Related papers: Spiral Scanning and Self-Supervised Image Reconstr…
For 3D Synthetic Aperture Radar (SAR) imaging, one typical approach is to achieve the cross-track 1D focusing for each range-azimuth pixel after obtaining a stack of 2D complex-valued images. The cross-track focusing is the main difficulty…
Ultrasound imaging is widely used due to its safety, affordability, and real-time capabilities, but its 2D interpretation is highly operator-dependent, leading to variability and increased cognitive demand. 2D-to-3D reconstruction mitigates…
Image Phase Alignment Super-Sampling (ImPASS) is a computational imaging algorithm for converting a sequence of displaced low-resolution images into a single high-resolution image. The method consists of a unique combination of Phase…
The existing barely-supervised medical image segmentation (BSS) methods, adopting a registration-segmentation paradigm, aim to learn from data with very few annotations to mitigate the extreme label scarcity problem. However, this paradigm…
Multi-spectral imaging, which simultaneously captures the spatial and spectral information of a scene, is widely used across diverse fields, including remote sensing, biomedical imaging, and agricultural monitoring. Here, we introduce a…
Acoustic-Resolution Photoacoustic Microscopy (AR-PAM) is promising for subcutaneous vascular imaging, but its spatial resolution is constrained by the Point Spread Function (PSF). Traditional deconvolution methods like Richardson-Lucy and…
We demonstrate a compact, cost-effective snapshot spectral imaging system named Aperture Diffraction Imaging Spectrometer (ADIS), which consists only of an imaging lens with an ultra-thin orthogonal aperture mask and a mosaic filter sensor,…
Panoptic segmentation of 3D scenes, involving the segmentation and classification of object instances in a dense 3D reconstruction of a scene, is a challenging problem, especially when relying solely on unposed 2D images. Existing…
We investigate resolution in photoacoustic tomography (PAT). Using Shannon theory, we investigate the theoretical resolution limit of sparse view PAT theoretically, and empirically demonstrate that all reconstruction methods used exceed…
This paper proposes a subspace decomposition method based on an over-complete dictionary in sparse representation, called "Sparse Signal Subspace Decomposition" (or 3SD) method. This method makes use of a novel criterion based on the…
Accurate segmentation of anatomical structures in ultrasound (US) images, particularly small ones, is challenging due to noise and variability in imaging conditions (e.g., probe position, patient anatomy, tissue characteristics and…
Sparse-view computed tomography (CT) is known as a widely used approach to reduce radiation dose while accelerating imaging through lowered projection views and correlated calculations. However, its severe imaging noise and streaking…
Sparse-view computed tomography (CT) enables fast and low-dose CT imaging, an essential feature for patient-save medical imaging and rapid non-destructive testing. In sparse-view CT, only a few projection views are acquired, causing…
Ultrasound Localization Microscopy (ULM) has presented great potential in functional imaging, benefiting from its ability to reconstruct deep microvasculature. However, the hemodynamic reconstruction is compromised by sparsity in the ULM…
We propose a model-based image reconstruction method for photoacoustic tomography(PAT) involving a novel form of regularization and demonstrate its ability to recover good quality images from significantly reduced size datasets. The…
Active stereo technique using single pattern projection, a.k.a. one-shot 3D scan, have drawn a wide attention from industry, medical purposes, etc. One severe drawback of one-shot 3D scan is sparse reconstruction. In addition, since spatial…
Ultrasound Localization Microscopy (ULM) has recently enabled the mapping of the cerebral vasculature in vivo with a resolution ten times smaller than the wavelength used, down to ten microns. However, with frame rates up to 20.000 frames…
Ultrasound imaging is challenging to interpret due to non-uniform intensities, low contrast, and inherent artifacts, necessitating extensive training for non-specialists. Advanced representation with clear tissue structure separation could…
Magnetic resonance imaging (MRI) is mainly limited by long scanning time and vulnerable to human tissue motion artifacts, in 3D clinical scenarios. Thus, k-space undersampling is used to accelerate the acquisition of MRI while leading to…
Optoacoustic tomography (OAT), also known as photoacoustic tomography, is a rapidly emerging hybrid imaging technique that possesses great potential for a wide range of biomedical imaging applications. In OAT, a laser is employed to…