Related papers: Cold Beam Optical Clock with Multifrequency Spectr…
Arm-locking is a technique for stabilizing the frequency of a laser in an inter-spacecraft interferometer by using the spacecraft separation as the frequency reference. A candidate technique for future space-based gravitational wave…
We experimentally demonstrate thermo-optic locking of a semiconductor laser to an integrated toroidal optical microresonator. The lock is maintained for time periods exceeding twelve hours, without requiring any electronic control systems.…
We have investigated the benefits of spin squeezed states for clocks operated with typical Brownian frequency noise-limited laser sources. Based on an analytic model of the closed servo-loop of an optical atomic clock, we can give…
A low noise laser system for atom interferometry is realized with phase-locked fiber lasers, where the performance of the OPLL is greatly enhanced by the FEOM feedback loop and the narrow linewidths. The laser system demonstrated contribute…
We present a cold atom gravimeter operating with a sample of Bose-condensed Rubidium-87 atoms. Using a Mach-Zehnder configuration with the two arms separated by a two-photon Bragg transition, we observe interference fringes with a…
We implement dynamic control of a superradiant, cold atom $^{87}$Rb Raman laser to realize the equivalent of conditional Ramsey spectroscopy for sensing atomic phase shifts. Our method uses the non-demolition mapping of the collective…
A simple scheme for all-optical time interpolation using spectral interferometry is put forward that is in principle capable of single-shot measurements. In this method, the arrival time of optical timing pulses is encoded into the spectrum…
Cold plasma of power 13W has been applied on step index plastic optical fibers. It is used to study the ability for any variations in the optical parameters that are effective in communication. The effect of plasma on the optical…
We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique (PPOP) in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT…
The differential polarizability, due to near-infrared light at 1126 nm, of the 27Al+ 1S0 -> 3P0 clock transition is measured to be 4\pi\epsilon_0 x (1.6 +/- 0.5) x 10^{-31} m^3. This measurement is combined with experimental oscillator…
We report a theoretical study of a double-well Ramsey interferometer using internal state labelling. We consider the use of a thermal ensemble of cold atoms rather than a Bose-Einstein condensate to minimize the effects of atomic…
We have constructed an optical clock with a fractional frequency inaccuracy of 8.6e-18, based on quantum logic spectroscopy of an Al+ ion. A simultaneously trapped Mg+ ion serves to sympathetically laser-cool the Al+ ion and detect its…
A compact and robust laser system, based on a frequency-doubled telecom laser, providing all the lasers needed for a rubidium cold atom interferometer using optical lattices is presented. Thanks to an optical switch at 1.5 \mu m and a…
We report on an evaluation of an optical clock that uses the $\phantom{}^2S_{1/2} \rightarrow \phantom{}^2D_{5/2}$ transition of a single $^{88}$Sr$^+$ ion as the reference. In contrast to previous work, we estimate the effective…
A cold atomic gas with an inverted population on a transition coupled to a field mode of an optical resonator constitutes a generic model of a laser. For quasi-continuous operation, external pumping, trapping and cooling of the atoms is…
Optical interferometers increasingly use single-mode fibers as spatial filters to convert varying wavefront distortion into intensity fluctuations which can be monitored for accurate calibration of fringe amplitudes. Here I propose using an…
We investigate Ramsey spectroscopy performed on a synchronized ensemble of two-level atoms. The synchronization is induced by the collective coupling of the atoms to a heavily damped mode of an optical cavity. We show that, in principle,…
In this article, we present a deflection measurement setup for Atomic Force Microscopy (AFM). It is based on a quadrature phase differential interferometer: we measure the optical path difference between a laser beam reflecting above the…
Interferometry, as the key technique in modern precision measurements, has been used for length diagnosis in the fields of engineering metrology and astronomy. Analogous interferometric technique for time domain precision measurement is a…
We report frequency measurement of the clock transition in an 115In+ ion sympathetically-cooled with Ca+ ions in a linear rf trap. The Ca+ ions are used as a probe of the external electromagnetic field and as the coolant for preparing the…