English
Related papers

Related papers: Joint image reconstruction and segmentation of rea…

200 papers

ECG-gated cine imaging in breath-hold enables high-quality diagnostics in most patients, arrhythmia and inability to hold breath, however, can severely corrupt outcomes. Real-time cardiac MRI in free-breathing leverages robust and faster…

Background: Conventional cardiovascular magnetic resonance (CMR) in paediatric and congenital heart disease uses 2D, breath-hold, balanced steady state free precession (bSSFP) cine imaging for assessment of function and cardiac-gated,…

Image and Video Processing · Electrical Eng. & Systems 2025-07-01 Mark Wrobel , Michele Pascale , Tina Yao , Ruaraidh Campbell , Elena Milano , Michael Quail , Jennifer Steeden , Vivek Muthurangu

Cine cardiac magnetic resonance (CMR) imaging is considered the gold standard for cardiac function evaluation. However, cine CMR acquisition is inherently slow and in recent decades considerable effort has been put into accelerating scan…

Real-time cardiac cine MRI does not require ECG gating in the data acquisition and is more useful for patients who can not hold their breaths or have abnormal heart rhythms. However, to achieve fast image acquisition, real-time cine…

Image and Video Processing · Electrical Eng. & Systems 2020-08-21 Eric Z. Chen , Xiao Chen , Jingyuan Lyu , Yuan Zheng , Terrence Chen , Jian Xu , Shanhui Sun

Accelerating the acquisition of magnetic resonance imaging (MRI) is a challenging problem, and many works have been proposed to reconstruct images from undersampled k-space data. However, if the main purpose is to extract certain…

Image and Video Processing · Electrical Eng. & Systems 2019-08-22 Chen Qin , Wenjia Bai , Jo Schlemper , Steffen E. Petersen , Stefan K. Piechnik , Stefan Neubauer , Daniel Rueckert

Cine cardiac MRI is routinely acquired for the assessment of cardiac health, but the imaging process is slow and typically requires several breath-holds to acquire sufficient k-space profiles to ensure good image quality. Several…

To develop an efficient motion-compensated reconstruction technique for free-breathing cardiac magnetic resonance imaging (MRI) that allows high-quality images to be reconstructed from multiple undersampled single-shot acquisitions. The…

Computer Vision and Pattern Recognition · Computer Science 2016-11-16 Aurelien Bustin , Anne Menini , Martin A. Janich , Darius Burschka , Jacques Felblinger , Anja C. S. Brau , Freddy Odille

Conventional cardiac cine MRI methods rely on retrospective gating, which limits temporal resolution and the ability to capture continuous cardiac dynamics, particularly in patients with arrhythmias and beat-to-beat variations. To address…

Image and Video Processing · Electrical Eng. & Systems 2024-12-18 Wenqi Huang , Veronika Spieker , Siying Xu , Gastao Cruz , Claudia Prieto , Julia Schnabel , Kerstin Hammernik , Thomas Kuestner , Daniel Rueckert

Recent advances in deep learning based image segmentation methods have enabled real-time performance with human-level accuracy. However, occasionally even the best method fails due to low image quality, artifacts or unexpected behaviour of…

In this work, we propose a novel image reconstruction framework that directly learns a neural implicit representation in k-space for ECG-triggered non-Cartesian Cardiac Magnetic Resonance Imaging (CMR). While existing methods bin acquired…

Image and Video Processing · Electrical Eng. & Systems 2023-06-21 Wenqi Huang , Hongwei Li , Jiazhen Pan , Gastao Cruz , Daniel Rueckert , Kerstin Hammernik

Respiratory motion can cause strong blurring artifacts in the reconstructed image during MR acquisition. These artifacts become more prominent when use in the presence of undersampled data. Recently, compressed sensing (CS) is developed as…

Image and Video Processing · Electrical Eng. & Systems 2019-04-10 Abdul Haseeb Ahmed , Ijaz M. Qureshi , Jawad Ali Shah , Hammad Omer

Cardiovascular magnetic resonance (CMR) imaging is the gold standard for diagnosing several heart diseases due to its non-invasive nature and proper contrast. MR imaging is time-consuming because of signal acquisition and image formation…

Image and Video Processing · Electrical Eng. & Systems 2025-04-29 Kian Anvari Hamedani , Narges Razizadeh , Shahabedin Nabavi , Mohsen Ebrahimi Moghaddam

Diffusion Tensor Cardiac Magnetic Resonance (DT-CMR) enables us to probe the microstructural arrangement of cardiomyocytes within the myocardium in vivo and non-invasively, which no other imaging modality allows. This innovative technology…

Image and Video Processing · Electrical Eng. & Systems 2022-06-22 Michael Tanzer , Pedro Ferreira , Andrew Scott , Zohya Khalique , Maria Dwornik , Dudley Pennell , Guang Yang , Daniel Rueckert , Sonia Nielles-Vallespin

Conventional cardiac cine MRI relies on breath-hold Cartesian acquisitions, which are vulnerable to motion artifacts and can be uncomfortable or infeasible, particularly for pediatric and other noncompliant patients who cannot reliably hold…

Image and Video Processing · Electrical Eng. & Systems 2026-05-21 Mahmut Yurt , Kanghyun Ryu , Zhitao Li , Xucheng Zhu , Xianglun Mao , Martin Janich , Marcus Alley , Kawin Setsompop , John Pauly , Shreyas Vasanawala , Ali Syed

Cardiac magnetic resonance imaging (MRI) requires reconstructing a real-time video of a beating heart from continuous highly under-sampled measurements. This task is challenging since the object to be reconstructed (the heart) is…

Image and Video Processing · Electrical Eng. & Systems 2024-01-12 Johannes F. Kunz , Stefan Ruschke , Reinhard Heckel

Segmenting anatomical structures in medical images has been successfully addressed with deep learning methods for a range of applications. However, this success is heavily dependent on the quality of the image that is being segmented. A…

Image and Video Processing · Electrical Eng. & Systems 2020-07-06 Ilkay Oksuz , James R. Clough , Bram Ruijsink , Esther Puyol Anton , Aurelien Bustin , Gastao Cruz , Claudia Prieto , Andrew P. King , Julia A. Schnabel

In real-time (RT) cardiac cine imaging, a stack of 2D slices is collected sequentially under free-breathing conditions. A complete heartbeat from each slice is then used for cardiac function quantification. The inter-slice respiratory…

Image and Video Processing · Electrical Eng. & Systems 2020-07-10 Chong Chen , Yingmin Liu , Orlando P. Simonetti , Rizwan Ahmad

Purpose: To introduce a novel deep learning based approach for fast and high-quality dynamic multi-coil MR reconstruction by learning a complementary time-frequency domain network that exploits spatio-temporal correlations simultaneously…

Image and Video Processing · Electrical Eng. & Systems 2021-06-21 Chen Qin , Jinming Duan , Kerstin Hammernik , Jo Schlemper , Thomas Küstner , René Botnar , Claudia Prieto , Anthony N. Price , Joseph V. Hajnal , Daniel Rueckert

In cardiac magnetic resonance (CMR) imaging, a 3D high-resolution segmentation of the heart is essential for detailed description of its anatomical structures. However, due to the limit of acquisition duration and respiratory/cardiac…

Image and Video Processing · Electrical Eng. & Systems 2021-07-09 Shuo Wang , Chen Qin , Nicolo Savioli , Chen Chen , Declan O'Regan , Stuart Cook , Yike Guo , Daniel Rueckert , Wenjia Bai

The quality of cardiac magnetic resonance (CMR) imaging is susceptible to respiratory motion artifacts. The model robustness of automated segmentation techniques in face of real-world respiratory motion artifacts is unclear. This manuscript…

Image and Video Processing · Electrical Eng. & Systems 2022-10-13 Shuo Wang , Chen Qin , Chengyan Wang , Kang Wang , Haoran Wang , Chen Chen , Cheng Ouyang , Xutong Kuang , Chengliang Dai , Yuanhan Mo , Zhang Shi , Chenchen Dai , Xinrong Chen , He Wang , Wenjia Bai
‹ Prev 1 2 3 10 Next ›