English
Related papers

Related papers: CT scans without X-rays: parallel-beam imaging fro…

200 papers

Electrical Impedance Tomography (EIT) provides a non-invasive, portable imaging modality with significant potential in medical and industrial applications. Despite its advantages, EIT encounters two primary challenges: the ill-posed nature…

Image and Video Processing · Electrical Eng. & Systems 2025-04-29 Chuyu Wang , Huiting Deng , Dong Liu

Electrical impedance tomography (EIT) is a non-invasive imaging method with diverse applications, including medical imaging and non-destructive testing. The inverse problem of reconstructing internal electrical conductivity from boundary…

Image and Video Processing · Electrical Eng. & Systems 2025-07-08 Sara Sippola , Siiri Rautio , Andreas Hauptmann , Takanori Ide , Samuli Siltanen

Electrical impedance tomography (EIT) is highly affected by modeling errors regarding electrode positions and the shape of the imaging domain. In this work, we propose a new inclusion detection technique that is completely independent of…

Analysis of PDEs · Mathematics 2018-10-11 Bastian Harrach , Eunjung Lee , Marcel Ullrich

Electrical impedance tomography (EIT) plays a crucial role in non-invasive imaging, with both medical and industrial applications. In this paper, we present three data-driven reconstruction methods for EIT imaging. These three approaches…

Image and Video Processing · Electrical Eng. & Systems 2024-07-03 Alexander Denker , Zeljko Kereta , Imraj Singh , Tom Freudenberg , Tobias Kluth , Peter Maass , Simon Arridge

Two reconstruction methods of Electrical Impedance Tomography (EIT) are numerically compared for nonsmooth conductivities in the plane based on the use of complex geometrical optics (CGO) solutions to D-bar equations involving the global…

Analysis of PDEs · Mathematics 2015-06-17 Kari Astala , Lassi Päivärinta , Juan Manuel Reyes , Samuli Siltanen

Electrical Impedance Tomography (EIT) is a non-invasive imaging technique that reconstructs conductivity distributions within a body from boundary measurements. However, EIT reconstruction is hindered by its ill-posed nonlinear inverse…

Image and Video Processing · Electrical Eng. & Systems 2024-09-11 Bowen Tong , Junwu Wang , Dong Liu

Electrical Impedance Tomography (EIT) systems are becoming popular because they present several advantages over competing systems. However, EIT leads to images with very low resolution. Moreover, the nonuniform sampling characteristic of…

Computer Vision and Pattern Recognition · Computer Science 2019-05-01 Ricardo A. Borsoi , Julio C. C. Aya , Guilherme H. Costa , José C. M. Bermudez

In Electrical Impedance Tomography (EIT), the internal conductivity of a body is recovered via current and voltage measurements taken at its surface. The reconstruction task is a highly ill-posed nonlinear inverse problem, which is very…

Numerical Analysis · Mathematics 2018-03-28 Sarah Hamilton , Andreas Hauptmann , Samuli Siltanen

Objective: Inclusion of individualised electrical conductivities of head tissues is crucial for the accuracy of electrical source imaging techniques based on electro/magnetoencephalography and the efficacy of transcranial electrical…

Objective: The strengths of Electrical Impedance Tomography (EIT) are its capability of imaging the internal body by using a noninvasive, radiation safe technique, and the absence of known hazards. In this paper we introduce a novel idea of…

Signal Processing · Electrical Eng. & Systems 2022-03-08 Sebastien Martin

In a standard computed tomography (CT) image, pixels having the same Hounsfield Units (HU) can correspond to different materials and it is therefore challenging to differentiate and quantify materials. Dual-energy CT (DECT) is desirable to…

Medical Physics · Physics 2020-10-27 Wei Zhao , Tianling Lyu , Yang Chen , Lei Xing

This paper presents a multi-resolution reconstruction method for Electrical Impedance Tomography (EIT), referred to as MR-EIT, which is capable of operating in both supervised and unsupervised learning modes. MR-EIT integrates an ordered…

Computer Vision and Pattern Recognition · Computer Science 2025-03-04 Fangming Shi , Jinzhen Liu , Xiangqian Meng , Yapeng Zhou , Hui Xiong

Electrical Impedance Tomography (EIT) aims to recover the internal conductivity and permittivity distributions of a body from electrical measurements taken on electrodes on the surface of the body. The reconstruction task is a severely…

Numerical Analysis · Mathematics 2016-05-25 Sarah Jane Hamilton , Jennifer L. Mueller , Melody Alsaker

Electrical Impedance Tomography (EIT) is a non-invasive medical imaging method that reconstructs electrical conductivity mediums from boundary voltage-current measurements, but its severe ill-posedness renders direct operator learning with…

Numerical Analysis · Mathematics 2026-01-14 Amit Bhat , Ke Chen , Chunmei Wang

Electrical impedance tomography (EIT) is a noninvasive imaging method whereby electrical measurements on the boundary of a conductive medium (the data) are taken according to a prescribed protocol set and inverted to map the internal…

This paper introduces a new approach for solving electrical impedance tomography (EIT) problems using deep neural networks. The mathematical problem of EIT is to invert the electrical conductivity from the Dirichlet-to-Neumann (DtN) map.…

Computational Physics · Physics 2020-01-29 Yuwei Fan , Lexing Ying

Radon Transformation is generally used to construct optical image (like CT image) from the projection data in biomedical imaging. In this paper, the concept of Radon Transformation is implemented to reconstruct Electrical Impedance…

Computer Vision and Pattern Recognition · Computer Science 2012-11-07 Md. Ali Hossain , Ahsan-Ul-Ambia , Md. Aktaruzzaman , Md. Ahaduzzaman Khan

Electromagnetically induced transparency (EIT) is a phenomenon that can provide strong and robust interfacing between optical signals and quantum coherence of electronic spins. In its archetypical form, mainly explored with atomic media, it…

Coupled-resonance spectroscopy has been recently reported and applied for spectroscopic measurements and laser stabilizations. With coupled-resonance spectroscopy, one may indirectly measure some transitions between the excited states that…

Optics · Physics 2017-08-01 Junyi Zhang