Related papers: Validating a lutetium frequency reference
The new generation of atomic clocks will reach unprecedented uncertainties in frequency of $10^{-18}$. In order to prepare space missions such as ACES, we compute all relativistic frequency shifts detectable during this mission in the case…
We have measured the 1S - 2S transition frequency in atomic hydrogen via two photon spectroscopy on a 5.8 K atomic beam. We obtain $f_{1S-2S} = 2 466 061 413 187 035 (10)$ Hz for the hyperfine centroid. This is a fractional frequency…
Accurate time transfer has become a crucial issue for future space experiments which require increasing resolution over large distances. In 2008, a scheme combining homodyne detection and mode-locked femtosecond lasers was proposed that…
We obtain analytical approximations for the expectation and variance of the Spectral Kurtosis estimator in the case of Gaussian and coherent transient time domain signals mixed with a quasi-stationary Gaussian background, which are suitable…
An understanding of pulsar timing noise offers the potential to improve the timing precision of a large number of pulsars as well as facilitating our understanding of pulsar magnetospheres. For some sources, timing noise is attributable to…
We demonstrate a technique for frequency measurements of atomic transitions with a precision of 30 kHz. The frequency is measured using a ring-cavity resonator whose length is calibrated against a reference laser locked to the $D_2$ line of…
With direct polarizability measurements we demonstrated extremely low sensitivity of the inner-shell clock transition at $1.14\,\mu$m in Tm atoms to external dc electric fields and black-body radiation (BBR). We measured differential…
The precise measurement of molecular vibrational transition frequencies is useful in the search for variation in the proton-to-electron mass ratio {\mu}. Homonuclear diatomic molecules are particularly advantageous for precise measurement…
The absolute frequency of the 1S0-3P0 clock transition of 87Sr has been measured to be 429 228 004 229 873.65 (37) Hz using lattice-confined atoms, where the fractional uncertainty of 8.6x10-16 represents one of the most accurate…
Transition frequencies between low-lying energy levels in a single trapped $^{138}$Ba$^{+}$ ion have been measured with laser spectroscopy referenced to an optical frequency comb. By extracting the frequencies of one-photon and two-photon…
A two-photon transition in laser-cooled and trapped calcium atoms is proposed as the atomic reference in an optical frequency standard. An efficient scheme for interrogation of the frequency standard is described, and the sensitivity of the…
We show that PT-symmetry may exist only for isolated frequencies in optical systems. Therefore, PT-symmetry breaking transitions as the frequency is tuned up, discussed in Y. D. Chong, L. Ge, and A. D. Stone, Phys. Rev. Lett. 106, 093902…
The CH radical offers a sensitive way to test the hypothesis that fundamental constants measured on earth may differ from those observed in other parts of the universe. The starting point for such a comparison is to have accurate laboratory…
This article describes the recent progress of optical lattice clocks with neutral strontium ($^{87}$Sr), ytterbium ($^{171}$Yb) and mercury ($^{199}$Hg) atoms. In particular, we present frequency comparison between the clocks locally via an…
We follow the temporal evolution of mesoscopic intensity fluctuations and correlation in strongly localized samples. We find an initial burst in relative transmission fluctuations in random one dimensional (1D) samples due to fluctuations…
By using two-way frequency transfer, we demonstrate ultra-high resolution comparison of optical frequencies over a telecommunication fiber link of 100 km operating simultaneously digital data transfer. We first propose and experiment a…
The comparison of different atomic transition frequencies over time can be used to determine the present value of the temporal derivative of the fine structure constant alpha in a model-independent way without assumptions on constancy or…
The increasing penetration of renewable energy leads to a continuous reduction in system inertia, for which conventional synchronization criteria based solely on frequency consistency can no longer accurately capture the coupled dynamics of…
High-precision spectroscopy of simple atomic systems can be used to advance the theory of atomic energy levels but can also serve as a sensitive probe of nuclear charge radii. For this last purpose, we report an improved measurement of the…
High precision spectroscopy of the $^1S_0$-to-${^1}D_2$ clock transition of $^{176}$Lu is reported. Measurements are performed with Hertz level precision with the accuracy of the hyperfine-averaged frequency limited by the calibration of an…