Related papers: Exploring New Physics with PandaX-4T Low Energy El…
We report a search for new physics signals using the low energy electron recoil events in the complete data set from PandaX-II, in light of the recent event excess reported by XENON1T. The data correspond to a total exposure of 100.7…
We report a search on a sub-MeV fermionic dark matter absorbed by electrons with an outgoing active neutrino using the 0.63 tonne-year exposure collected by PandaX-4T liquid xenon experiment. No significant signals are observed over the…
We report the search results of light dark matter through its interactions with shell electrons and nuclei, using the commissioning data from the PandaX-4T liquid xenon detector. Low energy events are selected to have an ionization-only…
We present a novel constraint on light dark matter utilizing $1.54$ tonne$\cdot$year of data acquired from the PandaX-4T dual-phase xenon time projection chamber. This constraint is derived through detecting electronic recoil signals…
We present a search for light dark matter particles through their interactions with atomic electrons and nucleons, utilizing PandaX-4T data with an effective exposure of 1.04 tonne$\cdot$year for ionization-only data and 1.20…
We report on a blinded analysis of low-energy electronic-recoil data from the first science run of the XENONnT dark matter experiment. Novel subsystems and the increased 5.9 tonne liquid xenon target reduced the background in the (1, 30)…
We report the first dark matter search results using the commissioning data from PandaX-4T. Using a time projection chamber with 3.7-tonne of liquid xenon target and an exposure of 0.63 tonne$\cdot$year, 1058 candidate events are identified…
Axionlike particles (ALPs) and dark photons (DPs) are viable dark matter particle candidates. We have searched for possible ALP/DP signals in the PandaX-4T liquid xenon detector using 440 kg$\cdot$yr of data. A binned likelihood fit is…
We report constraints on light dark matter through its interactions with shell electrons in the PandaX-II liquid xenon detector with a total 46.9 tonne$\cdot$day exposure. To effectively search for these very low energy electron recoils,…
We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector. With an exposure of 0.65 t-y and an unprecedentedly low background rate of $76\pm2$ events/(t y keV) between 1 and 30…
We examine the recently-reported low-energy electron recoil spectrum observed at the XENON1T underground dark matter direct detection experiment, in the context of new interactions with solar neutrinos. In particular we show that scalar and…
PandaX-4T experiment is a deep-underground dark matter direct search experiment that employs a dual-phase time projection chamber with a sensitive volume containing 3.7 tonne of liquid xenon. The detector of PandaX-4T is capable of…
We report results from searches for new physics models via electron recoils using data collected by the LUX-ZEPLIN (LZ) experiment during its first two science runs, with a total exposure of 4.2 tonne-years. The observed data are consistent…
We report the first search for the elastic scatterings between cosmic-ray boosted sub-MeV dark matter and electrons in the PandaX-4T liquid xenon experiment. Sub-MeV dark matter particles can be accelerated by scattering with electrons in…
Neutron-induced nuclear recoil background is critical to the dark matter searches in the PandaX-4T liquid xenon experiment. This paper studies the feature of neutron background in liquid xenon and evaluates their contribution in the single…
The PandaX-4T experiment, a four-ton scale dark matter direct detection experiment, is being planned at the China Jinping Underground Laboratory. In this paper we present a simulation study of the expected background in this experiment. In…
Recently, two dark matter direct detection experiments have announced the first indications of nuclear recoils from solar $^8$B neutrinos via coherent elastic neutrino-nucleus scattering (CE$\nu$NS) with xenon nuclei. These results…
Motivated by the recent XENON1T results, we explore various new physics models that can be discovered through searches for electron recoils in O(keV)-threshold direct-detection experiments. First, we consider the absorption of light bosons,…
We report a systematic determination of the responses of PandaX-II, a dual phase xenon time projection chamber detector, to low energy recoils. The electron recoil (ER) and nuclear recoil (NR) responses are calibrated, respectively, with…
PandaX-4T is a dark matter direct detection experiment located in China jinping underground laboratory. The central apparatus is a dual-phase xenon detector containing 4 ton liquid xenon in the sensitive volume, with about 500…