Related papers: Measurement of Ionization Produced by 254 eVnr Nuc…
This article reports the measurement of the ionization quenching factor in germanium for nuclear recoil energies between 0.4 and 6.3 keV$_{nr}$. Precise knowledge of this factor in this energy range is relevant for coherent elastic…
We report a measurement of the ionization efficiency of silicon nuclei recoiling with sub-keV kinetic energy in the bulk silicon of a charge-coupled device (CCD). Nuclear recoils are produced by low-energy neutrons ($<$24 keV) from a…
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for…
The ionization yield in the two-phase liquid xenon dark-matter detector has been studied in keV nuclear-recoil energy region. The newly-obtained nuclear quenching as well as the recently-measured average energy required to produce an…
We employ an $^{88}$Y/Be photoneutron source to derive the quenching factor for neutron-induced nuclear recoils in germanium, probing recoil energies from a few hundred eV$_{nr}$ to 8.5keV$_{nr}$. A comprehensive Monte Carlo simulation of…
Germanium is the detector material of choice in many rare-event searches looking for low-energy nuclear recoils induced by dark matter particles or neutrinos. We perform a systematic exploration of its quenching factor for sub-keV nuclear…
Nuclear recoil ionization yield constitutes a critical uncertainty source in low-energy detection for dark matter (DM) and coherent elastic neutrino-nucleus scattering (CE$\nu$NS) experiments. We present a novel methodology employing…
In the recent years, argon-based experiments looking for Dark Matter in the Universe have explored the non-standard scenario in which Dark Matter is made by low-mass Weakly Interacting Massive Particles, of mass in the range of 1-10 GeV…
We report the first measurements of the absolute ionization yield of nuclear recoils in liquid xenon, as a function of energy and electric-field. Independent experiments were carried out with two dual-phase time projection chamber…
The discrepancies in claims of experimental evidence in the search for weakly interacting massive particle (WIMP) dark matter necessitate a model for ionization efficiency (the quenching factor) at energies below 10 keV. We have carefully…
Dual-phase xenon TPC detectors are a highly scalable and widely used technology to search for low-energy nuclear recoil signals from WIMP dark matter or coherent nuclear scattering of $\sim$MeV neutrinos. Such experiments expect to measure…
Liquid xenon is an important detection medium in direct dark matter experiments, which search for low-energy nuclear recoils produced by the elastic scattering of WIMPs with quarks. The two existing measurements of the relative…
Low-energy nuclear recoils (NRs) are hard to measure because they produce few e$^{-}$/h$^+$ pairs in solids -- i.e. they have low "ionization yield". A silicon detector was exposed to thermal neutrons over 2.5\,live-days, probing NRs down…
Liquid xenon-based direct detection dark matter experiments have recently expanded their searches to include high-energy nuclear recoil events as motivated by effective field theory dark matter and inelastic dark matter interaction models,…
We present a model of the ionization efficiency, or quenching factor, for low-energy nuclear recoils, based on a solution to Lindhard integral equation with binding energy and apply it to the calculation of the relative scintillation…
Dark matter (DM) particles with mass in the sub-GeV range are an attractive alternative to heavier weakly-interacting massive particles, but direct detection of such light particles is challenging. If however DM-nucleus scattering leads to…
Recent measurements of the germanium quenching factor deviate significantly from the predictions of the standard Lindhard model for nuclear recoil energies below a keV. This departure may be explained by the Migdal effect in neutron…
We used the internal conversion ($E_0$ transition) of germanium-72 to indirectly measure the low energy nuclear recoils of germanium. Together with a reliable Monte Carlo package, in which we implement the internal conversion process, the…
The energy calibration of nuclear recoil detectors is of primary importance to rare-event experiments such as those of direct dark matter search and coherent neutrino-nucleus scattering. In particular, such a calibration is performed by…
XENON10 is an experiment designed to directly detect particle dark matter. It is a dual phase (liquid/gas) xenon time-projection chamber with 3D position imaging. Particle interactions generate a primary scintillation signal (S1) and…