Related papers: Dynamic Range of SiPMs with High Pixel Densities
For a long time, scintillator detectors have suffered from relatively weak spatial resolution due to various influencing factors. Additionally, the high cost of photomultiplier tubes (PMTs) has limited the widespread adoption of…
Astronomical observations with gamma rays in the range of several hundred keV to hundreds of MeV currently represent the least explored energy range. To address this so-called MeV gap, we designed and built a prototype CsI:Tl calorimeter…
In this study, we propose a fast implementation of a Maximum Likelihood Positioning (MLP) algorithm to estimate the energy and identify the active scintillator pixel in staggered layer scintillation detectors for PET. The staggered layer…
This paper presents the results of the proton irradiation of silicon photomulipliers (SiPMs) by mono-energetic 170 MeV protons with fluence up to 4.6$\times$10$^{9}$ particles/cm$^2$. In our work, three types of silicon photodetectors from…
SiPMs operate in Geiger mode, wherein photodiode cells are reverse-biased to the breakdown by even a single photon. Each cell is connected in series with a quenching resistor, which prevents cell damage and resets the cell after making a…
The current understanding of radiation tollerance of Silicon Photomultipliers (SiPMs) is reviewd. Radiation damage in silicon sensors is briefly introduced, surface and bulk effects are separately addressed. Results on the operation of…
In gamma ray imaging, a scintillation crystal is typically used to convert the gamma radiation into visible light. Photosensors are used to transform this light into measurable signals. Several types of photosensors are currently in use…
We describe a novel high-speed front-end electronic board (FEB) for interfacing an array of 32 Silicon Photo-multipliers (SiPM) with a computer. The FEB provides individually adjustable bias on the SiPMs, and performs low-noise analog…
The results obtained in laboratory tests, using scintillator bars read by silicon photomultipliers are reported. The present approach is the first step for designing a precision tracking system to be placed inside a free magnetized volume…
We developed a UV-transparent lens array that can increase the photon detection efficiency of a silicon photomultiplier (SiPM) array comprising of 64 pixels ($3\times3$ mm$^2$ each) and 0.2-mm gaps. Through the plano-convex spherical lens…
The Mu2e calorimeter is composed of 1400 un-doped CsI crystals, coupled to large area UV extended Silicon Photomultipliers (SiPMs), arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and…
Recent developments in photo-detectors and photo-detector systems are reviewed. The main emphasis is made on Silicon Photo-Multipliers (SiPM) - novel and very attractive photo-detectors. Their main features are described. Properties of…
Optical cross-talk is a critical characteristic of Silicon Photomultipliers (SiPMs) and represents a significant source of the excess noise factor, exerting a substantial influence on detector performance. During the avalanche process of…
The excellent production quality of recent generations of Silicon Photomultipliers (SiPMs) allows for operation without individual calibration of the breakdown voltage. Measurements of the crosstalk probability and the relative gain of 122…
The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved…
Accurate characterization of quantum yield is crucial to the reconstruction of energy depositions in silicon at the eV scale. This work presents a new method for experimentally calculating quantum yield using vacuum UV-sensitive silicon…
As a prototype detector for the SHiP Surrounding Background Tagger (SBT), we constructed a cell (120 cm x 80 cm x 25 cm) made from corten steel that is filled with liquid scintillator (LS) composed of linear alkylbenzene (LAB) and…
Among the top priorities for high-energy astronomy in the coming decade are sensitive surveys in the hard X-ray/soft \gamma-ray (10-600 keV) and medium-energy \gamma-ray (0.2-80 MeV) bands. Historically, observations in the soft and medium…
An established technique for the measurement of ultra-high-energy-cosmic-rays is the detection of the fluorescence light induced in the atmosphere of the Earth, by means of telescopes equipped with photomultiplier tubes. Silicon…
A light-emitting diode (LED) pulser for testing the low-rate response of a photomultiplier tube (PMT) to scintillator-like pulses has been designed, developed, and implemented. This pulser is intended to simulate 80 ns full width at half…