gola , Stefano Merzi , Michele Penna , Jae Sung Lee , Simon R. Cherry , Sun Il Kwon

Fully Field Programmable Gate Array (FPGA)based digitizer for high-resolution time and energy measurement is an attractive low cost solution for the readout electronics in positron emission computed tomography (PET)detector. In recent…

Instrumentation and Detectors · Physics 2022-01-07 Cong Ma , Wubin Wang , Xiaokun Zhao , Li Yu , Guocheng Wu

Time measurement plays a crucial rule for the purpose of particle identification in high energy physical experiments. With the upgrading of physical goal and the developing of electronics, modern time measurement system meets the…

Instrumentation and Detectors · Physics 2015-12-09 Huanhuan Fan , Ping Cao , Shubin Liu , Qi An

Time-of-flight measurement is an important advancement in PET scanners to improve image reconstruction with a lower delivered radiation dose. This article describes the monolithic ASIC for the TT-PET project, a novel idea for a…

Modeling the timing performance of light-based radiation detectors accurately is essential for optimizing time-of-flight positron emission tomography (TOF-PET). We present an analytic framework that combines existing models to predict the…

Instrumentation and Detectors · Physics 2025-10-08 Nicolaus Kratochwil , Emilie Roncali , Gerard Arino-Estrada

In order to reconstruct gamma-gamma physics events tagged with High Energy Tagger (HET) in the KLOE-2 (K LOng Experiment 2), we need to measure the Time Of Flight (TOF) of the electrons and positrons from the KLOE-2 Interaction Point (IP)…

Instrumentation and Detectors · Physics 2015-06-05 L. Iafolla , A. Balla , M. Beretta , P. Ciambrone , M. Gatta , F. Gonnella , M. Mascolo , R. Messi , D. Moricciani , D. Riondino

For TOF positron emission tomography (TOF PET) detectors, time-to-digital converters (TDCs) are essential to resolve the coincidence time of the photon pairs. Recently, an efficient TDC structure called ring-oscillator-based (RO-based)…

Instrumentation and Detectors · Physics 2017-06-12 Ke Cui , Xiangyu Li , Zongkai Liu , Rihong Zhu

Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing…

Instrumentation and Detectors · Physics 2016-04-19 J. W. Zhao , B. H. Sun , I. Tanihata , S. Terashima , L. H. Zhu , A. Enomoto , D. Nagae , T. Nishimura , S. Omika , A. Ozawa , Y. Takeuchi , T. Yamaguchi

The purpose of this study was to show how advanced concepts of compact, lossless and "Time Of Flight" (TOF) capable electronics similar to those foreseen for the LHC and ILC experiments could be fairly and easily transferred to the medical…

Instrumentation and Detectors · Physics 2009-08-03 P. -E. Vert , J. Lecoq , G. Montarou , N. Pauna , B. Joly , M. Boutemeur , H. Mathez , R. Gaglione , P. Le Dû

The aim of this work is to show the potential capabilities of monolithic crystals coupled to large SiPM arrays, to be considered as detector blocks for PET scanners enabling Time Of Flight (TOF) capabilities. Monolithic blocks allow one to…

Time to Digital Converters (TDCs) are very common devices in particles physics experiments. A lot of "off-the-shelf" TDCs can be employed but the necessity of a custom DAta acQuisition (DAQ) system makes the TDCs implemented on the…

Instrumentation and Detectors · Physics 2020-09-07 A. Balla , M. Beretta , P. Ciambrone , M. Gatta , F. Gonnella , L. Iafolla , M. Mascolo , R. Messi , D. Moricciani , D. Riondino

Time-tagging units and coincidence detectors are used in many scientific research fields. The required timing resolution and number of input channels are varying, but some emerging experiments in the field of quantum optics require up to 32…

Instrumentation and Detectors · Physics 2020-11-03 Attila Hidvegi

In this paper we prove that the choice of a suitable treatment of the scintillator surfaces, along with suitable photodetectors electronics and specific algorithms for raw data analysis, allow to achieve an optimal tradeoff between energy,…

Medical Physics · Physics 2012-03-02 Luigi Cosentino , Paolo Finocchiaro , Alfio Pappalardo , Franco Garibaldi

Time-of-Flight Positron Emission Tomography is a medical imaging technique, based on the detection of two back-to-back {\gamma}-photons generated from radiotracers injected in the body. Its limit is the ability of employed scintillation…

Measurement of the Time-of-Flight (TOF) of the 511 keV gammas brings an important reduction of statistical noise in the PET image, with higher precision time measurements producing clearer images. Scintillating crystals are used to convert…

Instrumentation and Detectors · Physics 2019-12-03 K. Doroud , Z. Liu , M. C. S. Williams

Time-of-flight (ToF) measurements is a possible alternative to anti-scatter grids in computed tomography (CT). Simulations have shown a possible 75% reduction in the detrimental scattering contribution with a 100 ps FWHM timing resolution.…

Time-of-flight (tof) techniques are standard techniques in high energy physics to determine particles propagation directions. Since particles velocities are generally close to c, the speed of light, and detectors typical dimensions at the…

Instrumentation and Detectors · Physics 2014-02-11 J. Marteau , J. De Bremond D'ars , D. Gibert , K. Jourde , S. Gardien , C. Girerd , J. -C. Ianigro

In this work, we report on the timing performances of the Time-Of-Flight (TOF) apparatus of the FRACAS large acceptance mass spectrometer designed to measure the fragmentation cross sections of a $^{12}$C beam in hadrontherapy. The TOF…

Instrumentation and Detectors · Physics 2020-02-13 S. Salvador , E. Barlerin , J. Perronnel , C. Vandamme
‹ Prev 1 2 3 10 Next ›