Related papers: Enabling pulse shape discrimination with commercia…
A successfull application of Geiger-mode multipixel avalanche diodes (GMAPDs) for pulse-shape discrimination in alpha-beta spectrometry using organic liquid scintillator is described in this paper. Efficient discrimination of alpha and beta…
A convolutional neural network (CNN) architecture is developed to improve the pulse shape discrimination (PSD) power of the gadolinium-loaded organic liquid scintillation detector to reduce the fast neutron background in the inverse beta…
This review presents a comprehensive survey and benchmark of pulse shape discrimination (PSD) algorithms for radiation detection, classifying nearly sixty methods into statistical (time-domain, frequency-domain, neural network-based) and…
The LaBr3:Ce scintillator has been widely studied for nuclear spectroscopy because of its optimal energy resolution (<3%@ 662 keV) and time resolution (~300 ps). Despite these promising properties, the intrinsic radiation background of…
There are recent interests with CsI(Tl) scintillating crystals for Dark Matter experiments. The key merit is the capability to differentiate nuclear recoil (nr) signatures from the background $\beta / \gamma$-events due to ambient…
The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is…
In a dedicated test setup at the Kamioka Observatory we studied pulse shape discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe was based on the observation that scintillation light from electron events was…
The scintillation mechanism in NaI:Tl crystals produces different pulse shapes that are dependent on the incoming particle type. The time distribution of scintillation light from nuclear recoil events decays faster than for electron recoil…
Traditionally, neutron-$\gamma$ discrimination in organic scintillators relies on techniques such as time-of-flight (ToF) selection and pulse-shape discrimination (PSD). However, particle identification through graphical cuts remains…
We report the first clear observation of neutron/gamma-ray pulse-shape sensitivity of a fully-instrumented 8 $\times$ 8 array of plastic scintillator segments coupled to two 5 cm $\times$ 5 cm 64-channel SiPM arrays as part of a study of…
A monitoring system for fast neutrons is planned in the COSINE experiment, a dark matter experiment with NaI crystals. We pursued several R&D approaches for a neutron detector using a liquid scintillator (LS). A pulse shape discrimination…
In this study, we evaluate and compare the pulse shape discrimination (PSD) performance of multipixel photon counters (MPPCs, also known as silicon photomultiphers - SiPMs) with that of a typical photomultiplier tube (PMT) when testing…
The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination (PSD) down to an electron-equivalent…
A series of test experiments on three different Si-based neutron detectors, namely a 1-d 128 channel, 0.5 mm space resolution Si microstrip sensor coupled to natural Gd converter, a medium size ? 1 cm2 PIN diode coupled to nGd2O3 or…
Pulse-shape discrimination (PSD) is usually achieved using the different fast and slow decay components of inorganic scintillators, such as BaF2, CsI:Tl, etc. However, LaBr3:Ce is considered to not possess different components at room…
Fast-neutron/gamma-ray pulse-shape discrimination has been performed for the organic liquid scintillators NE 213A and EJ 305 using a time-of-flight based neutron-tagging technique and waveform digitization on an event-by-event basis.…
We present a characterization of a small (9-liter) and mobile 0.1% 6Li-doped pulse-shape-sensitive plastic scintillator antineutrino detector called SANDD (Segmented AntiNeutrino Directional Detector), constructed for the purpose of…
Point-contact p-type high-purity germanium detectors (PPC HPGe) are particularly suited for detection of sub-keV nuclear recoils from coherent elastic scattering of neutrinos or light dark matter particles. While these particles are…
We report on the results of the positional-dependent pulse shape discrimination (PSD) parameter observed within a monolithic CLLB scintillation crystal. CLLB, a relatively novel inorganic scintillation crystal, is capable of PSD between…
Sufficient current pulse information of nuclear radiation detectors can be retained by direct waveform digitization owing to the improvement of digitizer's performance. In many circumstances, reasonable cost and power consumption are on…