Dark-field x-ray microscopy utilizes Bragg diffraction to collect full-field x-ray images of "mesoscale" structure of ordered materials. Information regarding the structural heterogeneities and their physical implications is gleaned through…
Most image deblurring methods assume an over-simplistic image formation model and as a result are sensitive to more realistic image degradations. We propose a novel variational framework, that explicitly handles pixel saturation, noise,…
We reported the usage of grating-based X-ray phase-contrast imaging in nondestructive testing of grating imperfections. It was found that electroplating flaws could be easily detected by conventional absorption signal, and in particular, we…
The values of the signal-to-noise ratio are determined, at which the method of processing X-ray diffraction data reveals reflections with intensity less than the noise component of the background. The possibilities of the method are…
Dark-field X-ray microscopy is a new full-field imaging technique that nondestructively maps the structure and local strain inside deeply embedded crystalline elements in three dimensions. Placing an objective lens in the diffracted beam…
Grating interferometry is a promising diagnostic technique that enables simultaneous acquisition of three complementary, synergistic X-ray images: transmission, differential phase, and dark-field. Its key advantage over other setups is its…
Solving crystal structures from powder X-ray diffraction (XRD) is a central challenge in materials characterization. In this work, we study the powder XRD-to-structure mapping using gradient descent optimization, with the goal of recovering…
The surface figure of x-ray mirrors can be improved by differential deposition of thin films. To achieve the required corrections, WSi2 layers of variable thickness were deposited through beam-defining apertures of different openings. The…
Conventional x-ray imaging detectors suffer from parallax error when the radiation beam arrives at the detector surface at tilted angle. The image blurring occurs as the radiation penetrates detector material in lateral direction at tilted…
X-ray imaging is the most widely used medical imaging modality. However, in the common practice, inconsistency in the initial presentation of X-ray images is a common complaint by radiologists. Different patient positions, patient habitus…
X-ray interferometry is an emerging imaging modality with a wide variety of potential clinical applications, including lung imaging. A grating interferometer uses a diffraction grating to produce a periodic interference pattern and measures…
X-ray fluorescence holography (XFH) is a method for obtaining diffraction-limited images of the local atomic structure around a given type of emitter. The reconstructed wave-field represents a distorted image of the scatterer electron…
Most of the standard image and video codecs are block-based and depending upon the compression ratio the compressed images/videos suffer from different distortions. At low ratios, blurriness is observed and as compression increases blocking…
Diffraction imaging of non-equilibrium dynamics at atomic resolution is becoming possible with X-ray free-electron lasers. However, there are unresolved problems with applying this method to objects that are confined in only one dimension.…
Atmospheric turbulence can significantly degrade the quality of images acquired by long-range imaging systems by causing spatially and temporally random fluctuations in the index of refraction of the atmosphere. Variations in the refractive…
X-ray phase contrast tomography (XPCT) is widely used for 3D imaging of objects with weak contrast in X-ray absorption index but strong contrast in refractive index decrement. To reconstruct an object imaged using XPCT, phase retrieval…
A resolution-enhanced dark-field microscope by structured light illumination is proposed to improve resolution and contrast. A set of phase-shifted fringes are projected to the sample plane at large angle to capture modulated dark-field…
The displacement field in highly non uniformly strained crystals is obtained by addition of constraints to an iterative phase retrieval algorithm. These constraints include direct space density uniformity and also constraints to the sign…
We develop a speckle-tracking method for x-ray phase-contrast imaging, based on the concept of geometric flow. This flow is a conserved current associated with deformation of illuminating x-ray speckles induced by passage through a sample.…
In this investigation, we applied a single-projection dark-field imaging technique to gain statistical information on the smallest airway structures within the lung$\unicode{x2014}$the alveoli$\unicode{x2014}$focusing on their size and…