Related papers: Evaluation of uranium-233 neutron capture cross se…
Accurate neutron capture cross sections are essential for the design and operation of fast reactors using MOX fuels. For $^{242}$Pu, the Nuclear Energy Agency (NEA) recommends 8--12% accuracy in the fast energy region (2--500 keV), compared…
Background:The design of new nuclear reactors and transmutation devices requires to reduce the present neutron cross section uncertainties of minor actinides. Purpose: Reduce the $^{243}$Am(n,$\gamma$) cross section uncertainty. Method: The…
The neutron capture cross section of 204Pb has been measured at the CERN n_TOF installation with high resolution in the energy range from 1 eV to 440 keV. An R-matrix analysis of the resolved resonance region, between 1 eV and 100 keV, was…
The 235U(n,f) cross section was measured in a wide energy range at n_TOF relative to 6Li(n,t) and 10B(n,alpha), with high resolution and in a wide energy range, with a setup based on a stack of six samples and six silicon detectors placed…
Several neutron capture cross sections of light neutron-rich nuclei were measured in the astrophysically relevant energy region of 5 to 200 keV. The experimental data are compared to calculations using the direct capture model. The results…
The neutron capture cross section of 26Mg was measured relative to the known gold cross section at thermonuclear energies using the fast cyclic activation technique. The experiment was performed at the 3.75 MV Van-de-Graaff accelerator,…
The neutron capture cross section of $^{154}$Gd was measured from 1 eV to 300 keV in the experimental area located 185 m from the CERN n\_TOF neutron spallation source, using a metallic sample of gadolinium, enriched to 67$\%$ in…
The aim of this work is to provide a precise and accurate measurement of the 238U(n,g) reaction cross section in the energy region from 1 eV to 700 keV. This reaction is of fundamental importance for the design calculations of nuclear…
The $^{63}$Ni($n, \gamma$) cross section has been measured for the first time at the neutron time-of-flight facility n\_TOF at CERN from thermal neutron energies up to 200 keV. In total, capture kernels of 12 (new) resonances were…
The $^{242}$Pu neutron-induced fission cross section was evaluated from 100 keV to 200 MeV. The experimental $^{242}$Pu and $^{235}$U fission cross sections and their ratios in the EXFOR library were reviewed and analysed by the…
The neutron-induced fission cross sections were simultaneously evaluated for the JENDL-5 library for $^{233,235}$U and $^{239,241}$Pu from 10 keV to 200 MeV and for $^{238}$U and $^{240}$Pu from 100 keV to 200 MeV. Evaluation was performed…
The neutron capture cross section of 48Ca was measured relative to the known gold cross section at kT = 52 keV using the fast cyclic activation technique. The experiment was performed at the Van-de-Graaff accelerator, Universitaet…
The $^{246}$Cm(n,$\gamma$) and $^{248}$Cm(n,$\gamma$) cross-sections have been measured at the Experimental Area 2 (EAR2) of the n_TOF facility at CERN with three C$_6$D$_6$ detectors. This measurement is part of a collective effort to…
The $^{232}$Th neutron-induced fission cross section was evaluated from 500 keV to 200 MeV. The experimental $^{232}$Th fission cross sections and their ratios to the $^{235,238}$U fission cross sections in the EXFOR library were reviewed…
The 232Th(n,{\gamma})233Th neutron capture reaction cross sections were measured at average neutron energies of 14.1 MeV and 14.8 MeV using the activation method. The neutron flux was determined using the monitor reaction…
Neutron total and capture cross sections of Lanthanum(La)-139 were measured at the Accurate Ne-utron-Nucleus Reaction measurement Instrument (ANNRI) of the Materials and Life Science Experimental Facility (MLF) in the Japan Proton…
The neutron capture cross section of Bi209 has been measured at the CERN n TOF facility by employing the pulse-height-weighting technique. Improvements over previous measurements are mainly because of an optimized detection system, which…
The $^{58}$Ni $(n,\gamma)$ cross section has been measured at the neutron time of flight facility n_TOF at CERN, in the energy range from 27 meV up to 400 keV. In total, 51 resonances have been analyzed up to 122 keV. Maxwellian averaged…
Neutron capture measurements on $^{155}$Gd and $^{157}$Gd were performed using the time-of-flight technique at the n\_TOF facility at CERN. Four samples in form of self-sustaining metallic discs isotopically enriched in $^{155}$Gd and…
Whether studying neutrinos for their own sake or as a messenger particle, neutrino cross sections are critically important for numerous analyses. On the low energy side, measurements from accelerator experiments reach up to a few 100s of…