Related papers: Noise-aware Dynamic Image Denoising and Positron R…
Positron emission tomography (PET) is a critical tool for diagnosing tumors and neurological disorders but poses radiation risks to patients, particularly to sensitive populations. While reducing injected radiation dose mitigates this risk,…
Medical imaging modalities including magnetic resonance imaging (MRI), computed tomography (CT), and ultrasound are essential for accurate diagnosis and treatment planning in modern healthcare. However, noise contamination during image…
Deep learning-based image denoising approaches have been extensively studied in recent years, prevailing in many public benchmark datasets. However, the stat-of-the-art networks are computationally too expensive to be directly applied on…
Inverse Synthetic Aperture Radar (ISAR) imaging presents a formidable challenge when it comes to small everyday objects due to their limited Radar Cross-Section (RCS) and the inherent resolution constraints of radar systems. Existing ISAR…
Deep spectral methods reframe the image decomposition process as a graph partitioning task by extracting features using self-supervised learning and utilizing the Laplacian of the affinity matrix to obtain eigensegments. However, instance…
Consumer-level depth cameras and depth sensors embedded in mobile devices enable numerous applications, such as AR games and face identification. However, the quality of the captured depth is sometimes insufficient for 3D reconstruction,…
Four-dimensional (4D) wide coverage computed tomography (CT) is an effective imaging modality for measuring the mechanical function of the myocardium. However, repeated CT measurement across several heartbeats is still a concern. A…
Reconstructing images using Computed Tomography (CT) in an industrial context leads to specific challenges that differ from those encountered in other areas, such as clinical CT. Indeed, non-destructive testing with industrial CT will often…
A joint image reconstruction and segmentation approach based on disentangled representation learning was trained to enable cardiac cine MR imaging in real-time and under free-breathing. An exploratory feasibility study tested the proposed…
Deep learning (DL) has shown promise for faster, high quality accelerated MRI reconstruction. However, supervised DL methods depend on extensive amounts of fully-sampled (labeled) data and are sensitive to out-of-distribution (OOD) shifts,…
Noise is an important factor that degrades the quality of medical images. Impulse noise is a common noise, which is caused by malfunctioning of sensor elements or errors in the transmission of images. In medical images due to presence of…
Endoscopes featuring a miniaturized design have significantly enhanced operational flexibility, portability, and diagnostic capability while substantially reducing the invasiveness of medical procedures. Recently, single-use endoscopes…
Fluorescence microscopy is a key driver to promote discoveries of biomedical research. However, with the limitation of microscope hardware and characteristics of the observed samples, the fluorescence microscopy images are susceptible to…
Medical image denoising (MID) lacks absolutely clean images for supervision, leading to a noisy reference problem that fundamentally limits denoising performance. Existing simulated-supervised discriminative learning (SimSDL) and…
Noise modeling and reduction are fundamental tasks in low-level computer vision. They are particularly important for smartphone cameras relying on small sensors that exhibit visually noticeable noise. There has recently been renewed…
Magnetic Resonance Imaging (MRI), including diffusion MRI (dMRI), serves as a ``microscope'' for anatomical structures and routinely mitigates the influence of low signal-to-noise ratio scans by compromising temporal or spatial resolution.…
Variability of IVIM parameters throughout the literature is a long-standing issue, and perfusion-related parameters are difficult to interpret. We demonstrate for improving the analysis of intravoxel incoherent motion imaging (IVIM)…
Dynamic imaging involves the reconstruction of a spatio-temporal object at all times using its undersampled measurements. In particular, in dynamic computed tomography (dCT), only a single projection at one view angle is available at a…
Image reconstruction in low-count PET is particularly challenging because gammas from natural radioactivity in Lu-based crystals cause high random fractions that lower the measurement signal-to-noise-ratio (SNR). In model-based image…
Neural scene representations, such as Neural Radiance Fields (NeRF), are based on training a multilayer perceptron (MLP) using a set of color images with known poses. An increasing number of devices now produce RGB-D(color + depth)…