Related papers: OpenDosimeter: Open Hardware Personal X-ray Dosime…
Understanding objects through multiple sensory modalities is fundamental to human perception, enabling cross-sensory integration and richer comprehension. For AI and robotic systems to replicate this ability, access to diverse, high-quality…
Photoplethysmography is a prevalent, non-invasive heart monitoring method. In this paper an implementation of photoplethysmography on the Raspberry Pi is presented. Two modulation techniques are discussed, which make possible to measure…
Purpose: To develop and evaluate DosimeTron, an agentic AI system for automated patient-specific MC internal radiation dosimetry in PET/CT examinations. Materials and Methods: In this retrospective study, DosimeTron was evaluated on a…
Fiber dosimeters have recently drawn much interest for measuring in vivo and in real time the dose of medical radiations. This paper presents the first miniaturized fiber dosimeter integrated at the end of a narrow 125-micron outer diameter…
In the early stages of semiconductor equipment development, obtaining large quantities of raw optical images poses a significant challenge. This data scarcity hinder the advancement of AI-powered solutions in semiconductor manufacturing. To…
Purpose: A diode EDGE Detector with a newly designed electrometer has been characterized for use in an UHDR electron beam and demonstrated appropriateness for UHDR FLASH radiotherapy dosimetry. Methods: Dose linearity, mean dose rate, and…
Peripheral blood oxygen saturation Sp02 is a vital measure in healthcare. Modern off-the-shelf wrist-worn devices, such as the Apple Watch, FitBit, and Samsung Gear, have an onboard sensor called a pulse oximeter. While pulse oximeters are…
The increasing interest in FLASH-RT has lead to the conversion of linear accelerators to enable ultra-high dose rate (UHDR) beams for preclinical research. Dosimetry hereof remains challenging with several crucial aspects missing. This work…
Charged Particle Therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbons. A critical issue is the monitoring of the dose released by the beam to the tumor and to the surrounding tissues. We present…
Closed-loop brain stimulation holds potential as personalized treatment for drug-resistant epilepsy (DRE) but still suffers from limitations that result in highly variable efficacy. First, stimulation is typically delivered upon detection…
High-time-resolution counters based on plastic scintillator with silicon photomultiplier (SiPM) readout have been developed for applications to high energy physics experiments for which relatively large-sized counters are required. We have…
We introduce a cost-efficient, and open-source measurement system for measuring and monitoring indoor air quality, aerosol concentration, dust contamination, and comfort-relevant quantities. The system allows to access these quantities…
In the context of particle therapy monitoring, we are developing a gamma-ray detector to determine the ion range in vivo from the measurement of particle time-of-flight. For this application, a beam monitor capable to tag in time the…
NMR spectroscopy is an excellent tool for monitoring in-situ chemical reactions. In particular, DOSY measurement is well suited to characterize transient species by the determination of their sizes. However, here we bring to light a…
The advent of microcontrollers with enough CPU power and with analog and digital peripherals makes possible to design a complete particle detector with relative acquisition system around one microcontroller chip. The existence of a world…
Scintillating homogeneous detectors represent the state of the art in electromagnetic calorimetry. Moreover, the currently neglected crystalline nature of the most common inorganic scintillators can be exploited to achieve an outstanding…
Balloon- and space-borne cosmic-ray experiments employ plastic scintillators read out by silicon photomultipliers (SiPMs) to achieve picosecond-level time resolutions for triggering and particle identification. The performance of these…
X-ray polarization measurement of cosmic sources provides two unique parameters namely degree and angle of polarization which can probe the emission mechanism and geometry at close vicinity of the compact objects. Specifically, the hard…
In 2016, an exposure meter was installed on the Lijiang Fiber-fed High-Resolution Spectrograph to monitor the coupling of starlight to the science fiber during observations. Based on it, we investigated a method to estimate the exposure…
Energy measurement of computer devices, which are widely used in the Internet of Things (IoT), is an important yet challenging task. Most of these IoT devices lack ready-to-use hardware or software for power measurement. In this paper, we…