Related papers: Spatial resolution studies using point spread func…
The spatial resolution of a detector, using a reference detector telecscope, can be measured applying the geometric mean method, with tracks reconstructed from hits of all the detectors, including ($\sigma_\mathrm{in}$) and excluding…
Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation…
Recent advances in photon detectors have resulted in high-density imaging arrays that offer many performance and cost advantages. In particular, the excellent transit time spread of certain devices show promise to provide tangible benefits…
In Charge Coupled Device (CCD) detectors the electrons excited upon absorption of a single x-ray photon quickly diffuse and generate charge-spots often larger than pixel dimensions. In the soft x-ray range this phenomenon drastically limits…
Stimulated Emission Depletion Microscopy (STED) can achieve a spatial resolution as high as several nanometers. As a point scanning imaging method, it requires 3D scanning to complete the imaging of 3D samples. The time-consuming 3D…
Transition Radiation Detectors (TRDs) are useful for electron identification and hadron suppression in high energy nuclear and particle physics experiments. Conventional wire-chamber TRDs face operational limitations due to space charge…
We have studied gain vs. voltage characteristics and position resolutions of multistep capillary plates (two or three capillary plates operating in a cascade), as well as capillary plates operating in a mode when the main amplification…
In this work a set of simulations that aim at the optimization of gaseous detectors for applications in X-ray fluorescence imaging in the energy range of 3 -- 30keV is presented. By studying the statistical distribution of the radiation…
With the arrival of the next generation of ultra-deep optical imaging surveys reaching $\mu_V$$\sim$30 mag/arcsec$^2$ (3$\sigma$; 10"$\times$10"), the removal of scattered light due to the point spread function (PSF) effect remains a…
Optical readout of large Time Projection Chambers (TPCs) with multiple Gas Electron Multipliers (GEMs) amplification stages has shown to provide very interesting performances for high energy particle tracking. Proposed applications for…
Gas Electron Multipliers (GEM) are among the more prominent Micro-Pattern Gaseous Detectors (MPGDs) and widely used in high energy particle physics experiments and various related applications. Adoption of different production techniques…
A critical challenge for the integration of the optoelectronics is that photodetectors have relatively poor sensitivities at the nanometer scale. It is generally believed that a large electrodes spacing in photodetectors is required to…
The combination of Micro-Pattern Gaseous Detectors (MPGDs) and pixel charge readout enables specific experimental opportunities. Using the Timepix4 for the readout is advantageous because of its size (around 7 cm^2 active area) and its…
We have developed and successfully used several innovative designs of detectors with solid photocathodes. The main advantage of these detectors is that rather high gains (>10E4) can be achieved in a single multiplication step. This is…
We present the first micropattern gaseous detector that employs a small 3D-printed Thick-GEM as its sole gain element. The detector can achieve sufficient gas gain for regular operation without the need for pre-amplification by additional…
This work illustrates and compares some methods to measure the most relevant parameters of silicon photo-multipliers (\sipm{}s), such as photon detection efficiency as a function of over-voltage and wavelength, dark count rate, optical…
Orbital angular momentum (OAM) recognition of vortex beams is critical for applications ranging from optical communications to quantum technologies. However, conventional approaches designed for free-space propagation struggle when light…
To solve the discharge of the standard Bulk Micromegas and GEM detector, the GEM-Micromegas detector was developed in Institute of High Energy Physics. Taking into account the advantages of the two detectors, one GEM foil was set as a…
Combining gaseous detectors with a high-granularity pixelated charge readout enables experimental applications which otherwise could not be achieved. This includes high-resolution tracking of low-energetic particles, requiring ultra-low…
In this paper, limitations of the common method measuring intrinsic spatial resolution of the GEM imaging detector are presented. Through theoretical analysis and experimental verification, we have improved the common method to avoid these…