English
Related papers

Related papers: A high rate and high timing photoelectric detector…

200 papers

We present a new design and assembly procedure of a large-area gas-avalanche Resistive-Plate WELL (RPWELL) detector. A $50\times50 ~\mathrm{cm^2}$ prototype was tested in $\mathrm{80 ~GeV/c}$ muon beam at CERN-SPS, presenting improved…

Instrumentation and Detectors · Physics 2023-07-19 D. Zavazieva , L. Moleri , A. Jash , G. Sela , F. de Vito-Halevy , S. Bressler

This paper has the purpose to study the rate capability of the Resistive Plate Chamber, RPC, starting from the basic physics of this detector. The effect of different working parameters determining the rate capability is analysed in detail,…

Instrumentation and Detectors · Physics 2016-08-03 G. Aielli , P. Camarri , R. Cardarelli , A. Di Ciaccio , L. Di Stante , R. Iuppa , B. Liberti , L. Paolozzi , E. Pastori , R. Santonico , M. Toppi

Resistive Plate Chamber (RPC) is one of the most commonly used detectors in high energy physics experiments for triggering and tracking because of its good efficiency ($\textgreater$~90\%) and time resolution ($\sim$~1-2~ns). Generally,…

Instrumentation and Detectors · Physics 2025-03-21 A. Sen , S. Mandal , S. Chatterjee , S. Gope , S. Das , S. Biswas

The performance and long term stability of an optically readout Time Projection Chamber with an electron amplification structure based on three Gas Electron Multipliers was studied. He/CF$_4$ based gas mixtures were used in two different…

The main challenges posed by the design of future Positron Emission Tomography machines are the improvement of the spatial and timing resolution and the combined operation with magnetic resonance. The Micro Pixel Photon Counter by Hamamatsu…

Medical Physics · Physics 2008-05-06 N. D'Ascenzo , E. Garutti , M. Goettlich , H. C. Schultz-Coulon , A. Tadday

A prototype of a single-gap glass Resistive Plate Chamber (RPC) is constructed by the authors. To find the considerations required for better operation of the detector's gas system, we have simulated the flow of the Ar gas through the…

Instrumentation and Detectors · Physics 2021-11-30 Yousef Pezeshkian , Amir Kiyoumarsioskouei , Majid Ahmadpouri , Ghasem Ghorbani

Large Area Picosecond PhotoDetectors (LAPPDs) are photosensors based on microchannel plate technology with about 400 cm$^2$ sensitive area. The external readout plane of a capacitively coupled LAPPD can be segmented into pads providing a…

A new prototype of large area Multi-gap Resistive Plate Chamber (MRPC) with long readout strips was built. This Long-strip Multi-gap Resistive Plate Chamber (LMRPC) is double stacked and has ten 250 $\mu$m-thick gas gaps. Signals are read…

Instrumentation and Detectors · Physics 2015-05-20 Yongjie sun , Cheng Li , Zebo Tang , Lailin Xu , Tianxiang Chen , Ming Shao

The Visible Light Photon Counter (VLPC) features high quantum efficiency and low pulse height dispersion. These properties make it ideal for efficient photon number state detection. The ability to perform efficient photon number state…

Quantum Physics · Physics 2007-05-23 Edo Waks , Kyo Inoue , Eleni Diamanti , Yoshihisa Yamamoto

Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing…

Instrumentation and Detectors · Physics 2016-04-19 J. W. Zhao , B. H. Sun , I. Tanihata , S. Terashima , L. H. Zhu , A. Enomoto , D. Nagae , T. Nishimura , S. Omika , A. Ozawa , Y. Takeuchi , T. Yamaguchi

Digital Hadronic Calorimeters (DHCAL) were suggested for future Colliders as part of the particle-flow concept. Though studied mainly with Resistive Plate Chambers (RPC), studies focusing on Micro-Pattern Gaseous Detector (MPGD)-based…

The standard gas mixture for the Resistive Plate Chambers (RPC), composed of C2H2F4/i-C4H10/SF6, allows the detector operation in avalanche mode, as required by the high-luminosity collider experiments. The gas density, the low current and…

Instrumentation and Detectors · Physics 2025-03-10 Giorgia Proto

A novel Resistive Plate Chamber (RPC) was designed with Diamond-Like Carbon (DLC) electrodes and performance studies were carried out for 384$\,\mathrm{\mu m}$ gap configuration with a $2\,\mathrm{cm}\times2\,\mathrm{cm}$ prototype. The use…

Instrumentation and Detectors · Physics 2024-01-25 Kei Ieki , Weiyuan Li , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Atsushi Oya , Masato Takahashi , Kensuke Yamamoto

The analog front-end electronics based on the constant fraction discrimination method is designed and optimized for the Multigap Resistive Plate Chamber (MRPC) timing measurements. The total time resolution of 40 ps has been obtained for 10…

Instrumentation and Detectors · Physics 2025-05-29 L. L. Kurchaninov , E. A. Ladygin , V. P. Ladygin , A. A. Semak

After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in…

Time projection chambers (TPCs) have found a wide range of applications in particle physics, nuclear physics, and homeland security. For TPCs with high-resolution readout, the readout electronics often dominate the price of the final…

Instrumentation and Detectors · Physics 2016-11-17 S. J. Ross , M. T. Hedges , I. Jaegle , M. D. Rosen , I. S. Seong , T. N. Thorpe , S. E. Vahsen , J. Yamaoka

A macroscopic reconstruction is developed to infer iRPC performance using Geant4 observables and one experimental anchor. The Geant4 energy deposition is used to estimate the primary ionization yield, while the efficiency turn-on is modeled…

Instrumentation and Detectors · Physics 2025-12-17 V. O. Ramirez-Beltran , Cecilia Uribe Estrada , Mauricio Flores Geronimo , François Lagarde

In the framework of the High Luminosity LHC upgrade program, the CMS muon group built several different RPC prototypes that are now under test at the new CERN Gamma Irradiation Facility (GIF++). A dedicated Detector Control System has been…

Instrumentation and Detectors · Physics 2019-08-13 Muhammad Gul , Genoveva Gonzalez

This paper reports on the time resolution of two photodetectors operated as single photon counters at high rate: a Hamamatsu R13742-103-M64 "conventional" (based on metal dynodes) multi-anode photomultiplier tube (MaPMT) and a Hamamatsu…

Instrumentation and Detectors · Physics 2020-12-30 M. Calvi , S. Capelli , P. Carniti , C. Gotti , G. Pessina

We developed a low-mass and high-efficiency charged particle detector for an experimental study of the rare decay $K_L \rightarrow \pi^0 \nu \bar{\nu}$. The detector is important to suppress the background with charged particles to the…

Instrumentation and Detectors · Physics 2016-02-03 D. Naito , Y. Maeda , N. Kawasaki , T. Masuda , H. Nanjo , T. Nomura , M. Sasaki , N. Sasao , S. Seki , K. Shiomi , Y. Tajima
‹ Prev 1 3 4 5 6 7 10 Next ›