English
Related papers

Related papers: Cryogenic optical beam steering for superconductin…

200 papers

Encoding information onto optical fields is the backbone of modern telecommunication networks. Optical fibers offer low loss transport and vast bandwidth compared to electrical cables, and are currently also replacing coaxial cables for…

A light-beam-assisted temperature-control system operating within a temperature range from 77 to 180 K is developed for investigating the absorption of electromagnetic waves by high-temperature superconductors in the vicinity of…

Superconductivity · Physics 2019-08-17 M. K. Aliev , G. R. Alimov , I. Kholbaev , T. M. Muminov , B. Olimov , B. Yu. Sokolov , R. R. Usmanov

Measurements of the polarization of the cosmic microwave background (CMB) radiation are expected to significantly increase our understanding of the early universe. We present a design for a CMB polarimeter in which a cryogenically cooled…

Astrophysics · Physics 2016-11-17 S. Hanany , T. Matsumura , B. Johnson , T. Jones , J. R. Hull , K. B. Ma

Micro- and nanothermometry enable precise temperature monitoring and control at the micro- and nanoscale, and have become essential diagnostic tools in applications ranging from high-power microelectronics to biosensing and nanomedicine.…

Materials Science · Physics 2025-10-28 Md Shakhawath Hossain , Dylan G. Stone , G. Landry , Xiaoxue Xu , Carlo Bradac , Toan Trong Tran

We report on the status and development of polarization-sensitive detectors for millimeter-wave applications. The detectors are fabricated on single-crystal silicon, which functions as a low-loss dielectric substrate for the microwave…

We present a superconducting microresonator thermometer based on two-level systems (TLS) that is drop-in compatible with cryogenic microwave systems. The operational temperature range is 50-1000~mK (which may be extended to 5~mK), and the…

Instrumentation and Detectors · Physics 2020-11-16 J. Wheeler , M. R. Vissers , M. Malnou , J. Hubmayr , J. N. Ullom , J. Gao

The reorientational nonlinearity of nematic liquid crystals enables a self-localized spatial soliton and its waveguide to be deflected or destroyed by a control beam propagating across the cell. We demonstrate a simple all-optical…

Advances in cryogenic electron microscopy have opened new avenues for probing quantum phenomena in correlated materials. This study reports the installation and performance of a new side-entry condenZero cryogenic cooling system for JEOL…

Strongly Correlated Electrons · Physics 2025-09-30 Young-Hoon Kim , Fehmi Sami Yasin , Na Yeon Kim , Max Birch , Xiuzhen Yu , Akiko Kikkawa , Yasujiro Taguchi , Jiaqiang Yan , Miaofang Chi

The development of high-quality solid-state photon sources is essential to nano optics, quantum photonics, and related fields. A key objective of this research area is to develop tunable photon sources that not only enhance the performance…

We describe a versatile apparatus for optical observations of experimental processes at temperatures down to 0.1 K. The cooling is achieved by a wet cryostat with a dilution refrigerator on a vibrationally-isolated platform, capable of…

Other Condensed Matter · Physics 2026-02-26 I. Skachko , J. A. Hay , C. O. Goodwin , M. J. Doyle , W. Guo , P. M. Walmsley , A. I. Golov

Semiconductor integrated circuits operated at cryogenic temperature will play an essential role in quantum computing architectures. These can offer equivalent or superior performance to their room-temperature counterparts while enabling a…

Mesoscale and Nanoscale Physics · Physics 2025-07-18 Jonathan Eastoe , Grayson M. Noah , Debargha Dutta , Alessandro Rossi , Jonathan D. Fletcher , Alberto Gomez-Saiz

Microscopes and various forms of interferometers have been used for decades in optical metrology of objects that are typically larger than the wavelength of light {\lambda}. However, metrology of subwavelength objects was deemed impossible…

The displacement of micro-electro-mechanical-systems (MEMS) cantilevers is used to measure a broad variety of phenomena in devices ranging from force microscopes to biochemical sensors to thermal imaging systems. We demonstrate the first…

Quantum Physics · Physics 2016-11-25 R. C. Pooser , B. J. Lawrie

Electron microscopy has enabled many scientific breakthroughs across multiple fields. A key challenge is the tuning of microscope parameters based on images to overcome optical aberrations that deteriorate image quality. This calibration…

Computer Vision and Pattern Recognition · Computer Science 2026-03-20 Jilles S. van Hulst , W. P. M. H. Heemels , Duarte J. Antunes

In regular magneto-optical trap (MOT) systems, the delivery of six circularly polarized (CP) cooling beams requires complex and bulky optical arrangements including waveplates, mirrors, retroreflectors, etc. To address such technique…

We introduce the Michigan Infrared Test Thermal ELT N-band (MITTEN) Cryostat, a new facility for testing infrared detectors with a focus on mid-infrared (MIR) wavelengths (8-13 microns). New generations of large format, deep well, fast…

Instrumentation and Methods for Astrophysics · Physics 2020-12-16 R. Bowens , E. Viges , M. R. Meyer , D. Atkinson , J. Monnier , M. Morgenstern , J. Leisenring , W. Hoffmann

Future sky surveys in the mm/sub-mm range, like the forthcoming balloon-borne missions LSPE, OLIMPO, SPIDER etc., will need detectors insensitive to cosmic rays (CRs) and with a NEP of the order of $10^{-17} \div 10^{-18}\,$W/sqrt(Hz). The…

Instrumentation and Methods for Astrophysics · Physics 2014-10-23 Maria Salatino , Paolo de Bernardis , Sumedh Mahashabde , Leonid S. Kuzmin , Silvia Masi

The availability and performance of laser-based adaptive optics (AO) systems are strongly dependent on the power and quality of the laser beam before being projected to the sky. Frequent and time-consuming alignment procedures are usually…

Instrumentation and Methods for Astrophysics · Physics 2014-05-23 Clémentine Béchet , Andrés Guesalaga , Benoit Neichel , Vincent Fesquet , Héctor González-Núñez , Sebastián Zúñiga , Pedro Escarate , Dani Guzman

The calibration of the ICARUS photo-detection system is based on a low power laser diode at 405 nm. Laser pulses arrive to one optical switch and then are sent to 36 UHV flanges, by 20 meters long optical patches. Light is then delivered to…

Instrumentation and Detectors · Physics 2022-12-21 M. Bonesini , R. Benocci , R. Bertoni , A. Chatterjee , M. Diwan , A. Menegolli , G. Raselli , M. Rossella , A. Scarpelli , N. Suarez
‹ Prev 1 3 4 5 6 7 10 Next ›