Related papers: Continued developments in X-ray speed reading: fas…
The SoLid collaboration have developed an intelligent readout system to reduce their 3200 silicon photomultiplier detector's data rate by a factor of 10000 whilst maintaining high efficiency for storing data from anti-neutrino interactions.…
The Advanced X-ray Imaging Satellite (AXIS), an astrophysics NASA probe mission currently in phase A, will provide high-throughput, high-spatial resolution X-ray imaging in the 0.3 to 10 keV band. We report on the notional ground…
CONCERTO is a millimeter-wave imaging instrument that operated on the Atacama Pathfinder Experiment (APEX) telescope from April 2021 to May 2023. Its primary scientific objectives include the study of galaxy clusters through the…
The X-ray Integral Field Unit (X-IFU) is an instrument of ESA's future NewAthena space observatory, with the goal to provide high-energy resolution ($<$ 4 eV at X-ray energies up to 7 keV) and high-spatial resolution (9") spectroscopic…
The next generation of cryogenic CMB and submillimeter cameras under development require densely instrumented sensor arrays to meet their science goals. The readout of large numbers ($\sim$10,000--100,000 per camera) of sub-Kelvin sensors,…
We discuss how future X-ray instruments which are under development can contribute to our understanding of the non-thermal Universe. Much progress has been made in the field of X-ray Astronomy recently, thanks to the operation of modern…
Recent advancements in particle physics demand pixel detectors that can withstand increased luminosity in the future collider experiments. In response, MALTA, a novel monolithic active pixel detector, has been developed with a cutting-edge…
Building upon existing signal processing techniques and open-source software, this paper presents a baseline design for an RF System-on-Chip Frequency Division Multiplexed readout for a spatio-spectral focal plane instrument based on low…
DEPFET pixel detectors are unique devices in terms of energy and spatial resolution because very low noise (ENC = 2.2e at room temperature) operation can be obtained by implementing the amplifying transistor in the pixel cell itself. Full…
In the scope of solar axion searches, detectors which are able to measure low energetic X-rays with high efficiency are required. For this purpose a detector based on the GridPix technology was built for the CAST experiment at CERN. The…
This paper presents a novel pixel chip readout scheme: the Region-of-Interest Readout Circuit (ROIRC), which is designed for large area, large array pixel chips and Gas Pixel Detector (GPD). This design employs a sentinel pixel detection…
ALICE, one of the experiments at the Large Hadron Collider (CERN), is undergoing ambitious upgrades during the ongoing second long shutdown (LS2). The main goal of this project is to access rare events and previously inaccessible physics…
We present a test platform for the Athena X-IFU detection chain, which will serve as the first demonstration of the representative end-to-end detection and readout chain for the X-IFU, using prototypes of the future flight electronics and…
Micromegas detector is a gas detector with parallel plate structure, and it consists of a conversion gap in which radiations liberate ionization electrons and a thin amplification gap. The signal of the micromegas detector consists of two…
The high time resolution observations of the X-ray sky hold the key to a number of diagnostics of fundamental physics, some of which are unaccessible to other types of investigations, such as those based on imaging and spectroscopy.…
A fast-reading current integrator is developed for high time-resolution and low-noise ion beam diagnostics under both continuous-wave and pulsed operating conditions. The system combines a low-leakage transimpedance front-end with a hybrid…
Space-based gamma-ray telescopes such as the Fermi Large Area Telescope have used single sided silicon strip detectors to measure the position of charged particles produced by incident gamma rays with high resolution. At energies in the…
Three key metrics for readout systems in quantum processors are measurement speed, fidelity and footprint. Fast high-fidelity readout enables mid-circuit measurements, a necessary feature for many dynamic algorithms and quantum error…
The physics aims at the proposed future CLIC high-energy linear $e^+ e^-$ collider pose challenging demands on the performance of the detector system. In particular the vertex and tracking detectors have to combine precision measurements…
For the upgrade of the inner tracker of the BESIII spectrometer, planned for 2018, a lightweight tracker based on an innovative Cylindrical Gas Electron Multiplier (CGEM) detector is now under development. The analogue readout of the CGEM…