English
Related papers

Related papers: Laser Frequency Stabilization Using Light Shift in…

200 papers

A two-photon transition in laser-cooled and trapped calcium atoms is proposed as the atomic reference in an optical frequency standard. An efficient scheme for interrogation of the frequency standard is described, and the sensitivity of the…

Atomic Physics · Physics 2015-01-09 Amar C. Vutha

Arm locking is a technique that has been proposed for reducing laser frequency fluctuations in the Laser Interferometer Space Antenna (LISA), a gravitational-wave observatory sensitive in the milliHertz frequency band. Arm locking takes…

General Relativity and Quantum Cosmology · Physics 2011-06-13 James Ira Thorpe , Peiman Maghami , Jeffrey Livas

To achieve sub-picometer sensitivities in the millihertz band, laser interferometric inertial sensors rely on some form of reduction of the laser frequency noise, typically by locking the laser to a stable frequency reference, such as the…

The $^1\mathrm{S}_0$-$^3\mathrm{P}_0$ clock transition frequency $\nu_\text{Sr}$ in neutral $^{87}$Sr has been measured relative to the Cs standard by three independent laboratories in Boulder, Paris, and Tokyo over the last three years.…

We demonstrate a technique to lock simultaneously two laser frequencies to each step of a two-photon transition in the presence of a magnetic field sufficiently large to gain access to the hyperfine Paschen-Back regime. A ladder…

With ultracold $^{87}$Sr confined in a magic wavelength optical lattice, we present the most precise study (2.8 Hz statistical uncertainty) to-date of the $^1S_0$ - $^3P_0$ optical clock transition with a detailed analysis of systematic…

We have commissioned the digital Low Level RF (LLRF) system for storage ring RF at Advanced Light Source at Lawrence Berkeley National Lab (LBNL). The system is composed of 42 synchronous sampling channels for feedback control, diagnostics,…

Atom interferometry on optical clock transitions is being pursued for numerous long-baseline experiments both terrestrially and for future space missions. Crucial to meeting these experiments' required sensitivities is the implementation of…

Improving the clock stability is of fundamental importance for the development of quantum-enhanced metrology. One of the main limitations arises from the randomly-fluctuating local oscillator (LO) frequency, which introduces "phase slips"…

Quantum Physics · Physics 2022-06-01 Weidong Li , Shuyuan Wu , Augusto Smerzi , Luca Pezzè

We demonstrate a lock-in particle tracking scheme in optical tweezers based on stroboscopic modulation of an illuminating optical field. This scheme is found to evade low frequency noise sources while otherwise producing an equivalent…

Optics · Physics 2014-09-04 Michael A Taylor , Joachim Knittel , Warwick P Bowen

A high performance Space-Time Reference in orbit could be realized using a stable atomic clock in a precisely defined orbit and linking that to high accuracy atomic clocks on the ground using a laser based time-transfer link. This would…

Optics · Physics 2017-08-23 Paul Berceau , Leo Hollberg

We propose a method to continuously frequency shift a target laser that is frequency stabilized by a reference laser, which is several hundreds of nanometers detuned. We demonstrate the technique using the 5S 1/2 to 5P 3/2 to 29D 5/2…

We describe an optical frequency stabilization scheme of a microwave oscillator that is used for the interrogation of primary caesium fountain clocks. Because of its superior phase noise properties, this scheme, which is based on an…

Atomic Physics · Physics 2018-10-22 Burghard Lipphardt , Vladislav Gerginov , Stefan Weyers

The stability of an optical atomic clock is a critical figure of merit for almost all clock applications. To this end, much optical atomic clock research has focused on reducing clock instability by increasing the atom number, lengthening…

Atomic Physics · Physics 2023-12-21 Xin Zheng , Jonathan Dolde , Shimon Kolkowitz

Operating atom-interferometer gyroscopes outside a laboratory environment is challenging primarily owing to the instability of laser systems. To enhance the thermal stability of free-space laser systems, a compact laser system using fiber…

We investigate the magnetic-field-induced frequency shift (MFS) of the clock "0-0" transition in the microwave quantum frequency standard (atomic clock) based on coherent population trapping (CPT) in $^{87}$Rb vapor. To scan the CPT…

Atomic Physics · Physics 2025-04-28 V. I. Vishnyakov , D. V. Brazhnikov , M. N. Skvortsov

We present a novel method for engineering an optical clock transition that is robust against external field fluctuations and is able to overcome limits resulting from field inhomogeneities. The technique is based on the application of…

Atomic Physics · Physics 2019-12-03 Nati Aharon , Nicolas Spethmann , Ian D. Leroux , Piet O. Schmidt , Alex Retzker

Time and frequency are the most accurately measurable quantities, providing foundations for science and modern technologies. The accuracy relies on the SI (Syst\'eme International) second that refers to Cs microwave clocks with fractional…

Atomic Physics · Physics 2014-05-19 Ichiro Ushijima , Masao Takamoto , Manoj Das , Takuya Ohkubo , Hidetoshi Katori

The advancement of technologies for the precise interrogation of molecules offers exciting possibilities for new studies in the realms of precision spectroscopy and quantum technologies. Experiments in these domains often address molecular…

Optics · Physics 2022-09-15 Mudit Sinhal , Anatoly Johnson , Stefan Willitsch

We demonstrate a method for accurately locking the frequency of a continuous-wave laser to an optical frequency comb in conditions where the signal-to-noise ratio is low, too low to accommodate other methods. Our method is typically orders…

‹ Prev 1 8 9 10 Next ›