Related papers: Multi-Amplifier Sensing Charge-coupled Devices for…
Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detection technology that can, in principle, provide significantly greater responsivity and improved noise performance than traditional charge coupled device (CCD)…
A radically new CCD development by Marconi Applied Technologies has enabled substantial internal gain within the CCD before the signal reaches the output amplifier. With reasonably high gain, sub-electron readout noise levels are achieved…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
X-ray Charge Coupled Devices (CCDs) have been the workhorse for soft X-ray astronomical instruments for the past quarter century. They provide broad energy response, extremely low electronic read noise, and good energy resolution in soft…
We characterize the response of a novel 250 $\mu$m thick, fully-depleted Skipper Charged-Coupled Device (CCD) to visible/near-infrared light with a focus on potential applications for astronomical observations. We achieve stable,…
The Advanced ACTPol (AdvACT) upgrade to the Atacama Cosmology Telescope (ACT) features arrays of aluminum manganese transition-edge sensors (TESes) optimized for ground-based observations of the Cosmic Microwave Background (CMB). Array…
Low noise CCDs fully-depleted up to 675 micrometers have been identified as a unique tool for Dark Matter searches and low energy neutrino physics. The charge collection efficiency (CCE) for these detectors is a critical parameter for the…
Charge Coupled Devices (CCDs) have been successfully used in several low energy X-ray astronomical satellite over the past two decades. Their high energy resolution and high spatial resolution make them an perfect tool for low energy…
We have developed a non-destructive readout system that uses a floating-gate amplifier on a thick, fully depleted charge coupled device (CCD) to achieve ultra-low readout noise of 0.068 e- rms/pix. This is the first time that discrete…
High precision and large dynamic range measurement are required in the readout systems for the Water Cherenkov Detector Array (WCDA) in Large High Altitude Air Shower Observatory (LHAASO). This paper presents a prototype of 12-bit 40 MSPS…
The Phase-II Upgrade of the ATLAS Muon Detector requires new electronics for the readout of the MDT drift tubes. The first processing stage, the Amplifier-Shaper-Discriminator (ASD), determines the performance of the readout for crucial…
Transition-edge sensor (TES) is a highly sensitive device that is capable of detecting extremely low levels of energy. It is characterised by low noise performance and high energy resolution. A mature method for reading out TES signal is…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
Future strategic X-ray missions, such as the Advanced X-ray Imaging Satellite (AXIS) and those targeted by the Great Observatories Maturation Program (GOMaP), require fast, low-noise X-ray imaging spectrometers. To achieve the speed and…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
The \emph{MIDNA} application specific integrated circuit (ASIC) is a skipper-CCD readout chip fabricated in a 65 nm LP-CMOS process that is capable of working at cryogenic temperatures. The chip integrates four front-end channels that…
Recent clinical evidence shows a correlation between linear energy transfer (LET) and tumor control in carbon ion radiotherapy. This prompts the direct inclusion of LET into the treatment planning. Currently, LET is mainly extracted from…
Cluster counting dN/dx is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good pion-kaon separation over a broad momentum range is…
We report on the performance of an analog application-specific integrated circuit (ASIC) developed aiming for the front-end electronics of the X-ray CCDcamera system onboard the next X-ray astronomical satellite, ASTRO-H. It has four…
We report on the design and performance of a mixed-signal application specific integrated circuit (ASIC) dedicated to avalanche photodiodes (APDs) in order to detect hard X-ray emissions in a wide energy band onboard the International Space…